ABB 7TBA050280R0044 Meter Sockets - Weatherproof Type 3R CSA 27716

Part Number: 7TBA050280R0044
Manufacturer
ABB
Part number
7TBA050280R0044

Quick Summary

ABB 7TBA050280R0044 Meter Sockets are designed to safely house metering in overhead and underground installations. Upgrading legacy meters often reveals compatibility gaps and unreliable field connections, which this unit helps mitigate with robust construction and a CT provisioning option. This product aligns with CSA 27716 certification and is housed in a Weatherproof Type 3R enclosure to withstand outdoor environments, supporting reliable service in harsh conditions. In addition, the 400 A, 120/240 V single-phase rating complements industrial power management strategies, while continuing to support efficient procurement and installation workflows for electrical distributors and engineers alike.

Product Information

Extended Description

7TBA050280R0044 ABB: JS4 underground 5 jaw meter socket configuration equipped with automatic circuit closing device. Provision only for current transformer.
EAN
0624871033822
UPC
624871033822
Replacement Product ID (NEW)
7TBA050280R0070
Country of Origin
Canada (CA)
Selling Unit of Measure
each
Package Level 1 Units
1 piece
Application
For overhead/underground installation
Brand / Label
Microlectric
Current Rating
400 A
Effective Date
19961217
Enclosure Type
Weatherproof Type 3R
Number of Phases
1 Phase
Product Name
METER SOCKETS
Product Type
Meter Sockets
Standards
CSA 27716
Voltage Rating
120/240 V
Data Sheet, Technical Information
JS4A-T
UNSPSC
39121102
WEEE Category
Product Not in WEEE Scope
IDEA Granular Category Code (IGCC)
4326 >> Test Block Bypass Meter Sockets
Feature: 400 A current rating and 120/240 V single-phase operation. Business Impact: Enables safe, high-capacity metering for commercial and light industrial loads, reducing the need for multiple enclosures. Application: Ideal for overhead or underground service upgrades where CT-based metering is planned. Feature: Underground 5 jaw meter socket configuration with automatic circuit closing device. Business Impact: Improves fault isolation and faster restoration, lowering outage costs. Application: Underground installations in mixed-use facilities requiring rapid circuit closure. Feature: Provision for current transformer (CT) integration. Business Impact: Supports CT-based metering schemes without rework, lowering installation time and risk. Application: Metering for higher-accuracy electrical accounting. Feature: Weatherproof Type 3R enclosure. Business Impact: Delivers superior outdoor durability and weather resistance, reducing field maintenance. Application: Outdoor utility and building service entrances. Feature: Brand Microlectric and CSA 27716 compliance. Business Impact: Ensures regulatory alignment and trusted performance across jurisdictions, simplifying compliance documentation. Application: Cross-border projects and controlled environments where standards adherence matters.

Get a Quick Quote for a ABB 7TBA050280R0044

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 7TBA050280R0044? Enquire Now

FAQs

For overhead and underground metering, ensure the system conductor sizing and protective devices align with a 400 A rating and 120/240 V single-phase supply. Use the 5 jaw configuration with the automatic circuit closing device to minimize wiring errors and leverage the CT provisioning capability when CT-based metering is required. Verify enclosure placement complies with Type 3R outdoor mounting guidelines.
Yes. The meter socket is designed to meet CSA 27716 standards, supporting regulatory compliance for North American metering installations. Its Weatherproof Type 3R enclosure further enhances suitability for outdoor use, providing robust protection against weather while simplifying documentation and audit processes.
This meter socket is ideal for overhead or underground metering in commercial and light industrial settings, especially where CT-based metering is planned or required. The 400 A rating and 120/240 V single-phase specification suit most general service entrances, while the 5 jaw configuration supports reliable connection in compact spaces.
Key specs include 400 A current rating, 120/240 V voltage rating, single-phase operation, 5 jaw meter socket configuration, and a Weatherproof Type 3R enclosure. It also offers CT provisioning for metering applications and CSA 27716 compliance, with compatibility for overhead and underground installations in Canada and the US.
The automatic circuit closing device reduces manual re-closure steps after faults, while CT provisioning supports accurate monitoring without rework. The Weatherproof Type 3R enclosure minimizes weather-related degradation, lowering maintenance frequency. CSA 27716 compliance and a robust design translate to fewer field failures and clearer regulatory alignment for procurement and servicing teams.