ABB 7GSP022817R0006 Motor Starter - Type3R NEMA

Part Number: 7GSP022817R0006
Manufacturer
ABB
Part number
7GSP022817R0006

Quick Summary

7GSP022817R0006 is ABB's 408 Combo Starter, a full-voltage motor control solution for single-speed induction motors up to 400 hp at 600 V. This integrated unit simplifies installation by combining starting, protection, and enclosure in one housing, reducing wiring and panel footprint. A common pain point is field wiring complexity and miswiring that leads to downtime; this design mitigates that risk with verified protection options and clear labeling. The assembly carries UL and cULus certifications (E1811) and is built to NEMA Type 3R standards for outdoor or semi-outdoor installations. By delivering a compact, compliant solution, it supports faster commissioning and easier maintenance, while compatibility with MCP and standard fuses improves overall reliability.

Product Information

Extended Description

7GSP022817R0006 ABB: Combination, Full-Voltage Motor Starter for single-speed induction motors for upto 400hp, 600V. Provide short Circuit protection by fuse, circuit breaker or MCP.
REACH Information
False - does not contain substances > 0.1 mass percentage
Minimum Order Quantity
1 EA
Product Net Width
11 in
Product Net Height
11.19 in
Product Net Depth / Length
28.75 in
Product Net Weight
20 lb
Package Level 1 Units
1 piece
Package Level 1 Width
12 in
Package Level 1 Height
12 in
Package Level 1 Depth / Length
30 in
Package Level 1 Gross Weight
20 lb
Number of Poles
3P
Enclosure Type NEMA
Type3R
cULus Certificate
E1811
UL Certificate
E1811
ETIM 8
EC000225 - Control circuit devices combination in enclosure
ETIM 9
EC000225 - Control circuit devices combination in enclosure
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
WEEE B2C / B2B
Business To Business
CN8
85365040
UNSPSC
39121521
eClass
V11.1 : 27371216
Feature: 3-pole full-voltage motor starter handles single-speed induction motors up to 400 horsepower at 600 volts. Business Impact: Directly drives motor loads with integrated protection, reducing the need for separate starters and wiring, which lowers installation time and potential miswiring. Application: ideal for conveyors, pumps, and machine tools where compact, reliable control is essential. Feature: Integrated protection by fuse, circuit breaker, or MCP. Business Impact: Flexible short-circuit protection improves safety and uptime, while reducing the number of external components and maintenance points. Application: panel builders and maintenance teams seeking streamlined, auditable protection schemes. Feature: NEMA Type3R enclosure for outdoor/semi-outdoor usage. Business Impact: Weatherproof and corrosion-resistant housing supports reliable operation in harsh environments, simplifying outdoor installations. Application: outdoor equipment, remote plants, and process lines. Feature: Certifications and standards (UL/cULus E1811, ETIM EC000225). Business Impact: Regulatory compliance accelerates procurement, audits, and project approvals, reducing risk across regulated industries. Application: manufacturing, food and beverage, and chemical processing sectors. Feature: Compact weight and dimensions with packaged Level 1 units. Business Impact: Easier site planning, safer handling, and faster installation in crowded control rooms. Application: system integrators designing compact motor control panels.

Get a Quick Quote for a ABB 7GSP022817R0006

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 7GSP022817R0006? Enquire Now

FAQs

Installation with existing panels is straightforward; the 3P full-voltage starter is designed for single-speed motors up to 600 V and up to 400 hp. Connect line, load, and control circuits per the included labeling; utilize built-in protection with a fuse, circuit breaker, or MCP. Ensure panel space accommodates the Type3R enclosure and verify access for maintenance.
Key performance specs include a 3P configuration, 600 V operation, up to 400 hp capacity, and full-voltage control. The unit is a combo starter with integrated protection and a NEMA Type3R enclosure, enabling reliable outdoor performance. Compatibility with standard fuses, circuit breakers, or MCP provides flexible protection aligned with safety standards.
Yes, the NEMA Type3R enclosure supports outdoor or semi-outdoor install locations, offering weather resistance and safe operation. While it is not a dedicated washdown IP-rated device, ensure proper environmental controls and placement. Verify ambient conditions and enclosure compliance for your plant's regulatory requirements.
Certified UL and cULus under E1811 verify safe operation and electrical protection, while ETIM EC000225 classifies it as a control circuit device combination in enclosure. These certifications simplify supplier qualification, enable regulatory audits, and help prevent project delays, particularly in industries with strict safety and interoperability standards.
By consolidating starting, protection, and enclosure, maintenance becomes simpler and faster. Fewer components mean less wiring, reduced panel space, and quicker commissioning, which lowers installation labor costs and downtime. The integrated solution also improves fault clarity and replacement speed, delivering measurable uptime gains over scattered starters and auxiliary protection devices.