ABB 3AXD50001011123 Drive - UL Listed Ultra-Low Harmonic
Part Number: 3AXD50001011123
Quick Summary
ABB ultra-low harmonic drive for water and wastewater pumps optimizes energy‑efficient flow. Users struggle with harmonic distortion, expensive external filters, and maintenance downtime that erodes reliability. This UL listed drive features an IP21 enclosure by default, with IP55 and flange options for tougher environments. Built‑in pump features and a compact, wall‑mounted design simplify integration, while Drive Composer and Hand‑Off‑Auto control streamline operations. By reducing THDi to under 3% and providing sensorless flow calculation and multipump control, it lowers total cost of ownership and supports regulatory compliance, helping utilities and OEMs deliver reliable water pumping with lower lifecycle costs.
Product Information
Extended Description
3AXD50001011123 ABB: The ACQ580-31 drives deliver innovative pump features for the water and wastewater industry, securing energy efficient flow of water and wastewater in your pumping solutions. The ultra-low harmonic variant provides ultimate harmonic performance, reaching even less than 3 % THDi, and exceeding the requirements set by low harmonic standards and recommendations. The drive includes an active supply unit and integrated low harmonic line filter, meaning there is no need for external filters, multi-pulse arrangements or special transformers. Other features include output voltage boost and power factor correction. This robust and compact wall-mounted drive has built-in pump application functionality such as sensorless flow calculation, multipump control, level control, soft pipe fill, dry run protection, quick ramps and a solution for keeping the impeller of the pump clean. Usability is further enhanced with the intuitive Hand-Off-Auto control panel, the PC tool Drive composer and an optional Bluetooth=C2=AE control panel. The ultra-low harmonic wall-mounted variant comes in IP21 enclosure as standard. Also, IP55 and flange mounting units are available.
Feature: Ultra‑low harmonic design with integrated low harmonic filter → Business Impact: Eliminates need for external filters and complex multi‑pulse arrangements, reducing installation costs and cabinet space while improving electrical network quality → Application: Ideal for water and wastewater pumping where harmonic compliance and compact footprints matter. Long‑tail keywords: ultra-low harmonic drive, low harmonic line filter, THDi reduction, energy‑efficient pump drive. Feature: Built‑in sensorless flow calculation, level control, and multipump control → Business Impact: Improves process visibility, enables precise water level management, and enables coordinated multi‑pump operations reducing start‑stop cycles and energy waste → Application: Multi‑pump stations, water treatment basins, and lift stations. Long‑tail keywords: sensorless flow calculation, multipump control, level control, smart pump management. Feature: Dry run protection, soft pipe fill, and quick ramps → Business Impact: Minimizes dry running damage, prevents water hammer, and speeds startup for smoother system transitions → Application: Pump protection in wastewater facilities and municipal water systems. Long‑tail keywords: dry run protection, soft pipe fill, quick ramps. Feature: Hand‑Off‑Auto control panel, Drive Composer, and Bluetooth option → Business Impact: Enhances operator usability, simplifies commissioning, and enables remote monitoring and diagnostics → Application: Field service, automation integrations, and OEM deployments. Long‑tail keywords: Hand‑Off‑Auto panel, Drive Composer, Bluetooth control panel. Feature: IP21 standard enclosure with optional IP55 and flange mounting → Business Impact: Installation flexibility across plant layouts and harsher environments without additional enclosures → Application: Wall‑mounted drives in plant basements, outdoor enclosures, and retrofit projects. Long‑tail keywords: IP21 enclosure, IP55 option, wall‑mounted drive, installation flexibility. Feature: Output voltage boost and power factor correction → Business Impact: Improves motor performance, reduces system losses, and supports energy‑savvy plant design → Application: Water/Wastewater pumping where motor efficiency and grid compliance matter. Long‑tail keywords: power factor correction, output boost, motor efficiency.
Get a Quick Quote for a ABB 3AXD50001011123
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3AXD50001011123?
Enquire Now
FAQs
Start with power isolation and confirm supply voltage is 230 V. Mount the wall‑mounted drive on a suitable surface (IP21 enclosure by default). Connect the motor (up to 75 Hp) via the built‑in terminals, enable the integrated low harmonic filter, and configure sensorless flow calculation and multipump control in Drive Composer. Use the Hand‑Off‑Auto panel for operations and consider optional IP55 mounting if the environment requires it.
The ultra‑low harmonic variant delivers THDi below 3%, substantially reducing harmonic distortion in the network. This improves power quality, reduces risks of transformer and switchgear overheating, and minimizes the need for external filters, lowering installation and maintenance costs in water/wastewater pumping plants.
Yes. It includes multipump control and level control features, enabling coordinated operation of multiple pumps. Sensorless flow calculation provides accurate flow estimates without additional sensors, improving efficiency and reducing wear from unnecessary start‑ups in循 wastewater handling scenarios.
The drive is UL listed, comes in a standard IP21 enclosure, and offers optional IP55 and flange mounting. These certifications and options support regulatory compliance and installation flexibility across indoor and harsher environments in water and wastewater facilities.
Expect lower maintenance due to integrated filters and built‑in protections like dry run protection, plus energy savings from THDi reduction and improved motor efficiency via power factor correction. The result is reduced downtime, lower energy costs, and simpler commissioning with Drive Composer and remote monitoring options.