ABB 3GJA281230-ADCIN 3-Phase Motor - Exdb Flameproof
Part Number: 3GJA281230-ADCIN
Quick Summary
ABB 3GJA281230-ADCIN is a 3-phase squirrel cage motor designed for Exdb flameproof duty in hazardous industrial applications. Operators struggle with safety, regulatory compliance, and downtime in explosion-hazard zones. This motor meets Exdb flameproof protection, IP55 ingress protection, and IC411 insulation class, helping you satisfy stringent safety standards while maintaining performance. For system integrators and maintenance teams, ABB reliability translates to lower total cost of ownership, easier procurement, and predictable service life in harsh environments. In addition to its flameproof design, the IE2 efficiency profile supports energy reduction goals, and the compact frame size simplifies installation alongside compatible drives and protection components.
Product Information
ABB Type Designation
M2JAP 280SMC 2
Invoice Description
M2JAP 280SMC 2
Product Name
3-Phase squirrel cage motor
Product Type
IJA2__M2JAP_IE2_Flameproof_Exd_motor
Made To Order
No
Minimum Order Quantity
1 piece
Order Multiple
1 piece
Selling Unit of Measure
piece
Country of Origin
India (IN)
Customs Tariff Number
85015381
Electrical Data
Temperature Class Default
T4
Altitude
1000 m
Ambient Temperature
50 °C
IC Class
IC411
IE Class Data (50 Hz)
IE Class IE2 | Full Load (100%) 94.3 % | Partial Load (75%) 94.1 % | Partial Load (50%) 93.3 %
IP Class
IP55
Insulation Class
ICLF
Direction of Rotation
Both sides
Number of Poles (High)
2
Two Speed Motor
No
Type of Duty
S1
Voltage Code
D
EX-Protection
Exdb
Gas Group
IIB
Frame Material
Cast Iron
Frame Size
280
Bearing
6316/C3
Bearing NDE
6316/C3
IM Class
IMB3 IM1001
Terminator Box Location
D-End top
Package Level 1 Units
0 pallet (lift)
Product Net Weight
725 kg
Gross Weight
745 kg
UNSPSC
26101100
Exdb flameproof protection with an IP55 enclosure and IIB gas group rating delivers ignition-risk mitigation in hazardous zones. This combination minimizes safety incidents and supports regulatory compliance, reducing audit findings and unplanned downtime. It's ideal for chemical plants, refineries, and mining applications where explosive atmospheres demand robust protection and reliable performance. IE2 efficiency is realized with a precise 2-pole design and optimized winding geometry, translating to measurable energy savings across continuous operation. In Full Load, efficiency reaches approximately 94.3%, with 75% and 50% load figures around 94.1% and 93.3%, respectively. Lower energy consumption reduces operating costs and thermal load on power systems, improving overall plant profitability. Constructed with a Cast Iron frame (size 280) and precision bearings (6316/C3), this motor delivers rugged durability and stable operation under continuous duty (S1). The 2-pole design enables a compact form factor and predictable start/stop cycles, while IMB3 IM1001 mounting class supports standardized installation in industrial environments. The D-End top terminator box placement simplifies wiring and serviceability in tight control cabinets. Operational tolerance includes Temperature Class T4, ambient up to 50 °C, and altitude up to 1000 m, ensuring reliable performance in hot, high-altitude sites. With IP55 protection and IC411 insulation, insulation integrity is preserved under challenging ambient conditions, enhancing reliability and service life in demanding plants. The unit's dimensions and weight (725 kg net, 745 kg gross) reflect a robust, stationary installation. Designed for compatibility with standard drives, protection components, and hazardous-area accessories, it simplifies procurement and onboarding for project teams. The Indian origin and MRO-friendly bearings support long service life and predictable maintenance workflows.
Get a Quick Quote for a ABB 3GJA281230-ADCIN
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3GJA281230-ADCIN?
Enquire Now
FAQs
To install the ABB 3GJA281230-ADCIN in hazardous zones, ensure Exdb flameproof enclosure integrity, proper cable glands approved for Hazardous Locations, and correct grounding. Use compatible explosion-protected drives and protective accessories. Verify IP55 and IC411 insulation compliance during commissioning, and follow local electrical codes for hazardous-area installations to maintain certification validity.
At elevated ambient temperatures, the motor maintains IEC IE2 efficiency targets. Full-load efficiency is around 94.3%, with approximately 94.1% at 75% load and 93.3% at 50% load. These figures translate to meaningful energy savings in continuous operation and help control cooling loads in hot facilities without compromising output or reliability.
Yes. The model is specified for S1 duty, meaning continuous operation. Its flameproof Exdb protection, IP55 enclosure, and IC411 insulation are designed to sustain long-term reliability in explosive atmosphere environments. Pairing with appropriate drives and cooling solutions sustains steady performance, reduces thermal stress, and extends service life in demanding plants.
The motor provides Exdb flameproof protection, IP55 ingress protection, and IC411 insulation with a Gas Group IIB rating. It is designed for hazardous-area applications, maintaining regulatory compliance in chemical, oil & gas, and mining sectors. Temperature class T4 and ambient-temperature tolerance up to 50 °C further support safe operation under challenging conditions.
The IE2 efficiency rating reduces energy costs over the motor’s life, while rugged cast-iron framing and precision bearings support long service intervals. With a 725 kg net weight and 745 kg gross weight, it stays steady in fixed installations, lowering vibration-related wear. Combined, these factors yield lower maintenance costs and improved uptime in hazardous-area facilities.