ABB 7BCEM3611T-BG Shaft Ground Motor - IE3 Premium

Part Number: 7BCEM3611T-BG
Manufacturer
ABB
Part number
7BCEM3611T-BG

Quick Summary

ABB Shaft Ground motor 7BCEM3611T-BG delivers reliable power for conveyors and fans in industrial automation. Engineers often confront challenges with efficiency, grounding reliability, and installation footprint in harsh factory environments. This design pairs IE3 Premium efficiency, NEMA design B characteristics, and a TEFC enclosure to meet regulatory expectations while preserving uptime. With a 182TC frame, dual voltage 230/460 V, and 3-phase operation, it simplifies wiring and reduces long-term energy costs. Shaft grounding improves electrical performance, and direct-on-line starting supports rapid startup without excessive inrush, delivering a compelling total cost of ownership for mechanical integrators and maintenance teams.

Product Information

Extended Description

7BCEM3611T-BG ABB: Shaft Ground 3 Hp 230 V (CEM3611T-BG)
Configuration Only
No
Country of Origin
United States (US)
Lead Time
0 day
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
EGAUT001EXPU
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
United States (US)
Lead Time
0 day
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
GBINS001EXPU
Warranty Return
Product under warranty must be returned
Country of Origin
United States (US)
Lead Time
0 day
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
SGIND004EXPU
Warranty Return
Product under warranty must be returned
Country of Origin
United States (US)
Lead Time
0 day
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
USABB014EXPU
Warranty Return
Product under warranty must be returned
ABB Type Designation
3HP,1760RPM,3PH,60HZ,182TC,3632M,TE
Ambient Temperature
40 °C
Bearing
6206 | Ball
Bearing NDE
6205 | Ball
Brake Present
No
Brand / Label
Baldor-Reliance
Catalog Number
CEM3611T-BG
Certification Agency
CSA | CSA EEV | UR
Country of Origin
United States (US)
Customs Tariff Number
85015220
Design
B
Dimension Diagram
36LYQ160: Dimension Sheet
Drive End Flange Type
C-Face
Duty Time
60 Min
ETIM 7
EC001851 - Electric motor
Efficiency Level
2015 Small Motor Standard | IE3 | Premium Efficiency (NEMA 12-12)
Electrical Data
Enclosure Type
TEFC
Frame Material
Steel
Frame Size
182
Frequency (f)
60 Hz
Global Commercial Alias
CEM3611T-BG
Gross Volume
7192.91 in³
Gross Weight
70 lb
Horsepower Rating UL/CSA
3.000 Hp
IDEA Granular Category Code (IGCC)
1318 >> Heating and cooling system motor AC
Insulation Class
H
Invoice Description
3HP,1760RPM,3PH,60HZ,182TC,3632M,TEFC,F1
Made To Order
No
Medium Description
Shaft Ground, 3 HP, 1800 RPM, Frame Size 182Tc, C-Face Mounting, 3 Phase, TEFC Enclosure, 230/460 V, 60 Hz (CEM3611T-BG)
Minimum Order Quantity
1 piece
Motor Base Type
Foot Mounted
Motor Frame Size
182TC
Motor Frame Suffix
TC
Mounting Orientation
Horizontal
Mounting Position
F1
NEMA Design Code
B
Number of Phases
3
Number of Poles
4P
Number of Poles (High)
4
Number of Speeds
Single Speed
Order Multiple
1 piece
Output Power
3 Hp
Power Factor
75 %
Product Name
Shaft Ground
Product Net Depth / Length
26.625 in
Product Net Height
16.25 in
Product Net Weight
70 lb
Product Net Width
16.625 in
Product Type
Undefined
Quote Only
No
Rated Current (In)
8.4 A | 4.2 A
Rated Efficiency
89.50 %
Rated Speed
1760 r/min
Selling Unit of Measure
piece
Service Factor
1.15
Service Factor Percentage
1.15 %
Shaft Diameter
1.13 in
Shaft Grounding
Shaft Grounding
Short Description
3 HP, 1800 RPM, Frame Size 182Tc, C-Face, 3 PH, TEFC, 230/460 V
Standards
NEMA
Starting of Motor
Direct On Line
Stocked At (Warehouses)
China | Alabama, United States | Alaska, United States
Synchronous Speed (vsyn)
1800 r/min
Type of Duty
Continuous
UNSPSC
26101105
Voltage Rating
230 V | 460 V
Feature → Business Impact → Application: The motor delivers IE3 Premium efficiency, reducing energy consumption and operating costs for continuous-duty drives such as conveyors and feeders. This translates to measurable ROI in high-cycle applications and helps facilities meet sustainability targets while maintaining reliable torque at 1760 r/min. Feature → Application: TEFC enclosure provides dust and moisture resistance, enabling installation in harsh environments without requiring elaborate housing. This is ideal for material handling, HVAC fans, and pump drives where cleanliness and protection are essential. Feature → Application: 182TC frame with a 1.13 in shaft and 3P configuration supports straightforward replacement in legacy systems and compatibility with standard motor starters, minimizing downtime during retrofits. Feature → Application: 0 day lead time and US stock at multiple warehouses ensure rapid deployment for critical line upgrades, reducing project delays. Feature → Application: Shaft grounding and robust bearings (6206/6205 Ball) improve grounding reliability and service life, lowering maintenance costs and frequency of bearing replacement. Feature → Application: Direct On Line starting and 3-phase operation deliver predictable performance in existing control schemes, supporting a smooth integration with existing VFDs or starter cabinets. Feature → Application: Continuous duty (Type: Continuous) with 60 Hz operation ensures consistent torque and cooling under normal operating conditions, suitable for fans and conveyors in manufacturing lines. Feature → Application: Insulation class H and NEMA design B compatibility provide compliance with industry standards while delivering durable performance in thermal cycling environments. Feature → Application: Shaft ground capability (Shaft Grounding) reduces electrical noise and potential stray currents, enhancing system reliability in sensitive automation cells and robotic workstations.

