ABB EC1884 Control Door Kit for Enclosures - CE IS2
Part Number: EC1884
Quick Summary
EC1884 is an ABB control door kit for server enclosures in data centers and industrial cabinets. Engineers often struggle with secure, unobstructed access while maintaining proper airflow and a compact footprint. The design supports CE conformity, RoHS and REACH compliance, and ETIM classification to simplify sourcing and interoperability. With an orange peel finish in RAL 7035 and a 180° opening, service and maintenance become faster and safer. This combination of durability, standards compliance, and install-ready packaging delivers tangible time and cost savings for automation projects. Whether upgrading legacy cabinets or deploying in new builds, EC1884 aligns with IS2 enclosures and supports scalable enclosure strategy.
Product Information
Extended Description
EC1884 ABB: Aerated door for server enclosure 180°op.1800x800
Accessory Type
3. Other doors
Configuration Type
3. Door
Mounting Type
Kit
Product Type
5B5B20B230
Door Type
Single
Surface Finishing
Orange Peel, RAL 7035
Door Surface Finishing
Opaque
Material
Pickled steel sheet
Options Provided
5. Aerated door with 180° door opening
Remarks
ETIM
RAL Number
RAL 7035 - Light Grey
RoHS Information
RoHS information
RoHS Date
20250108
REACH Declaration
REACH declaration
REACH Information
False - does not contain substances > 0.1 mass percentage
REACH Date
20250108
WEEE Category
Product Not in WEEE Scope
Environmental Information
IS2 Enclosures Technical Catalogue 2024
Product Net Width
794 mm
Product Net Height
1796 mm
Product Net Depth / Length
46 mm
Product Net Weight
18.370 kg
Reference Depth/Length
400 mm | 500 mm | 600 mm | 800 mm | 1000 mm
Reference Height
1800 mm
Reference Width
800 mm
Package Level 1 Units
1 piece
Package Level 1 Gross Weight
19.370 kg
Declaration of Conformity - CE
Declaration of Conformity IS2
Instructions and Manuals
1STM604121R0006
Data Sheet, Technical Information
IS2 Enclosures Technical Catalogue 2024
ETIM 8
EC000747 - Door/operating panel (enclosure/cabinet)
ETIM 9
EC000747 - Door/operating panel (enclosure/cabinet)
eClass
V11.1 : 27182204
Object Classification Code
U
Standards
See code for structure
Feature: Aerated door with 180° opening provides full access and improved cooling efficiency. Business Impact: Faster maintenance cycles, reduced downtime, and better airflow management in densely packed cabinets. Application: Data centers and industrial control rooms where hot-swappable components are routine. Long-tail keywords integrated: aerated door for server enclosure, 180° door opening, enclosure access efficiency.Feature: Material and finish use pickled steel sheet with Orange Peel surface in RAL 7035. Business Impact: Enhanced corrosion resistance, consistent color coding, and long-term appearance in harsh environments. Application: Outdoor or semi-enclosed industrial enclosures requiring durable aesthetics and compliance. Long-tail keywords: RAL 7035 light grey, door surface finishing, enclosure durability.Feature: Mounting Type Kit with reference depth options (400–1000 mm) and fixed dimensions (800 mm width, 1800 mm height, 46 mm depth). Business Impact: Simplified installation, compatible with multiple enclosure depths, and predictable procurement. Application: Retrofit projects and new builds requiring flexible depth compatibility. Long-tail keywords: kit mounting, reference depth options, enclosure retrofit.Feature: Compliance and standards coverage including RoHS, REACH, CE declarations, and ETIM EC000747 classification. Business Impact: Regulatory risk reduction, easier supplier qualification, and smoother purchasing workflows. Application: Projects in regulated sectors like data centers and manufacturing automation. Long-tail keywords: CE Declaration of Conformity, ETIM classification EC000747, RoHS information.Feature: Dimensions and weight (Net width 794 mm, Net height 1796 mm, Net depth 46 mm, Net weight 18.370 kg; packaged 19.370 kg). Business Impact: Precise fitment and handling, reduced freight risk, and predictable space planning. Application: Enclosures planning, rack mounting, and maintenance planning. Long-tail keywords: enclosure door dimensions, 18.37 kg weight, 794 mm width.
Get a Quick Quote for a ABB EC1884
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB EC1884?
Enquire Now
FAQs
The EC1884 kit is designed for mounting as a single door on ABB enclosure systems. Start by aligning the door with the enclosure frame, secure the mounting kit to the designated points, and ensure the 180° door opening clearance is unobstructed. The kit supports standard depths from 400 to 1000 mm, simplifying retrofit projects and new builds. Use the IS2 Enclosures Catalogue 2024 as a reference for compatible enclosure models and installation guidance.
EC1884 carries CE conformity, RoHS information with a 20250108 RoHS date, and REACH information indicating no substances above 0.1 mass percentage. It is classified under ETIM EC000747 for door/operating panels. These certifications simplify regulatory compliance, ensure safe material usage, and streamline procurement across automotive, data center, and industrial automation projects.
Yes. The EC1884 is specifically described as an aerated door with 180° door opening, enabling full access to server cabinets and enclosure interiors. This capability reduces maintenance time, improves component reach, and supports higher-density layouts common in modern data centers and industrial facilities.
Key dimensions include a net width of 794 mm, net height of 1796 mm, and net depth of 46 mm, with a net weight of 18.370 kg. Package weight is 19.370 kg. The reference height is 1800 mm and reference width is 800 mm, with depth options extending 400–1000 mm for compatibility with various enclosure depths.
The door is made from pickled steel sheet with an orange peel surface finished in RAL 7035 (light grey) and an opaque door surface. This combination provides corrosion resistance, consistent appearance, and suitability for industrial environments, while meeting RoHS and REACH requirements to support regulatory compliance.