ABB 3GKP403840-BDM Flameproof Motor - Exdbeb

Part Number: 3GKP403840-BDM
Manufacturer
ABB
Part number
3GKP403840-BDM

Quick Summary

Flameproof IE4 motor for heavy‑duty industrial drives in hazardous locations. In many plants engineers wrestle with ensuring safe operation while reducing energy costs and meeting strict ATEX/IECEx certifications. ABB’s 3GKP403840‑BDM delivers IE4 efficiency, IP55 protection and Exdbeb flameproof protection for gas group IIB, enabling reliable performance in harsh environments. The design is tailored for 400 V, 50 Hz power rails with IMB5/IM3001 mounting and D‑end top terminator, delivering straightforward installation and proven durability in heavy industry. With a robust cast‑iron frame and a compact 400 frame size, it supports long life in demanding duty cycles while helping you meet safety, maintenance and total cost of ownership goals.

Product Information

Extended Description

3GKP403840-BDM ABB: Flameproof IE4 Super Premium Efficiency LV Motors, 560 kW, 400 V (3GKP403840-BDM)
ABB Type Designation
M3KP 400LKD 6
Invoice Description
M3KP 400LKD 6
Product Name
3-Phase squirrel cage motor
Product Type
3KP4__M3KP_IE4_Flameproof_Ex_db_eb_motor
Made To Order
No
Minimum Order Quantity
1 piece
Order Multiple
1 piece
Selling Unit of Measure
piece
Country of Origin
Finland (FI)
Customs Tariff Number
85015394
Medium Description
560kW, 6P, Frame Size 400, 3 Phases, 400V, 50Hz, IP55 Enclosure, IMB5/IM3001 Mounting (3GKP403840-BDM)
Short Description
560kW, 6P, Frame Size 400, 3PH, 400V, 50Hz, IP55, IMB5/IM3001
Electrical Data
Connection Configuration
D
Temperature Class Default
T4
Input Voltage (Uin)
400 V
Frequency (f)
50 Hz
Output Power
560 kW
Altitude
1000 m
Ambient Temperature
40 °C
IC Class
IC411
IE Class Data (50 Hz)
IE Class IE4 | Full Load (100%) 96.6 % | Partial Load (75%) 96.6 % | Partial Load (50%) 96.1 %
IP Class
IP55
Insulation Class
ICLF
Direction of Rotation
Both sides
Number of Poles (High)
6
Two Speed Motor
No
Type of Duty
S1
Voltage Code
D
EX-Protection
Exdbeb
Gas Group
IIB
Frame Material
Cast Iron
Frame Size
400
Bearing
6324/C3
Bearing NDE
6319/C3
IM Class
IMB5 IM3001
Terminator Box Location
D-End top
Package Level 1 Units
0 pallet (lift)
Product Net Depth / Length
1891 mm
Product Net Height
1071 mm
Product Net Width
840 mm
Product Net Weight
3431 kg
Gross Weight
3471 kg
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
UNSPSC
26101100
Feature → Business Impact → Application: Flameproof Exdbeb protection with Gas Group IIB reduces risk and simplifies compliance in hazardous zones, enabling safer operation in chemical and petrochemical facilities. This translates to lower shutdowns and enhanced worker safety, particularly in ATEX/IECEx‑regulated environments. Feature → Business Impact → Application: IE4 efficiency at 560 kW lowers energy consumption and operating costs for continuous, S1 duty motors, delivering measurable savings in mining, refining, and metal processing plants. Feature → Business Impact → Application: IP55 enclosure and IC LF insulation protect against dust, moisture and temperature fluctuations, extending mean time between failures and reducing maintenance cycles in dusty or humid processes. Feature → Business Impact → Application: Cast‑iron frame (Frame Size 400) with IMB5/IM3001 mounting provides rugged durability and straightforward retrofits or OEM integrations in heavy industry. Feature → Business Impact → Application: 400 V, 50 Hz supply with 6 poles and D‑End top terminator simplifies wiring and installation, supporting quick commissioning and compatibility with existing drive systems in plant upgrades.

Get a Quick Quote for a ABB 3GKP403840-BDM

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3GKP403840-BDM? Enquire Now

FAQs

This motor features Exdbeb flameproof protection suitable for gas group IIB environments, IP55 ingress protection, and IMB5/IM3001 mounting. Ensure ATEX/IECEx compliance, proper enclosure sealing, and certified cable glands for Zone I/II installations. Verify connector and terminator access at the D-End top for safe serviceability.
The motor operates at 400 V, 50 Hz with an output of 560 kW and six poles. It is designed for continuous S1 duty, with IE4 efficiency and Ex protection. Ensure your drive topology supports 400 V systems and accommodate the 6‑pole speed profile for your process.
Yes. The Exdbeb flameproof protection, aligned with Gas Group IIB, is specified for hazardous locations. Confirm zone classification, installation standards, and local compliance requirements; integrate with certified enclosures and wiring practices to maintain compliance.
IE4 denotes Super Premium efficiency, reducing heat generation and energy consumption during long run times. In continuous duty applications, this can translate to lower operating costs, cooler equipment rooms, and improved overall system efficiency without compromising performance or torque characteristics.
Expect periodic inspection of the cast‑iron frame, bearings (6324/C3 and 6319/C3), and seal integrity in Ex environments. Maintain correct lubrication intervals, monitor insulation condition (ICLF), and verify the D‑End top termination access for safe maintenance. Plan for HP/drive alignment checks during routine outages to sustain reliability.