Get a Quick Quote for a ABB 7BCEM3611T-BG

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 7BCEM3611T-BG? Enquire Now

FAQs

Begin by confirming the mounting footprint and shaft diameter (182TC, 1.13 in shaft). Use the C-Face mounting with foot-mounted orientation (horizontal, Position F1). Ensure the terminal wiring matches 230/460 V, 3-phase supply and set the starter for Direct On Line operation. Check that the bearings (6206/6205) and TEFC enclosure are appropriate for the environment, and verify that the service factor (1.15) and rated current meet your load. Finally, test run at no-load then load with standard protection and torque checks.
This motor is a 3 HP, 1760 r/min, 60 Hz, 3-phase unit with dual voltage 230 V / 460 V. It uses an IE3 Premium efficiency class, insulation class H, and a service factor of 1.15. The frame size is 182TC, and the enclosure is TEFC. Starting method is Direct On Line, with a rated current of 8.4 A at full load and 4.2 A at reduced torque, suitable for steady industrial drives.
Yes. The continuous-duty rating, NEMA design B configuration, TEFC enclosure, and 3-phase, 60 Hz operation are optimized for reliability in conveyors and fans. The shaft grounding feature reduces electrical noise, while the IE3 efficiency reduces energy costs. Its 182TC footprint allows straightforward substitution in compatible systems, with robust bearings and a 1.15 service factor to handle moderate overloads common in material handling.
The motor carries CSA, CSA EEV, and UR (UL Recognized) approvals, with NEMA design compatibility and a TEFC enclosure suitable for rugged environments. These certifications support compliance in North American facilities and help simplify supplier qualification, electrical code adherence, and validation for critical process equipment used in automated plants.
Maintenance is simplified by the TEFC enclosure, robust 6206/6205 ball bearings, and shaft grounding which minimizes electrical fault exposure. The IE3 Premium efficiency reduces energy costs over the motor’s life, contributing to a favorable ROI, especially in applications with frequent duty cycles like conveyors and fans. Routine checks should include bearing lubrication intervals, insulation condition, and wiring integrity at the terminal box.