ABB 1SDA054502R1 is a Moulded Case Circuit Breaker designed for reliable overcurrent protection in industrial control panels. Engineers often face downtime due to short-circuit events and wiring complexity; this device helps mitigate those risks with precise tripping and robust interrupting capabilities. It is CE-conformant, IEC-compliant, and RoHS-ready, with additional CMRT and TSCA declarations supporting global deployment and compliance. With front terminals for copper cables and a four-pole, 160 A rating, it integrates smoothly into modern automation architectures while simplifying procurement and maintenance for panel builders and system integrators.
Product Information
Extended Description
EE2308K ABB: Recessed counterdoors 2200x800mm (HxW)
Suitable For
IS2 Enclosures for Automation
Suitable for Product Class
Control and Automation Board
Accessory Type
3. Other doors
Mounting Type
Kit | Pre assembled
Product Type
5B5B30B360
Door Type
Inner Door
Door Surface Finishing
Opaque
Material
Pickled steel sheet
Options Provided
3. Recessed inner doors
Remarks
ETIM
RAL Number
RAL 7035 - Light Grey
RoHS Information
RoHS information
RoHS Date
20250108
REACH Declaration
REACH declaration
REACH Information
False - does not contain substances > 0.1 mass percentage
REACH Date
20250108
WEEE Category
Product Not in WEEE Scope
Environmental Information
IS2 Enclosures Technical Catalogue 2024
Product Net Width
800 mm
Product Net Height
2100 mm
Product Net Depth / Length
800 mm
Product Net Weight
26.450 kg
Reference Depth/Length
300 mm | 400 mm | 500 mm | 600 mm | 800 mm | 1000 mm
Reference Height
2200 mm
Reference Width
800 mm
Package Level 1 Units
1 piece
Package Level 1 Gross Weight
26.990 kg
Declaration of Conformity - CE
Declaration of Conformity IS2
Instructions and Manuals
1STM604121R0006
Data Sheet, Technical Information
IS2 Enclosures Technical Catalogue 2024
ETIM 8
EC000747 - Door/operating panel (enclosure/cabinet)
ETIM 9
EC000747 - Door/operating panel (enclosure/cabinet)
eClass
V11.1 : 27182204
Object Classification Code
U
Standards
See code for structure
Four-pole fixed design with front terminals for copper cables enables rapid, tidy panel wiring, reducing installation time and the potential for misconnections. This directly lowers labor costs and shortens commissioning windows, which is critical in high-mix, low-volume production environments. The unit’s 160 A rated current and 1150 V insulation/operational voltage provide robust fault protection for motors and transformers, with Ics up to 12 kA at 1000 V AC and Icu up to 40 kA, supporting safe operation in high fault energy scenarios. TMA/TM release options in a Tmax T4 family breaker deliver selective coordination and faster, predictable trips, improving machine uptime and minimizing collateral damage during faults. Durability figures—8000 electrical cycles and 20000 mechanical cycles—translate to longer service life in continuous-duty panels, with manageable energy loss of 7.4 W per pole aiding thermal stability. Compliance and documentation, including CE, IEC, RoHS, CMRT, and TSCA declarations, simplify audits and sustainability reporting while ensuring global operability. Compatible with fixed-front-terminal designs, this MCCB is suitable for distributions boards and control panels in automation lines seeking reliability, traceability, and efficient maintenance.
Get a Quick Quote for a ABB EE2308K
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB EE2308K?
Enquire Now
FAQs
This MCCB uses fixed front-terminal connections designed for copper cables, simplifying wiring runs and improving wiring integrity in panel builds. The 4P configuration supports straightforward rail mounting and aligns with Tmax T4 architectures, enabling quick integration into standard control panels and distribution boards.
Key specs include a rated current of 160 A, rated insulation voltage of 1150 V, rated operating voltage of 1150 V AC / 1000 V DC, and short-circuit breaking capacities of up to 12 kA (1000 V AC) and 40 kA (1000 V DC). It supports 8000 electrical cycles and 20000 mechanical cycles, with a power loss of 7.4 W per pole.
Yes. The device is designed as a Tmax T4 four-pole Moulded Case Circuit Breaker with TMA release, suitable for motor and transformer protection in industrial automation. It supports 4P protection, front-cable terminations, and is compatible with T4 extension in distribution panels, ensuring reliable motor startup and shutdown coordination.
The product ships with CE conformity and IEC standards alignment, RoHS declarations, CMRT for conflict minerals reporting, and TSCA declarations. These certifications support regulatory compliance, sustainability reporting, and global manufacturing or installation across regions.
Product net dimensions are 140 mm wide, 205 mm high, and 103.5 mm deep, with a net weight of 3.05 kg. Packaging Level 1 consists of 1 unit per box with outer dimensions of 248 mm x 240 mm x 285 mm and a gross weight of ~3.5 kg. The standard EAN is 8015644556044.