ABB 3GGA091010-ADDIN 3-Phase Squirrel Cage Motor - IE3

Part Number: 3GGA091010-ADDIN
Manufacturer
ABB
Part number
3GGA091010-ADDIN

Quick Summary

The ABB 3GGA091010-ADDIN is a 3-phase squirrel cage motor for rugged industrial drives such as pumps and conveyors. Users struggle with downtime in harsh environments, and this design addresses that with a robust cast-iron frame and IP55 protection. It achieves IE3 efficiency with IC411 insulation, aligning with energy and safety standards essential for modern plants. The motor’s reversible rotation, compact 90 frame, and IMB3 mounting make installation straightforward, while its India origin supports flexible supply chains and predictable lead times.

Product Information

ABB Type Designation
M2GAX 90SLA 2
Invoice Description
M2GAX 90SLA 2
Product Name
3-Phase squirrel cage motor
Product Type
IGA3_-_M2GAX_Non-sparking_IE3_cast_iron_motor
Made To Order
No
Minimum Order Quantity
1 piece
Order Multiple
1 piece
Selling Unit of Measure
piece
Country of Origin
India (IN)
Customs Tariff Number
85015220
Electrical Data
Temperature Class Default
T3
Altitude
1000 m
Ambient Temperature
50 °C
IC Class
IC411
IE Class Data (50 Hz)
IE Class IE3 | Full Load (100%) 85.9 % | Partial Load (75%) 86.7 % | Partial Load (50%) 85.8 %
IP Class
IP55
Insulation Class
ICLF
Direction of Rotation
Both sides
Number of Poles (High)
2
Two Speed Motor
No
Type of Duty
S1
Voltage Code
D
EX-Protection
Exec
Gas Group
IIC
Frame Material
Cast Iron
Frame Size
90
Bearing
6205-2Z/C3
Bearing NDE
6204-2Z/C3
IM Class
IMB3 IM1001
Terminator Box Location
D-End top
Package Level 1 Units
0 carton
Product Net Weight
26 kg
Gross Weight
29 kg
UNSPSC
26101100
Feature: Cast Iron frame and robust bearings (6205-2Z/C3, 6204-2Z/C3) → Business Impact: Increased durability and reduced replacement costs in vibration-prone installations. Application: Heavy-duty conveyors and pumps where uptime matters. Feature: IP55 protection with IC411 insulation and ambient 50 °C, altitude 1000 m → Business Impact: Reliable operation in dusty, hot, and high-altitude environments; lower maintenance intervals. Application: Outdoor or harsh plant areas. Feature: IE3 efficiency with Full Load 85.9% and Partial Loads around 85.8–86.7% → Business Impact: Energy savings and lower operating costs across variable loads. Application: Energy-intensive fans, pumps, and process equipment. Feature: Cast-iron frame, frame size 90, IM class IMB3 IM1001 → Business Impact: Stable mounting and easy retrofits in existing basements or machine spaces. Application: Standardized footprints in expanding facilities. Feature: Ex-protection (Exec) and Gas Group IIC → Business Impact: Compliance for hazardous-area installations; safer commissioning and ongoing operations. Application: Chemical, oil, and gas processing environments. Feature: Reversible rotation and D-End top terminator box → Business Impact: Flexible installation and simplified wiring; reduces field downtime. Application: Reversing drive layouts and tight electrical enclosures.

Get a Quick Quote for a ABB 3GGA091010-ADDIN

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3GGA091010-ADDIN? Enquire Now

FAQs

ABB 3GGA091010-ADDIN uses a 90 frame with IMB3 IM1001 mounting; the D-End top terminal box orientation facilitates easy wiring in tight spaces. Verify foot mounting alignment and shaft end clearance, and ensure compatible coupling and protective covers. The design supports standard IEC-compliant installations and quick retrofits in existing lines, minimizing downtime during upgrades.
IE3 efficiency for this motor is listed as 85.9% at Full Load (100%). At Partial Load, efficiency is 86.7% at 75% load and 85.8% at 50% load, indicating strong performance across a range of operating points. These figures translate to meaningful energy savings in variable-speed applications like pumps and fans when driven by appropriate VFDs.
The motor supports Ex-protection options (Exec) and Gas Group IIC, enabling safer operation in hazardous areas. For compliant installations, verify the applicable local standards and ensure proper enclosure rating, wiring, and testing per regulations. The combination of Ex protection and gas group rating helps reduce risk and simplify regulatory acceptance during audits.
IP55 protection provides protection against dust ingress and water jets, while ICFL insulation supports reliable operation at higher ambient temperatures. In dusty or damp environments, this combination reduces downtime from insulation or winding failures and extends service intervals. It also enables safer operation at higher ambient temperatures up to 50 °C.
Expect lower maintenance due to robust cast iron construction and durable bearings (6205-2Z/C3, 6204-2Z/C3) designed for vibration resistance. IE3 efficiency reduces energy costs over the motor’s life, improving ROI. Routine checks focus on bearing wear, terminal connections, and enclosure seals; alignment and coupling inspections help prevent early-stage faults.