ABB 3AXD50000706747 LV AC Wall-Mounted Drive - UL Type 1 Enclosure

Part Number: 3AXD50000706747
Manufacturer
ABB
Part number
3AXD50000706747

Quick Summary

ABB 3AXD50000706747 LV AC wall-mounted drive for water and wastewater applications delivers precise pump control. This solution tackles energy waste and variable flow challenges common in municipal and industrial pumping. It ships with UL Type 1 (and options for Type 12 or 3R enclosures) and includes a UL-approved electronic motor overload for safe, compliant installations. By integrating an energy calculator and a user-friendly hand-off-auto interface, it enables rapid ROI and streamlined asset management, while supporting Drive Composer PC tool adoption and optional Bluetooth control for remote diagnostics.

Product Information

Extended Description

3AXD50000706747 ABB: The ACQ580-PC drives deliver the ACQ580 Product Series features delivering innovative pump features for the water and wastewater industry, securing energy-efficient flow of water and wastewater in your pumping solutions. This robust and compact wall-mounted packaged drive has built-in pump application functionality such as sensorless flow calculation, multi-pump control, level control, soft pipe fill, dry run protection, quick ramps, and a solution for keeping the impeller of the pump clean. Usability is further enhanced with the intuitive Hand-Off-Auto control panel, the PC tool Drive composer, an optional Bluetooth=C2=AE control panel, and a UL-approved electronic motor overload. The built-in energy calculator visualizes the energy savings achieved with the use of the drive.=20 The ACQ580-PC Packaged Drive includes an ACQ580 Product Series drive inside a UL Type 1, 12 or 3R enclosure with either an input rotary circuit breaker disconnect switch and fast acting fuses (ACQ580-PC) that is pad lockable in the off position providing a 100K short circuit rating. It is available from 1 to 350 hp at 230/460/575 V.
Feature → Business Impact → Application: Sensorless flow calculation enables accurate pump head and flow estimation without external sensors, reducing instrumentation costs and improving energy efficiency in wastewater pumping. Application: municipal water treatment, lift stations, and industrial effluent handling. Feature → Business Impact → Application: Multi-pump control and level control optimize pump sequencing and tank levels, lowering idle running and maintenance frequency. Application: systems with multiple pumps or tanks in series/parallel configurations. Feature → Business Impact → Application: Dry run protection and quick ramps limit mechanical stress and water hammer, extending pump life and reducing repair costs. Application: high-start/stop cycles and surge-prone piping. Feature → Business Impact → Application: Soft pipe fill and impeller cleaning assistance minimize debris-induced wear and improve reliability in solids-laden streams. Application: wastewater pumping with variable solids content. Feature → Business Impact → Application: Built-in energy calculator visualizes savings and supports ongoing optimization, supporting compliance reporting and budgeting. Application: energy-management programs and plant optimization initiatives. Feature → Business Impact → Application: Intuitive Hand-Off-Auto panel, Drive Composer PC tool, and optional Bluetooth control panel simplify commissioning, remote monitoring, and updates. Application: field installations with limited expert support, or remote sites requiring maintenance agility.

Get a Quick Quote for a ABB 3AXD50000706747

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3AXD50000706747? Enquire Now

FAQs

This unit is designed for UL Type 1, Type 12, or Type 3R enclosures, with a pad-lockable disconnect and a 100K short circuit rating. For compatibility, ensure the control cabinet supports 230/460/575 V service, that wiring routes meet your plant’s safety standards, and that the Drive Composer PC tool or Hand-Off-Auto panel is available for commissioning. Grouping multiple drives for a shared control scheme is supported when loads are balanced and cable routing minimizes EMI.
Key specs include 1–350 hp at 230/460/575 V input, and sensorless flow calculation for pump performance optimization. The drive supports multi-pump control, level control, dry run protection, soft pipe fill, and quick ramps to minimize water hammer and mechanical stress. Built-in energy calculation helps quantify savings, while UL-listed overload protection adds a safety margin for harsh wastewater environments.
Yes. The ACQ580-PC packaged drive excels in multi-pump configurations due to its multi-pump control and level control functions. It enables coordinated sequencing, prevents simultaneous start-up surges, and maintains desired tank levels. This reduces energy waste, extends pump life, and simplifies control logic in lift stations and wastewater treatment stages.
The drive is designed for UL Type 1, with optional Type 12 or Type 3R enclosures and UL-approved electronic motor overload, supporting safe installation in industrial environments. It emphasizes protective features such as dry run protection and a robust short-circuit rating, aligning with typical plant safety programs and installer requirements for municipal and industrial facilities.
The integrated energy calculator documents potential energy savings from optimized pump operation, while sensorless control and protection features reduce wear, downtime, and maintenance costs. The intuitive operator interface and optional Bluetooth panel enable faster commissioning and remote troubleshooting, lowering on-site service time and accelerating payback in water/wastewater plants.