ABB GJL1201317R0004 Auxiliary Contact - IEC/UL Certified

Part Number: GJL1201317R0004
Manufacturer
ABB
Part number
GJL1201317R0004

Quick Summary

Auxiliary Contact GJL1201317R0004 provides 1NO/1NC side-mounted signaling for control circuits in motor starters. Engineers often battle space constraints and wiring clutter when expanding signaling points, so a compact, reliable auxiliary contact is essential. This device meets key standards such as IEC/EN 60947-1, UL 60947-1 and CE markings, plus RoHS and IP20 protection to ensure safe integration in industrial panels. By delivering a robust signaling option that fits mini contactors without sacrificing performance, it reduces panel footprint and installation time while elevating control reliability. For procurement teams, this accessory streamlines spare parts and simplifies maintenance in B6-30-01, BC6-30-01 and similar configurations.

Product Information

Extended Description

GJL1201317R0004 ABB: CA6-11N is an auxiliary contact for side with 2 auxiliary contact and screw terminals.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
2CDC102047M6801
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing - Mini Contactor Accessories CA6
Product Net Width
20.3 mm
Product Net Depth / Length
46.5 mm
Product Net Height
48.5 mm
Product Net Weight
0.03 kg
Number of Main Contacts NO
0
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
2P
Standards
IEC/EN 60947-1 | IEC/EN 60947-4-1 | IEC/EN 60947-5-1 | UL 60947-1 | UL 60947-4-1 | IEC 60335-2-40 A2L
Rated Operational Voltage
Auxiliary Circuit 690 V AC | Auxiliary Circuit 250 V DC
Rated Frequency (f)
Auxiliary Circuit 50 Hz | Auxiliary Circuit 60 Hz | Auxiliary Circuit DC
Conventional Free-air Thermal Current (Ith)
Auxiliary Circuit 6 A
Rated Operational Current AC-15 (Ie)
(24 V) 4 A | (240 V) 4 A | (500 V) 2 A | (380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 1.5 A | (110 V) 0.4 A | (220 / 240 V) 0.04 A
Short-Circuit Protective Devices
gG Type Fuses 10 A
Rated Insulation Voltage (Ui)
690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-15) 600 cycles per hour | (DC-13) 600 cycles per hour
Minimum Switching Capacity
17 V | 5 mA
Power Loss
at Rated Operating Conditions per Pole 0.27 W
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm² | Flexible 1/2x 1 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm
Degree of Protection
IP20
Tightening Torque
Auxiliary Circuit 0.8 ... 1.1 N·m
Terminal Type
Screw Terminals
Suitable For
B6-30-01 | BC6-30-01 | B7-30-01 | BC7-30-01
Suitable for Product Class
Mini Contactors
Product Name
Auxiliary Contact
Maximum Operating Voltage UL/CSA
600 V AC
General Use Rating UL/CSA
(600 V AC) 5 A
Connecting Capacity Auxiliary Circuit UL/CSA
Stranded 1/2x 22-10 AWG
Contact Rating UL/CSA
A600
Tightening Torque UL/CSA
Auxiliary Circuit 7 in·lb
Ambient Air Temperature
Operation -25 ... +55 °C | Storage -40 ... +80 °C
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Resistance to Vibrations
5g 5 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – IEC
A2L Certificate - B6-, B7-, K6- series, CA6, CAF6 - Mini Contactor
CB Certificate
CB Certificate - K6, KC6, CA6 - Mini Contactor
CQC Certificate
CQC Certificate, Contactor relays, K6,KC6,CA6,CAF6, Made in Germany
cULus Certificate
cUL_E48139
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor relays, K6,KC6,CA6,CAF6, Made in Germany
Declaration of Conformity - CE
EU Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
Declaration of Conformity - UKCA
UK Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
EAC Certificate
EAC Certificate - CA6, CAF6, EH04 - Contactors
RMRS Certificate
RMRS Certificate - K6, KC6, CA6, CAF6 - Mini Contactor
UL Certificate
UL_E48139
Package Level 1 Units
box 10 piece
Package Level 1 Width
112 mm
Package Level 1 Depth / Length
142 mm
Package Level 1 Height
62 mm
Package Level 1 Gross Weight
0.365 kg
Package Level 1 EAN
4013614412110
Object Classification Code
K
ETIM 7
EC000041 - Auxiliary contact block
ETIM 8
EC000041 - Auxiliary contact block
ETIM 9
EC000041 - Auxiliary contact block
eClass
V11.0 : 27371302
UNSPSC
39121522
IDEA Granular Category Code (IGCC)
4743 >> Auxiliary contact block
E-Number (Finland)
3709104
E-Number (Norway)
4184084
Feature → Business Impact → Application. Side-mounted 2P auxiliary contact with 1NO/1NC contacts provides straightforward signaling for main contactors, reducing wiring complexity and panel space. This translates to faster assembly, lower labor costs, and easier troubleshooting in motor control circuits. Application with ABB CA6 mini contactors enables compact control panels in conveyors, pumps, and machine tools, improving reliability and maintainability. Feature → Business Impact → Application. Rated operational voltage for auxiliary circuits up to 690 V AC and 250 V DC supports diverse control logic, enabling universal compatibility across 50/60 Hz systems and DC control schemes. This ensures compliant integration in mixed-technology lines, lowering the risk of mis-match and rework. Feature → Business Impact → Application. Screw terminals with defined torque (0.8–1.1 N·m) and wire-capacity options (flexible ferrule 0.5–2.5 mm², rigid 0.5–4 mm²) deliver secure, vibration-resistant connections, reducing loose-contact failures and service interruptions. Application includes panel-mounted motor starters, safety interlocks, and signaling circuits in harsh environments. Feature → Business Impact → Application. Dimensions 20.3 mm width, 46.5 mm depth, 48.5 mm height and weight 0.03 kg enable a truly space-saving solution for compact control enclosures, while maintaining ease of handling and installation. Application includes retrofit in existing CA6-based setups to minimize downtime. Feature → Business Impact → Application. Certifications and compliance (CE, UL/CSA, IEC standards) provide confidence to procurement and QA teams, supporting audits and regulatory alignment across global facilities. Application across industrial segments seeking RoHS-compliant, recyclable, and serviceable signaling accessories.

