ABB 3GJP402510-BDM Motor - Flameproof IE4 Exdb

Part Number: 3GJP402510-BDM
Manufacturer
ABB
Part number
3GJP402510-BDM

Quick Summary

ABB 3GJP402510-BDM Motor is a flameproof, IE4 motor for hazardous-area drives and heavy-duty process applications. Engineers increasingly struggle to combine safety compliance with high-efficiency operation under demanding ambient conditions. The unit features Exdb flameproof protection, IP55 enclosure, and IE4 efficiency, meeting essential IECEx/ATEX expectations for Zone 1/Division 1 environments. With 560 kW output at 400 V and 4-pole performance, it supports critical processes while maintaining reliable operation. In addition, its IMB5/IM3001 mounting compatibility and robust insulation (ICLF) reduce integration risk, while the 560 kW rating supports scalable plant modernization and lower total cost of ownership.

Product Information

Extended Description

3GJP402510-BDM ABB: Flameproof IE4 Super Premium Efficiency LV Motors, 560 kW, 400 V (3GJP402510-BDM)
ABB Type Designation
M3JP 400LA 4
Invoice Description
M3JP 400LC 4
Product Name
3-Phase squirrel cage motor
Product Type
3JP4__M3JP_IE4_Flameproof_Ex_db_motor
Made To Order
No
Minimum Order Quantity
1 piece
Order Multiple
1 piece
Selling Unit of Measure
piece
Country of Origin
Finland (FI)
Customs Tariff Number
85015394
Medium Description
560kW, 4P, Frame Size 400, 3 Phases, 400V, 50Hz, IP55 Enclosure, IMB5/IM3001 Mounting (3GJP402510-BDM)
Short Description
560kW, 4P, Frame Size 400, 3PH, 400V, 50Hz, IP55, IMB5/IM3001
Electrical Data
Connection Configuration
D
Temperature Class Default
T4
Input Voltage (Uin)
400 V
Frequency (f)
50 Hz
Output Power
560 kW
Altitude
1000 m
Ambient Temperature
40 °C
IC Class
IC411
IE Class Data (50 Hz)
IE Class IE4 | Full Load (100%) 96.7 % | Partial Load (75%) 96.6 % | Partial Load (50%) 96.0 %
IP Class
IP55
Insulation Class
ICLF
Direction of Rotation
Both sides
Number of Poles (High)
4
Two Speed Motor
No
Type of Duty
S1
Voltage Code
D
EX-Protection
Exdb
Gas Group
IIB
Frame Material
Cast Iron
Frame Size
400
Bearing
6324/C3
Bearing NDE
6319/C3
IM Class
IMB5 IM3001
Terminator Box Location
D-End top
Package Level 1 Units
0 pallet (lift)
Product Net Depth / Length
1891 mm
Product Net Height
1121 mm
Product Net Width
840 mm
Product Net Weight
3231 kg
Gross Weight
3271 kg
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
UNSPSC
26101100
Feature: Exdb flameproof protection provides a documented safety barrier in hazardous environments. Business Impact: Reduces risk of ignition sources, enabling safer operation of compressors, pumps, and fans in Zone 1/Division 1 facilities. Application: Oil & gas, chemical processing, and mining where fire and explosion protection are mandatory. Feature: IE4 super premium efficiency for large-scale electric motors. Business Impact: Delivers lower energy consumption and cooler running temperatures, translating to measurable energy cost reductions and smaller cooling loads. Application: Continuous process lines and pump trains requiring consistent efficiency at 400 V systems. Feature: IP55 enclosure and IC411 insulation class. Business Impact: Ensures protection against dust and water ingress while withstanding demanding ambient temperatures up to 40 °C, reducing maintenance cycles. Application: Outdoor installations and harsh plant locations with limited enclosure space. Feature: 4-pole, 560 kW output at 400 V with 50 Hz operation. Business Impact: Provides strong starting torque and reliable full-load performance for heavy-duty drives, supporting high-throughput processes. Application: Belt-driven fans, pumps, and conveyor systems in energy-intensive applications. Feature: Connection Configuration D and IMB5/IM3001 mounting. Business Impact: Simplifies electrical installation and ensures compatibility with standard base frames, accelerating commissioning. Application: Retrofit projects and new builds where existing D-configuration motors are specified, enabling quick migrations without major control-system changes. Feature: Robust mechanical build with Frame 400, Cast Iron frame, and durable bearings (6324/C3, 6319/C3). Business Impact: Extends service life in tough environments, reducing spare parts inventory and downtime. Application: Plants with high vibration, frequent starts, and long duty cycles. Feature: Ex-protected petrol/environmental suitability (Gas Group IIB). Business Impact: Supports compliance with hazardous-area gas classifications, ensuring safe operation under relevant ATEX/IECEx regimes. Application: Petrochemical refineries and chemical processing plants. Feature: Temperate design for S1 duty cycle and 400V networks. Business Impact: Delivers reliable continuous operation with predictable maintenance windows, improving plant uptime. Application: Continuous process lines, water treatment, and industrial automation systems.

Get a Quick Quote for a ABB 3GJP402510-BDM

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3GJP402510-BDM? Enquire Now

FAQs

For a D-configuration 400 V network, ensure correct wiring in delta or star as per ABB installation guidelines, verify voltage per phase around 400 V at 50 Hz, and confirm the Exdb flameproof housing meets site hazardous-area requirements. Use IMB5/IM3001 mounting and confirm proper alignment with Frame Size 400 to minimize vibration and wear in long-running operations.
The motor features Exdb flameproof protection, IP55 enclosure, IE4 efficiency, and IC411 insulation class, enabling safe operation in Zone 1/Division 1 or equivalent hazardous areas. It delivers 560 kW output at 400 V, 4-pole design, and a robust construction (Frame 400) to support heavy-duty drives with reliable cooling and long service life.
Ideal for oil and gas, chemical processing, mining, and other processing plants requiring flameproof protection and high efficiency. Applications include pumps, fans, compressor drives, and other critical 3-phase loads where safety and energy cost are primary concerns and 50 Hz, 400 V networks are standard.
Exdb flameproof protection, IP55 enclosure, and IE4 efficiency align with IECEx/ATEX expectations for hazardous environments. The motor also carries 4-pole, IMB5/IM3001 mounting and IC411 insulation, supporting compliance with industrial safety standards and safe integration into certified plant systems.
Expect reduced energy costs from IE4 efficiency and decreased downtime due to robust Exdb protection and IP55 enclosure. Adopt a preventive maintenance plan focusing on bearing life (6324/C3, 6319/C3), insulation health (ICLF), and mounting integrity (IMB5/IM3001). This approach shortens mean time between failures and extends service life for high-demand processes.