ABB 3GKP353230-AEL IE3 Flameproof - Exdbeb
Part Number: 3GKP353230-AEL
Quick Summary
3GKP353230-AEL IE3 Flameproof LV motor delivers premium efficiency for hazardous-area drives in process industries. In real-world projects, reliability and safety in ATEX/IECEx zones demand motors that minimize downtime and maintenance. Key protections include Exdbeb flameproof protection for IIB gas group, IP55 enclosure, and IC411 insulation, supporting regulatory compliance and operator safety. With 250 kW of output at 500 V and IMB3/IM1001 mounting, this unit reduces energy costs while simplifying installation and service on tough-duty applications. Ideal for chemical processing, mining, and offshore operations, it pairs robust mechanical design with advanced electrical performance to meet demanding industrial standards.
Product Information
Extended Description
3GKP353230-AEL ABB: Flameproof IE3 Premium Efficiency LV Motors, 250 kW, 500 V (3GKP353230-AEL)
ABB Type Designation
M3KP 355SMC 6
Invoice Description
M3KP 355SMC 6
Product Name
3-Phase squirrel cage motor
Product Type
5KP3__M3KP_IE3_Flameproof_Exde_motor
Made To Order
No
Minimum Order Quantity
1 piece
Order Multiple
1 piece
Selling Unit of Measure
piece
Country of Origin
Finland (FI)
Customs Tariff Number
85015381
Medium Description
250kW, 6 Poles, Frame Size 355, 3 Phases, 500V, 50Hz, IP55 Enclosure, IMB3/IM1001 Mounting (3GKP353230-AEL)
Short Description
250kW, 6P, Frame Size 355, 3PH, 500V, 50Hz, IP55, IMB3/IM1001
Electrical Data
Connection Configuration
D
Temperature Class Default
T4
Input Voltage (Uin)
500 V
Frequency (f)
50 Hz
Output Power
250 kW
Altitude
1000 m
Ambient Temperature
40 °C
IC Class
IC411
IE Class Data (50 Hz)
IE Class IE3 | Full Load (100%) 95.8 % | Partial Load (75%) 96.1 % | Partial Load (50%) 95.8 %
IE Class Data (60 Hz)
IE Class IE3 | Full Load (100%) 95.8 % | Partial Load (75%) 95.8 % | Partial Load (50%) 95.1 %
IP Class
IP55
Insulation Class
ICLF
Direction of Rotation
Both sides
Number of Poles (High)
6
Two Speed Motor
No
Type of Duty
S1
Voltage Code
E
EX-Protection
Exdbeb
Gas Group
IIB
Frame Material
Cast Iron
Frame Size
355
Bearing
6322/C3
Bearing NDE
6316/C3
IM Class
IMB3 IM1001
Terminator Box Location
D-End top
Package Level 1 Units
0 pallet (lift)
Product Net Depth / Length
1479 mm
Product Net Height
968 mm
Product Net Width
700 mm
Product Net Weight
1849 kg
Gross Weight
1879 kg
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
UNSPSC
26101100
The IE3 premium efficiency rating delivers tangible energy savings across continuous-duty cycles, reducing operating costs and cooling requirements in pumps, fans, and conveyors. The business impact is lower total cost of ownership and improved sustainability metrics, especially in high-load applications where energy demand fluctuates. This motor’s Exdbeb flameproof protection for IIB gas groups enables safe operation in hazardous environments, translating into reduced risk profiles and simplified regulatory compliance for chemical plants and mining sites. Applications benefit from a robust IP55 enclosure and IC411 insulation, ensuring reliable performance under dust, moisture, and elevated ambient temperatures, while maintaining performance at altitude up to 1000 m. The D connection configuration and IMB3/IM1001 mounting compatibility support straightforward installation on existing bases, cutting integration time and minimizing commissioning costs. Frame size 355 and a cast-iron housing provide exceptional mechanical rigidity, supporting long service life in IMB3 IM1001 mounting schemes and demanding service intervals. The motor’s 6-pole design and 250 kW output suit heavy-duty drives such as crushers and kilns, with predictable startup torque and smooth speed control, even in tough operating conditions.
Get a Quick Quote for a ABB 3GKP353230-AEL
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3GKP353230-AEL?
Enquire Now
FAQs
The motor uses a D-configuration with IMB3 IM1001 mounting, and the terminal box is positioned at the D-End top for accessible wiring. Its Exdbeb flameproof protection and IIB gas-group rating make it suitable for hazardous zones, while the IP55 enclosure supports dust and moisture resilience during installation and operation.
This motor delivers 250 kW at 500 V with a 50 Hz supply, 6 poles, and a 3-phase configuration. It features IP55, insulation class ICLF, a D connection configuration, and a 1000 m altitude rating with ambient temperature up to 40 °C, aligning with demanding industrial requirements.
Yes. The Exdbeb flameproof protection for IIB gas groups, combined with IP55 enclosure and robust mechanical design, makes it appropriate for chemical processing, mining, and offshore facilities where hazardous atmospheres require certified equipment and reliable performance.
IE3 premium efficiency reduces electrical losses, lowering energy consumption and heat generation. This translates to cooler operation, extended bearing life, fewer unscheduled outages, and lower operating costs over the motor’s service life, especially in continuous-duty applications.
The unit is a standard model with a 1-piece minimum order quantity and is not made-to-order. Origin is Finland, and the product is offered in a ready-to-install configuration with a focus on quick commissioning in regulated environments; for precise lead times, contact the sales team with your project location.