ABB 3GKP351810-AEG 3KP2__M3KP_IE2 Flameproof Exde
Part Number: 3GKP351810-AEG
Quick Summary
3GKP351810-AEG is a 3GKP351810-AEG? No, it is a 3GKP351810-AEG 3-phase squirrel cage motor designed for hazardous environments and heavy industry applications. Operators in explosive atmospheres struggle with safety, regulatory compliance, and downtime when motors fail or require frequent servicing. This model combines IP55 protection, Exde flameproof protection, and Exdb explosion protection for gas group IIB alongside IC411 insulation and IE2 efficiency, helping ensure compliant, reliable operation. By delivering robust construction and energy efficiency, it supports lower total cost of ownership while simplifying procurement and field installation for hazardous-area drives.
Product Information
Extended Description
3GKP351810-AEG ABB: (3GKP351810-AEG)
ABB Type Designation
M3KP 355LKA 2
Invoice Description
M3KP 355LKA 2
Product Name
3-Phase squirrel cage motor
Product Type
3KP2__M3KP_IE2_Flameproof_Exde_motor
Made To Order
No
Minimum Order Quantity
1 piece
Selling Unit of Measure
piece
Country of Origin
Finland (FI)
Customs Tariff Number
85015394
Electrical Data
Temperature Class Default
T4
Altitude
1000 m
Ambient Temperature
40 °C
IC Class
IC411
IE Class Data (50 Hz)
IE Class IE2 | Full Load (100%) 95.0 % | Partial Load (75%) 95.0 % | Partial Load (50%) 94.4 %
IP Class
IP55
Insulation Class
ICLF
Direction of Rotation
Both sides
Number of Poles (High)
2
Two Speed Motor
No
Type of Duty
S1
Voltage Code
E
EX-Protection
Exdbeb
Gas Group
IIB
Frame Material
Cast Iron
Frame Size
355
Bearing
6316M/C3
Bearing NDE
6316M/C3
IM Class
IMB3 IM1001
Terminator Box Location
Top
Package Level 1 Units
1 pallet (lift)
Product Net Weight
2350 kg
Gross Weight
2380 kg
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
UNSPSC
26101100 | 39120000
Flameproof Exde and Exdb protection deliver safer operation in Zone 1/2 atmospheres, reducing ignition risk and supporting regulatory compliance. Business impact: fewer unplanned shutdowns, lower incident risk, and improved maintenance planning; Application: chemical processing, petrochemical processing, mining, and other harsh-duty environments. IE2 efficiency with Full Load 95.0%, Partial Load 75%, and 50% loads translates to measurable energy savings and lower operating costs over the motor’s life; Application: continuous duty pumps, fans, and compressors where energy costs are a top concern. Cast Iron frame (355) with 6316M/C3 bearings and IMB3 IM1001 designation provides rugged durability for high-load applications; Business impact: extended service intervals, reduced bearing replacements, and improved downtime metrics; Application: heavy-duty pumps and conveyors in demanding facilities. IP55 enclosure, IC411 insulation class, ambient temperature up to 40 °C, altitude 1000 m ensure reliable performance in tough environments; Business impact: consistent performance in outdoor or heat-prone installations; Application: outdoor substations, remote processing facilities. Top terminator box location simplifies wiring, shortens installation times, and supports straightforward maintenance in constrained spaces; Business impact: faster commissioning and easier field service; Application: retrofit projects and new builds in hazardous zones. This motor’s 2-pole design and “S1” duty cycle align with standard industrial drives, improving compatibility with existing control systems and reducing integration risk; Application: plant-wide motor upgrade programs and new line equipment.
Get a Quick Quote for a ABB 3GKP351810-AEG
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3GKP351810-AEG?
Enquire Now
FAQs
For hazardous-area deployments, position the motor with the top terminal box accessible for wiring, ensure Exde flameproof protection with Exdbeb compliance, and verify the IP55 enclosure. The 355 frame and cast iron construction support rugged mounting in industrial spaces, while the gas group IIB rating informs enclosure and cabling requirements. Planning for outdoor or high-temperature sites helps prevent derating and downtime.
IE2 efficiency is rated at Full Load 95.0% with favorable partial-load performance (75% and 50%). This translates to lower running energy per unit of delivered output, reducing energy bills over the motor’s life. In continuous-duty applications like pumps and fans, the cumulative savings can be substantial, improving return on investment even when initial costs are higher for a flameproof design.
Yes. The motor features Exde flameproof protection and Exdb protection suitable for gas group IIB environments, addressing typical ATEX/IECEx containment needs. With an IP55 rating and IC411 insulation, it is designed to operate reliably in harsh zones while meeting essential safety and equipment standards required in chemical, oil & gas, and mining sectors.
The 355-cast-iron frame is paired with a top-location termination box for easier wiring. The bearing arrangement uses 6316M/C3 with IMB3 IM1001 class, supporting robust, low-maintenance operation under heavy loads. The two-pole, single-speed design suits standard industrial drives, enabling straightforward integration with existing control systems and retrofit projects.
With a durable cast-iron frame, high-quality bearings (6316M/C3), and robust insulation (ICLF), maintenance intervals can be extended, reducing downtime. The Exde/Exdb protection minimizes ignition-related risk, lowering insurance and downtime costs. Over time, energy savings from IE2 efficiency contribute to a favorable ROI in continuous or high-load applications such as pumps, fans, and conveyors.