ABB 3GGA222210-ADDIN 3-Phase Squirrel Cage Motor - IE3

Part Number: 3GGA222210-ADDIN
Manufacturer
ABB
Part number
3GGA222210-ADDIN

Quick Summary

ABB 3GGA222210-ADDIN 3-Phase Squirrel Cage Motor delivers reliable, energy-efficient drive for fans, pumps, and conveyors. Uptime and efficiency remain top concerns for plant engineers, especially in harsh environments where dust, moisture, or heat wear down equipment. This design meets IP55 protection, IE3 efficiency, and IC411 insulation, with temperature class T3 and altitude up to 1000 m, ensuring durable performance. Coupled with a cast iron frame and robust bearings, it delivers long service life while reducing energy costs; its IE3 class aligns with sustainability goals and lower operating expenses. For compatibility, it works with standard drives and controllers, streamlining procurement and maintenance for 4-pole, 225 frame configurations.

Product Information

ABB Type Designation
M2GAX 225SMA 4
Invoice Description
M2GAX 225SMB 8
Product Name
3-Phase squirrel cage motor
Product Type
IGA3_-_M2GAX_Non-sparking_IE3_cast_iron_motor
Made To Order
No
Minimum Order Quantity
1 piece
Order Multiple
1 piece
Selling Unit of Measure
piece
Country of Origin
India (IN)
Customs Tariff Number
85015230
Electrical Data
Temperature Class Default
T3
Altitude
1000 m
Ambient Temperature
50 °C
IC Class
IC411
IE Class Data (50 Hz)
IE Class IE3 | Full Load (100%) 93.9 % | Partial Load (75%) 94.2 % | Partial Load (50%) 93.8 %
IP Class
IP55
Insulation Class
ICLF
Direction of Rotation
Both sides
Number of Poles (High)
4
Two Speed Motor
No
Type of Duty
S1
Voltage Code
D
EX-Protection
Exec
Gas Group
IIC
Frame Material
Cast Iron
Frame Size
225
Bearing
6213-2Z/C3
Bearing NDE
6210-2Z/C3
IM Class
IMB3 IM1001
Terminator Box Location
D-End top
Package Level 1 Units
0 pallet (lift)
Product Net Weight
274 kg
Gross Weight
284 kg
UNSPSC
26101100
Feature: IE3 energy efficiency and 4-pole design. Business Impact: Lower energy consumption and reduced heat in continuous duty, translating to lower operating costs. Application: Ideal for pumps, fans, and conveyors in process industries where load varies. The motor’s efficiency also supports sustainability programs and utility incentives. Feature: Cast iron frame and 225 frame size. Business Impact: Enhanced mechanical strength and vibration resistance, delivering longer service life in rugged environments. Application: Heavy industry, steel, mining, and material handling where equipment durability matters. Feature: IP55 enclosure and IC411 insulation. Business Impact: Superior protection against dust and moisture, maintaining performance in dirty or outdoor installations. Application: Outdoor facilities, washdown areas, and dusty plants. Feature: Temperature and altitude tolerance. Business Impact: Reliable operation at ambient temperatures up to 50 °C and altitudes up to 1000 m, reducing the need for derating. Application: High-temperature plants and facilities at elevation. Feature: Ex protection option and Gas Group IIC compatibility. Business Impact: Enables hazardous-location installations with appropriate safety compliance, expanding application reach. Application: Chemical processing, paint booths, and other areas with potential explosive atmospheres. Feature: Bearing and IM class robustness. Business Impact: Reduced maintenance cycles and smoother starts, improving uptime. Application: High-load starts in packaging lines and centrifuges. Industry context and practical note: ABB’s IE3, cast-iron construction, and NDE bearing selection are aligned with common industry expectations for reliability and lifecycle costs in continuous operation environments. This combination supports predictable maintenance planning and a lower total cost of ownership over the motor life.

Get a Quick Quote for a ABB 3GGA222210-ADDIN

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3GGA222210-ADDIN? Enquire Now

FAQs

The 225 frame size suits standard industrial mounting plates and IMB3 IM1001 alignment; use the D-End top terminator box location for convenient wiring. Verify that the baseplate is flat and that shaft alignment and coupling fit within the 4-pole, 225 frame geometry. With IP55, ensure seals are intact and that the environment is within ambient and altitude specifications.
This motor features IE3 efficiency, a 4-pole configuration, and an IP55 enclosure. The voltage code is D, suitable for 50 Hz operation with a Full Load efficiency around 93.9% at 100% load and ~94.2% at 75% load. Duty is S1, with insulation class IC411 and a temperature rating of T3.
The specification includes Ex-Protection labeled Exec and Gas Group IIC, indicating an explosion-protected option for hazardous areas. Confirm local codes and regional approvals, and select the Ex-rated variant appropriate for your precise gas group and installation conditions.
IE3 efficiency typically reduces energy consumption compared with older IE2 designs, yielding lower operating costs over the motor’s life. When paired with proper drives and load profiles, users often experience meaningful energy savings, reduced heat loads, and maintenance advantages from a robust cast-iron frame and longer bearing life.
Ensure correct alignment and couplings for the 4-pole design, confirm bearing condition (6213-2Z/C3 with 6210-2Z/C3 as NDE), and maintain enclosure seals for IP55 protection. Monitor ambient temperature (up to 50 °C) and altitude (up to 1000 m), and perform regular insulation checks to sustain IC411 performance and overall reliability.