ABB GJL1201319R0002 Auxiliary Contact - IP20
Part Number: GJL1201319R0002
Quick Summary
ABB GJL1201319R0002 Auxiliary Contact provides side-mounted 1NO/1NC signaling for ABB mini contactors in control panels. Engineers often wrestle with space constraints, unreliable signaling, and wiring reliability during retrofit projects. The part complies with IEC/EN 60947-1, IEC/EN 60947-4-1, and UL/ULc safety listings with CE marking, supporting global deployment. As a compact, soldering-pin accessory, it reduces panel depth while delivering robust signaling and straightforward maintenance. This solution aligns with ABB mini contactor portfolios, offering quick replacement and predictable lifecycle costs. In practice, it enables consistent control logic, lowers commissioning risk, and supports scalable automation architectures.
Product Information
Extended Description
GJL1201319R0002 ABB: CA6-11E-P is an auxiliary contact for side with 2 auxiliary contact and soldering pins.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
2CDC102047M6801
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing - Mini Contactor Accessories CA6 (-P)
Product Net Width
20.3 mm
Product Net Depth / Length
51.5 mm
Product Net Height
48.5 mm
Product Net Weight
0.025 kg
Number of Main Contacts NO
0
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
2P
Standards
IEC/EN 60947-1 | IEC/EN 60947-4-1 | IEC/EN 60947-5-1 | UL 60947-1 | UL 60947-4-1 | IEC 60335-2-40 A2L
Rated Operational Voltage
Auxiliary Circuit 690 V AC | Auxiliary Circuit 250 V DC
Rated Frequency (f)
Auxiliary Circuit 50 Hz | Auxiliary Circuit 60 Hz | Auxiliary Circuit DC
Conventional Free-air Thermal Current (Ith)
Auxiliary Circuit 6 A
Rated Operational Current AC-15 (Ie)
(24 V) 4 A | (240 V) 4 A | (500 V) 2 A | (380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 1.5 A | (110 V) 0.4 A | (220 / 240 V) 0.04 A
Short-Circuit Protective Devices
gG Type Fuses 10 A
Rated Insulation Voltage (Ui)
690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-15) 600 cycles per hour | (DC-13) 600 cycles per hour
Minimum Switching Capacity
17 V | 5 mA
Power Loss
at Rated Operating Conditions per Pole 0.27 W
Degree of Protection
IP20
Terminal Type
Soldering Pins
Suitable For
B6-40-00-P | BC6-40-00-P | B7-40-00-P | BC7-40-00-P
Suitable for Product Class
Mini Contactors
Product Name
Auxiliary Contact
Maximum Operating Voltage UL/CSA
600 V AC
General Use Rating UL/CSA
(600 V AC) 5 A
Contact Rating UL/CSA
A600
Ambient Air Temperature
Operation -25 ... +55 °C | Storage -40 ... +80 °C
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Resistance to Vibrations
5g 5 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – IEC
A2L Certificate - B6-, B7-, K6- series, CA6, CAF6 - Mini Contactor
CB Certificate
CB Certificate - K6, KC6, CA6 - Mini Contactor
CQC Certificate
CQC Certificate, Contactor relays, K6,KC6,CA6,CAF6, Made in Germany
cURus Certificate
cUL_E48139
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor relays, K6,KC6,CA6,CAF6, Made in Germany
Declaration of Conformity - CE
EU Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
Declaration of Conformity - UKCA
UK Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
EAC Certificate
EAC Certificate - CA6, CAF6, EH04 - Contactors
RMRS Certificate
RMRS Certificate - K6, KC6, CA6, CAF6 - Mini Contactor
UL Certificate
UL Certificate of Compliance - K6, KC6, CA6 (Pin/Faston), LB6, LB6CA - Mini Contactor
UR Certificate
1SAA938000-1801
Package Level 1 Units
box 10 piece
Package Level 1 Width
112 mm
Package Level 1 Depth / Length
142 mm
Package Level 1 Height
62 mm
Package Level 1 Gross Weight
0.315 kg
Package Level 1 EAN
4013614412196
Object Classification Code
K
ETIM 7
EC000041 - Auxiliary contact block
ETIM 8
EC000041 - Auxiliary contact block
ETIM 9
EC000041 - Auxiliary contact block
eClass
V11.0 : 27371302
UNSPSC
39121522
IDEA Granular Category Code (IGCC)
4743 >> Auxiliary contact block
Side-mounted 2P auxiliary contact with 1 NO / 1 NC provides additional signaling without expanding the footprint of the mini contactor. This compact integration reduces wiring complexity and panel congestion, enabling faster commissioning and easier field replacements. Use this accessory on compatible ABB mini contactors to extend signaling circuits in machine controls and safety interlocks. Soldering-pin terminals deliver robust, vibration-resistant connections, simplifying panel assembly and reducing loose-wiring risk in harsh manufacturing environments. Compliance with IEC/EN 60947-1, IEC/EN 60947-4-1, and UL/CE listings minimizes regulatory hurdles and validates safety for global deployment. Rated for auxiliary circuits up to 690 V AC and 250 V DC, it supports both control and signaling applications in motor control centers. With an IP20 protection level and compact dimensions, the accessory fits tight control panels while maintaining easy field replacement and serviceability. Its compatibility with B6-40-00-P, BC6-40-00-P, B7-40-00-P, and BC7-40-00-P families makes it a cost-efficient addition to the ABB mini contactor ecosystem.
Get a Quick Quote for a ABB GJL1201319R0002
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB GJL1201319R0002?
Enquire Now
FAQs
Install the CA6-11E-P on the side of a compatible ABB mini contactor, align the soldering-pin terminals with the contactor base, and solder each pin to the control wiring. Verify 1NO/1NC configuration and ensure IP20 enclosure protection is maintained. Double-check clearance to prevent short circuits and test the signaling circuit under low current first.
The auxiliary contact supports auxiliary circuits up to 690 V AC and 250 V DC, with rated currents suitable for signaling applications (Ith 6 A in auxiliary circuits). In AC-15, it functions within the standard control circuit range, while DC-13 ratings are modest, suitable for signaling and interlocks rather than main power switching.
Yes. The CA6-11E-P is listed against IEC/EN 60947-1 and 60947-4-1, with UL/ULc listings and CE marking. This ensures broad international acceptance, smoother regulatory approvals for machine builds, and safer integration into global control panels.
Its side-mounted, 2P design with soldering-pin terminals delivers a compact footprint (2 poles, 1 NO/1 NC) and straightforward wiring. The IP20 rating protects the small internal contacts in indoor enclosures, enabling quick replacement without redesigning the panel layout.
The combination reduces wiring complexity, speeds commissioning, and lowers maintenance time through reliable soldered connections. With broad certifications and compatibility across ABB mini contactor families, it minimizes spare-part variety and supports scalable automation, delivering measurable lifecycle cost savings and improved uptime.