ABB 7BCM7010A LV Explosion Proof Motors - XPFC Enclosure
Part Number: 7BCM7010A
Quick Summary
LV Explosion Proof Motors from ABB provide safe, reliable, high-efficiency power for hazardous-area applications like chemical plants and refineries. Operators face uptime challenges and costly downtime in explosion-risk environments when using non-certified equipment. Critical certifications include XPFC-enclosed design, IP54 protection, and compliance with explosion-proofs standards to meet safety and regulatory requirements. Designed for 60 Hz, 3-phase operation with a 56C frame, these US-made motors help reduce lifecycle costs and simplify procurement. The 460 V rating supports standard industrial power distribution, while the XPFC design enables safe operation in enclosed spaces. With a regreasable bearing and robust 56C frame, maintenance cycles are predictable, translating into lower total cost of ownership and less unexpected downtime.
Product Information
Extended Description
7BCM7010A ABB: LV Explosion Proof Motors 460 V (CM7010A)
Country of Origin
United States (US)
Lead Time
0 day
Made To Order
No
Product Sales Status
Inactive
Quote Only
No
Warranty Return
Product under warranty must be returned
Country of Origin
United States (US)
Lead Time
0 day
Made To Order
No
Product Sales Status
Inactive
Quote Only
No
Warranty Return
Product under warranty must be returned
ABB Type Designation
.75HP,1725RPM,3PH,60HZ,56C,X3420M,X
Invoice Description
.75HP,1725RPM,3PH,60HZ,56C,X3420M,XPFC
Product Name
LV Explosion Proof Motors
Product Type
Undefined
Made To Order
No
Minimum Order Quantity
1 piece
Order Multiple
1 piece
Selling Unit of Measure
piece
Country of Origin
United States (US)
Customs Tariff Number
85015100
Replaced Product ID (OLD)
7B34-5329-5721
Stocked At (Warehouses)
China
Medium Description
Frame Size 56C, 3 Phase, XPFC Enclosure, (CM7010A)
Short Description
Frame Size 56C, 3 PH, XPFC,
Electrical Data
Temperature Class Default
--
Frequency (f)
60 Hz
Altitude
1000 m
Ambient Temperature
40 °C
IC Class
XPFC
IE Class Data (50 Hz)
IE Class NA
IE Class Data (60 Hz)
IE Class NA
IP Class
IP54
Insulation Class
ICLB
Direction of Rotation
Both sides
Two Speed Motor
No
Type of Duty
S1
Voltage Code
K
EX-Protection
ClassI
Frame Material
Steel
Frame Size
56
Bearing
6203
Bearing NDE
6203
Lubrication
Regreasable
IM Class
F1
Product Net Depth / Length
16.5 in
Product Net Height
11.375 in
Product Net Width
11.75 in
Product Net Weight
34 lb
Gross Weight
34 lb
Standards
NEMA
UNSPSC
26101112
Explosion-proof design is integrated through XPFC enclosure, delivering a certified barrier against ignition sources in hazardous areas. This translates to lower risk, easier compliance audits, and safer operation for motors used in chemical processing, oil and gas facilities, and refineries. For installation, the 56C frame and 3-phase, 60 Hz, 460 V electrical configuration fit standard industrial power systems, enabling quick integration with existing drives and switchgear. IP54 ingress protection and an insulation class ICLB build extend service life in dusty or humid environments. The robust frame and bearings (6203) are designed for steady performance under typical plant temperatures, reducing unscheduled repairs and improving uptime in demanding applications. Regreasable lubrication supports extended lubrication intervals, which lowers maintenance labor costs and minimizes downtime during service windows. This is especially valuable for remote locations or offshore facilities where maintenance windows are limited, ensuring consistent torque and performance. 0 day lead time and US-origin sourcing simplify procurement planning and traceability for quality-conscious buyers. Although the product is currently inactive in some channels, its engineering data supports seamless qualification in bid packages and spec sheets for hazardous-location motors. Compatibility with standard 56C frame motors, pulleys, and couplings reduces replacement risk and accelerates retrofits. The 34 lb weight and compact dimensions help with handling, shipment, and installation in tight spaces, contributing to faster project delivery and lower total cost of ownership.
Get a Quick Quote for a ABB 7BCM7010A
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 7BCM7010A?
Enquire Now
FAQs
Installers should verify the 56C frame compatibility and use 460 V three-phase electrical connections designed for 60 Hz operation. Ensure XPFC enclosure is properly sealed to maintain IP54 protection. Align shaft and couplings, secure input/output terminals, and integrate with standard drive hardware. The motor’s 34 lb weight aids handling in constrained spaces, reducing installation risks.
Key specs include 460 V, 60 Hz, three-phase operation, and a 56C frame. The motor uses IP54 protection and Insulation Class ICLB, with a Class I EX-Protection designation. The bearing is 6203 with regreasable lubrication, and the enclosure is XPFC. These factors together support reliable torque delivery, predictable startup, and robust operation in hazardous environments.
Yes. The XPFC enclosure provides explosion-proof protection, IP54 ingress protection, and Class I EX-Protection, making it suitable for chemical processing and similar hazardous locations. With a 60 Hz, 460 V, 3-phase configuration and a 56C frame, it integrates with common industrial power systems and motor-driven equipment in such facilities.
Certifications include XPFC explosion-protection, IP54 ingress protection, and Class I EX-Protection, aligning with industry safety standards. The motor also references NEMA standards via its external classification. These features simplify regulatory qualification, site audits, and supplier qualification in projects requiring hazardous-location equipment.
Regreasable lubrication reduces maintenance frequency and labor costs, while the 6203 bearing design supports durability in harsh environments. The 0 day lead time and US-origin sourcing streamline procurement, reducing scheduling risk and downtime. Overall, these factors contribute to lower total cost of ownership and improved uptime in hazardous settings.