ABB 7GSP008658R0006 Motor Starter - UL/cUL E1811

Part Number: 7GSP008658R0006
Manufacturer
ABB
Part number
7GSP008658R0006

Quick Summary

ABB 7GSP008658R0006 Motor Starter provides reliable AC switching for three-phase motors in control panels. Facing tight spaces and complex wiring, engineers need compact, easy-to-install solutions that reduce field setup time. This unit uses encapsulated coils for fast service and a smaller footprint without sacrificing performance in demanding environments. With UL/cULus E1811 safety certification and UL-listed recognition, along with ETIM EC000066 classification for power contactors, and WEEE category guidance, it aligns with modern regulatory expectations. Its 3P design with a NEMA Type 1 enclosure fits standard panel environments, while offering versatile coil options and open or enclosed configurations. The combination delivers improved uptime and lower lifecycle costs for industrial motor control applications.

Product Information

Extended Description

7GSP008658R0006 ABB: 300 series full-voltage contactos & motor controllers has encapsulated coils. Availilbe in size 00-9, open or NEMA Type 1,12,3R, 4X enclosures and toolless contactor disassembly.
REACH Information
False - does not contain substances > 0.1 mass percentage
Minimum Order Quantity
1 EA
Product Net Width
7.38 in
Product Net Height
6.13 in
Product Net Depth / Length
13.25 in
Product Net Weight
13 lb
Package Level 1 Units
1 piece
Package Level 1 Width
8.25 in
Package Level 1 Height
8.25 in
Package Level 1 Depth / Length
16 in
Package Level 1 Gross Weight
14.36 lb
Number of Poles
3P
Enclosure Type NEMA
Type1
cULus Certificate
E1811
Declaration of Conformity - CCC
No certification needed
Declaration of Conformity - UKCA
No certification needed
UL Certificate
E1811
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B
Business To Business
CN8
8536490065
UNSPSC
39121529
eClass
V11.1 : 27371003
Encapsulated coils in the ABB 7GSP008658R0006 motor starter deliver consistent actuation under vibration and temperature swings. By isolating the coil from field contaminants and reducing arc quenching requirements, the design improves MTBF and lowers service calls in busy control rooms. This makes it well-suited for high-demand machine controls in packaging lines, material handling, and general industrial automation where uptime matters. 3P operation and 115-230V dual wind wiring support flexible supply scenarios. The compact footprint reduces panel depth and allows easier multi-device mounting, while maintaining reliable acceleration and stopping of three-phase motors. Engineers can swap coil options across a range of sizes (00-9) without reworking the control schema, delivering faster commissioning and less downtime. Open or NEMA Type 1 enclosures meet common panel standards, with options for 12, 3R, or 4X as needed. This flexibility simplifies retrofit projects and new installations alike, particularly in tight control cabinets where space is at a premium. The module's 7.38 in width, 6.13 in height, and 13.25 in depth optimize mounting layouts for standard MCCs and panelboards. Tool-less contactor disassembly speeds maintenance and reduces the risk of damage during field service. Combined with encapsulated coils, this design minimizes spare parts usage and inventory costs. In practice, technicians can diagnose coil or contact issues quickly, which shortens downtime during start-up tests and routine checks. This product is certified to UL/cUL E1811 and aligned with ETIM EC000066, WEEE category 5 requirements, supporting regulatory compliance across regions. For procurement, the 1 EA minimum order quantity and packaging details streamline stocking and reorder planning in multi-site operations.

Get a Quick Quote for a ABB 7GSP008658R0006

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 7GSP008658R0006? Enquire Now

FAQs

Install the 3-pole starter in a suitable NEMA Type 1 or equivalent enclosure, wire the 115-230V dual wind coil to the control circuit, and use the 1 piece per package packaging to ensure proper fit. Take advantage of the toolless contactor disassembly for quick field checks and maintenance.
The unit supports 115-230V dual wind operation with encapsulated coils. Sizes range across 00 to 9, allowing you to adapt coil configurations without redesigning control wiring, which speeds up commissioning and reduces panel rework.
Yes. With a 3P configuration and NEMA Type 1 enclosure, it is well-suited for machine controls in conveyors and pump applications. The UL/cUL E1811 certification and ETIM EC000066 classification ensure it meets common industrial safety and performance standards.
This ABB starter carries UL/cUL E1811 safety certification, UL listing, ETIM EC000066 classification for power contactors, and WEEE category 5 guidance. These certifications aid regulatory compliance in NA and EU regions, streamline procurement, and support responsible end-of-life disposal.
Tool-less disassembly reduces maintenance time and risk of damage during service, while encapsulated coils improve resistance to dust and moisture. Combined, these factors shorten downtime, lower spare parts costs, and deliver a lower total cost of ownership in high-volume automation environments.