Get a Quick Quote for a ABB GJL1201317R0004

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB GJL1201317R0004? Enquire Now

FAQs

Yes. The CA6-11N auxiliary contact is designed for side mounting on CA6 mini contactors and similar compact control components, featuring screw terminals and a 2P configuration (1NO/1NC). It fits standard panel environments and maintains a compact footprint suitable for space-constrained cabinets.
Rated Operational Current AC-15: (24 V) 4 A, (240 V) 4 A, (380/400 V) 3 A, (500 V) 2 A. Rated Operational Current DC-13: (24 V) 1.5 A, (110 V) 0.4 A, (220/240 V) 0.04 A. These values support signaling functions across a range of motor-control and automation circuits while maintaining safe operating margins.
Yes. The CA6 family, including CA6-11N auxiliaries, is specified for compatibility with B6-30-01, BC6-30-01, B7-30-01, and BC7-30-01 variants, enabling streamlined upgrades and consistent signaling across ABB mini contactor lines.
It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and RoHS/REACH requirements, with CE and UKCA markings. Additional declarations include A2L/UL certificates and WEEE considerations for B2B environments, supporting regulatory and supplier-audits.
The unit features IP20 protection and robust screw-terminal connections with 0.8–1.1 N·m torque, reducing vibration-related loosening. It also delivers low power loss per pole (0.27 W) and compact dimensions, contributing to lower energy use, easier replacements, and reduced downtime in ongoing production and maintenance routines.