ABB 3GKP312220-AFL Flameproof IE3 Motor - IP55 Exdbeb
Part Number: 3GKP312220-AFL
Quick Summary
ABB 3GKP312220-AFL is a flameproof IE3 motor for hazardous-area industrial drives and pumps. In hazardous zones, safety compliance and energy costs are a constant concern for engineers. It carries Exdbeb explosion protection, IP55 enclosure, and IC411 insulation class, aligning with global safety and efficiency standards. As a premium-efficiency option for continuous-duty S1 applications, it reduces energy spend while delivering reliable IMB3/IM1001 mounting and rugged Finnish engineering. Built in Finland, this motor is engineered to withstand ambient temperatures up to 40 °C and operate at altitudes up to 1000 m, ensuring reliability across harsh sites. For procurement teams, the combination of standard 1 piece MOQ and direct replacement compatibility minimizes downtime and accelerates project timelines.
Product Information
Extended Description
3GKP312220-AFL ABB: Flameproof IE3 Premium Efficiency LV Motors, 110 kW, 500 V (3GKP312220-AFL)
ABB Type Designation
M3KP 315SMB 4
Product Name
3-Phase squirrel cage motor
Product Type
5KP3__M3KP_IE3_Flameproof_Exde_motor
Made To Order
No
Minimum Order Quantity
1 piece
Order Multiple
1 piece
Selling Unit of Measure
piece
Country of Origin
Finland (FI)
Customs Tariff Number
85015381
Medium Description
110kW, 4 Poles, Frame Size 315, 3 Phases, 500V, 50Hz, IP55 Enclosure, IMB3/IM1001 Mounting (3GKP312220-AFL)
Short Description
110kW, 4P, Frame Size 315, 3PH, 500V, 50Hz, IP55, IMB3/IM1001
Electrical Data
Connection Configuration
Y
Temperature Class Default
T4
Input Voltage (Uin)
500 V
Frequency (f)
50 Hz
Output Power
110 kW
Altitude
1000 m
Ambient Temperature
40 °C
IC Class
IC411
IE Class Data (50 Hz)
IE Class IE3 | Full Load (100%) 95.4 % | Partial Load (75%) 95.5 % | Partial Load (50%) 94.9 %
IE Class Data (60 Hz)
IE Class IE3 | Full Load (100%) 95.8 % | Partial Load (75%) 95.5 % | Partial Load (50%) 94.4 %
IP Class
IP55
Insulation Class
ICLF
Direction of Rotation
Both sides
Number of Poles (High)
4
Two Speed Motor
No
Type of Duty
S1
Voltage Code
F
EX-Protection
Exdbeb
Gas Group
IIB
Frame Material
Cast Iron
Frame Size
315
Bearing
6319/C3
Bearing NDE
6316/C3
IM Class
IMB3 IM1001
Terminator Box Location
D-End top
Package Level 1 Units
0 pallet (lift)
Product Net Depth / Length
1204 mm
Product Net Height
858 mm
Product Net Width
590 mm
Product Net Weight
946 kg
Gross Weight
966 kg
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
UNSPSC
26101100
Exdbeb flameproof protection enables safe operation in explosive atmospheres, reducing ignition risk in petrochemical, mining, and heavy-process plants. This motor’s robust flameproof construction supports reliable starts and stops in demanding environments, helping maintenance teams meet permit-to-work requirements. The Exdbeb rating, combined with gas-group IIB classification, provides a clear pathway to regulatory compliance while minimizing redesign during upgrades. In practice, operators gain safer, more predictable plant performance. IE3 premium efficiency at 110 kW, 500 V, and 50 Hz lowers energy consumption and operating costs in continuous-duty drives. IE Class data for 50 Hz shows full-load efficiency at 95.4%, with high-load performance around 95%; partial-load values remain above 94%. The 4-pole design in frame 315 provides strong torque characteristics for pumps and conveyors, while IMB3/IM1001 mounting simplifies installation and service in busy plants. IP55 enclosure plus IC411 insulation protect windings against dust and moisture, boosting reliability in dusty mills, chemical facilities, and offshore environments. The Y connection at 500 V simplifies wiring during retrofits, while the flameproof Ex protection and gas-group IIB rating satisfy common safety standards for hazardous-area motor solutions. Frame 315, with a net weight of 946 kg, delivers substantial inertia for demanding load profiles yet remains serviceable through IMB3/IM1001 mounting. Electrical specs support straightforward commissioning: Y connection at 500 V, 50 Hz, and voltage code F, with a D-End top termination box location that simplifies wiring access. The motor operates in ambient up to 40 °C and up to 1000 m altitude, making it suitable for global plants. Duty is S1, confirming suitability for continuous operation in demanding processes. From a procurement and installation perspective, ABB delivers a rugged, ready-to-install solution with frame 315, IMB3/IM1001 mounting, and a 1-piece minimum order quantity. The Finnish origin supports consistent quality and traceability, while the unit’s dimensions and weight (1204 mm x 858 mm x 590 mm; net 946 kg) inform crate design and handling. Overall, this motor provides reliability, safety, and energy efficiency for hazardous-area drives.
Get a Quick Quote for a ABB 3GKP312220-AFL
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3GKP312220-AFL?
Enquire Now
FAQs
Installation is simplified by using the D-End top termination box location and Y connection for 500 V 50 Hz wiring. With IMB3 IM1001 mounting and Exdbeb flameproof protection, the motor integrates with standard baseplates and supports straightforward service in hazardous zones, reducing commissioning time and permitting requirements.
Key specs include 110 kW output, 500 V input, 50 Hz frequency, 4 poles, IE3 premium efficiency, IP55 enclosure, Exdbeb flameproof protection, Y connection, voltage code F, and S1 duty. Operation is suitable from ambient 40 °C up to 1000 m altitude, ensuring broad applicability.
Yes. The ABB 3GKP312220-AFL features Exdbeb flameproof protection with gas-group IIB, IP55 enclosure, and IC411 insulation, meeting typical hazardous-area motor requirements and enabling safe operation in Zone-protected industrial plants.
IE3 premium efficiency at 110 kW and 500 V reduces energy consumption compared with older IE2 designs. Full-load efficiency is about 95.4% at 50 Hz, with high- and partial-load figures above 94%, delivering tangible energy savings and lower cooling loads in continuous-duty applications.
The motor uses IMB3 IM1001 mounting and a 315 frame, with a D-End top termination box for easy wiring access. At 946 kg net, it offers substantial inertia for heavy loads while remaining serviceable in harsh environments, aided by IP55 protection and Ex flameproof construction.