ABB ACH580-BCR-125A-6+B058 HVAC Drive - UL Type 1/12/3R

Part Number: 3AUD0000004273
Manufacturer
ABB
Part number
3AUD0000004273

Quick Summary

ABB ACH580-BCR-125A-6+B058 HVAC drive delivers precise motor speed control for HVAC equipment. This solution addresses common integration challenges and downtime by providing a compact, reliable motor control platform for packaged systems. Key protections include UL-listed safety features and a NEMA Type 1/12/3R enclosure, plus electronic motor overload protection to safeguard motors and wiring in harsh environments. For installers and operators, the built-in ABB E-Clipse bypass, door-mounted control panel, and serial communications enable faster commissioning, easier diagnostics, and tighter control within industrial HVAC networks, delivering measurable energy efficiency and reduced maintenance costs over the life of the system.

Product Information

Extended Description

3AUD0000004273 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1, 12 or 3R enclosure with a bypass motor starter and is available from 1 to 350 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability
Feature: ABB E-Clipse bypass is integrated with a bypass motor starter. Benefit: Enables safe, convenient service without powering the load, reducing downtime during maintenance and swaps. Application: Commercial HVAC units and air-handling systems where uptime is critical. The E-Clipse bypass supports faster commissioning and improved component accessibility during routine servicing. Feature: Input disconnect switch or circuit breaker with door-mounted, interlocked operation. Benefit: Enhances safety and lockout capability for maintenance crews, meeting NEMA/UL expectations and reducing incident risk. Application: Field installations in industrial buildings where electrical code compliance and safe access are required. Feature: 1 to 350 hp range at 230/460/575 V with 125 Hp (125 A) nominal rating. Benefit: Provides scalable motor control for a wide range of HVAC motors, enabling standardization across multiple units and simplifying spare parts inventory. Application: Packaged HVAC drives for rooftops, air handlers, and large ventilation fans. Feature: Door-mounted control panel with graphical display and external control connections. Benefit: Simplified local control and remote integration, reducing commissioning time and enabling quick fault isolation. Application: Integrated systems where maintenance and diagnostics are performed on-site or via external controllers. Feature: Serial communications capability and robust protection features. Benefit: Facilitates integration with building automation and PLC networks, improving data visibility, fault reporting, and predictive maintenance. Application: Modern HVAC plants requiring networked monitoring and proactive asset management.

Get a Quick Quote for a ABB 3AUD0000004273

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3AUD0000004273? Enquire Now

FAQs

Installers should plan for a UL Type 1/12/3R enclosure installation with a door-mounted control panel and interlocked disconnect. Ensure proper alignment with the bypass starter and that external control connections are routed to compatible PLCs or building automation systems. The drive supports 230/460/575 V, enabling consistent procurement and wiring practices across multiple units.
The drive is rated for 125 Hp (125 A) at 230/460/575 V with a 1 to 350 Hp operating range. It includes electronic motor overload protection, an integrated E-Clipse bypass, and a bypass starter for serviceability. This combination supports reliable performance in commercial HVAC applications while enabling scalable implementation.
The E-Clipse bypass provides a safe, enclosed bypass path that allows motor servicing without removing power from the load. This reduces downtime, simplifies maintenance workflows, and improves safety by keeping the drive isolated while the bypass remains engaged for critical operations.
The ACH580-BCR-125A-6+B058 is designed for UL-listed protection with a NEMA Type 1/12/3R enclosure. This matters because it ensures regulatory compliance, safer maintenance access, and suitable protection for HVAC equipment operating in a range of environments, from controlled indoor spaces to tougher industrial facilities.
Expected ROI comes from reduced downtime due to the integrated bypass, improved motor protection, and easier commissioning. The drive’s compatibility with external controls and serial communications also lowers installation time and enables predictive maintenance approaches, ultimately reducing total cost of ownership over the system’s lifespan.