ABB 3AXD50000039030 Motors & Drives - IP21 Enclosure
Part Number: 3AXD50000039030
Quick Summary
ABB 3AXD50000039030 LV AC wall-mounted drive is designed for water and wastewater pumping applications. Engineers struggle with energy waste, pump wear, and complex control logic in municipal and industrial pump stations. The unit ships with an IP21 enclosure (IP55 option) and supports standard CE-marked electrical installations, delivering reliable protection and regulatory confidence. By enabling sensorless flow calculation, multipump control, level control, and dry-run protection, it helps optimize head and flow while reducing unnecessary starts. The Drive Composer PC tool and a handheld Hand-Off-Auto panel streamline commissioning and diagnostics, while documented energy calculations support ROI discussions with management. This combination of features translates into measurable efficiency gains and lower operating costs for water treatment and wastewater facilities.
Product Information
Extended Description
3AXD50000039030 ABB: The ACQ580-01 drives deliver innovative pump features for the water and wastewater industry, securing energy efficient flow of water and wastewater in your pumping solutions. This robust and compact wall-mounted drive has built-in pump application functionality such as sensorless flow calculation, multipump control, level control, soft pipe fill, dry run protection, quick ramps and a solution for keeping the impeller of the pump clean.
Usability is further enhanced with the intuitive Hand-Off-Auto control panel, the PC tool Drive composer and an optional Bluetooth=C2=AE control panel. The built-in energy calculator visualizes the energy savings achieved with the use of the drive. The ACQ580-01 variant comes in IP21 enclosure as standard and can be installed on the wall. Also, IP55 and flange mounting units are available.
Feature: Sensorless flow calculation and multipump control support precise regulation of pump head and flow, reducing energy use and wear. Business impact: lowers electricity costs and extends pump life, improving total cost of ownership for municipal and industrial pumping stations. Application: municipal water distribution and wastewater lift stations, where multiple pumps must be coordinated without external sensors. Feature: Level control, dry-run protection, soft pipe fill, and quick ramps enhance system reliability and protect pumps from damage during startup and changing head conditions. Business impact: fewer unscheduled outages, reduced maintenance, and longer impeller life. Application: basins, tanks, and pump houses where variable levels and intake conditions occur frequently. Feature: Built-in energy calculator and intuitive Hand-Off-Auto control with Drive Composer enable rapid commissioning and ongoing optimization. Business impact: accelerated project timelines, easier operator adoption, and clear ROI messaging to management. Application: new installations and retrofits across water and wastewater facilities. Feature: Integrated PC-based tooling and optional Bluetooth control panel support remote diagnostics and field updates. Business impact: faster service response, reduced on-site visits, and improved uptime. Application: remote plants and hard-to-reach installations. Feature: Compact wall-mounted design with IP21 standard enclosure and IP55 option, plus flange mounting compatibility, simplifies installation and serviceability. Business impact: minimal footprint in control rooms, easier retrofits, and versatile mounting options. Application: compact pump rooms and wall-adjacent control panels across treatment plants.
Get a Quick Quote for a ABB 3AXD50000039030
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3AXD50000039030?
Enquire Now
FAQs
This drive is designed for wall mounting with IP21 enclosure as standard (IP55 option available). Ensure a clean, ventilated electrical cabinet, proper cable routing to the 400 V supply, and compatible fieldbus or PLC interfaces. Use Drive Composer for configuration and confirm correct wiring diagrams in the installation manual to minimize startup time.
The unit delivers 18.5 kW with a nominal current around 38 A at 400 V. It is designed for LV mains and includes sensorless flow calculation, multipump control, level control, dry-run protection, and quick ramps to optimize pump start-stop cycles while protecting the system.
Yes. The drive supports multipump control and level-based sequencing, enabling coordinated operation of multiple pumps. This reduces energy spikes, improves head generation consistency, and simplifies supervisory control, which is particularly valuable in wastewater basins and lift stations.
The drive uses an IP21 enclosure by default with IP55 options available, aligning with common electrical protection standards for indoor pump rooms. While CE-marking is typical for electrical equipment, always verify regional regulatory labeling during procurement and installation to ensure full compliance.
Expected benefits include energy savings from optimized flow control, reduced pump wear due to soft starts and dry-run protection, and easier commissioning via Drive Composer and Hand-Off-Auto. The combination typically shortens project timelines, lowers maintenance visits, and provides a clear business case for upgrading aging pumping infrastructure.