ABB GJL1201330R0003 Auxiliary Contact - Front Mount, IP20
Part Number: GJL1201330R0003
Quick Summary
Auxiliary Contact for front-mounted signaling supports ABB mini contactor systems in compact electrical control panels. In tight enclosures, wiring clutter and unreliable signaling can delay startup and complicate troubleshooting. This accessory complies with IEC/EN 60947-1, IEC/EN 60947-4-1, and UL 60947-1/60947-4-1, with CE and UKCA declarations, plus IP20 protection for indoor panel use. As a front-mounted signaling accessory for B6-30-10, BC6-30-10, and related mini contactors, it simplifies wiring and feedback paths while maintaining safe, code-compliant operation. The result is faster field installation, more reliable interlocks, and a lower total-cost-of-ownership for control panel assemblies.
Product Information
Extended Description
GJL1201330R0003 ABB: The CAF6-11M is an auxiliary contact for front mounting with 2 auxiliary contact and screw terminals.
Country of Origin
Switzerland (CH)
Lead Time
28 day
Made To Order
No
Product Sales Status
Inactive
Quote Only
No
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Operating instruction - CAF6 Auxiliary contact for front mounting
Instructions and Manuals (Part 2)
Operating instruction - CAF6 Auxiliary contact for front mounting
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing - Mini Contactor Accessories CAF6
Product Net Width
47.5 mm
Product Net Depth / Length
26.5 mm
Product Net Height
29 mm
Product Net Weight
0.02 kg
Number of Main Contacts NO
0
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
2P
Standards
IEC/EN 60947-1 | IEC/EN 60947-4-1 | IEC/EN 60947-5-1 | UL 60947-1 | UL 60947-4-1 | IEC 60335-2-40 A2L
Rated Operational Voltage
Auxiliary Circuit 690 V AC | Auxiliary Circuit 250 V DC
Rated Frequency (f)
Auxiliary Circuit 50 Hz | Auxiliary Circuit 60 Hz | Auxiliary Circuit DC
Conventional Free-air Thermal Current (Ith)
Auxiliary Circuit 6 A
Rated Operational Current AC-15 (Ie)
(24 V) 4 A | (240 V) 4 A | (500 V) 2 A | (380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 1.5 A | (110 V) 0.4 A | (220 / 240 V) 0.04 A
Short-Circuit Protective Devices
gG Type Fuses 10 A
Rated Insulation Voltage (Ui)
690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-15) 600 cycles per hour | (DC-13) 600 cycles per hour
Minimum Switching Capacity
17 V | 5 mA
Power Loss
at Rated Operating Conditions per Pole 0.27 W
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm² | Flexible 1/2x 1 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm
Degree of Protection
IP20
Tightening Torque
Auxiliary Circuit 0.8 ... 1.1 N·m
Terminal Type
Screw Terminals
Suitable For
B6-30-10 | BC6-30-10 | B7-30-10 | BC7-30-10 | VB6-30-10 | VBC6-30-10 | VB7-30-10 | VBC7-30-10 | VB6A-30-10 | VBC6A-30-10 | VB7A-30-10 | VBC7A-30-10
Suitable for Product Class
Mini Contactors
Product Name
Auxiliary Contact
Maximum Operating Voltage UL/CSA
600 V AC
General Use Rating UL/CSA
(600 V AC) 5 A
Connecting Capacity Auxiliary Circuit UL/CSA
Stranded 1/2x 22-10 AWG
Contact Rating UL/CSA
A600
Tightening Torque UL/CSA
Auxiliary Circuit 7 in·lb
Ambient Air Temperature
Operation -25 ... +55 °C | Storage -40 ... +80 °C
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Resistance to Vibrations
5g 5 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – IEC
A2L Certificate - B6-, B7-, K6- series, CA6, CAF6 - Mini Contactor
CQC Certificate
CQC Certificate, Contactor relays, K6,KC6,CA6,CAF6, Made in Germany
cULus Certificate
cUL_E48139
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor relays, K6,KC6,CA6,CAF6, Made in Germany
Declaration of Conformity - CE
EU Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
Declaration of Conformity - UKCA
UK Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
EAC Certificate
EAC Certificate - CA6, CAF6, EH04 - Contactors
RMRS Certificate
RMRS Certificate - K6, KC6, CA6, CAF6 - Mini Contactor
UL Certificate
UL_E48139
Package Level 1 Units
box 10 piece
Package Level 1 Width
115 mm
Package Level 1 Depth / Length
280 mm
Package Level 1 Height
54 mm
Package Level 1 Gross Weight
0.24 kg
Package Level 1 EAN
4013614412240
Object Classification Code
K
ETIM 7
EC000041 - Auxiliary contact block
ETIM 8
EC000041 - Auxiliary contact block
ETIM 9
EC000041 - Auxiliary contact block
eClass
V11.0 : 27371302
UNSPSC
39121522
IDEA Granular Category Code (IGCC)
4743 >> Auxiliary contact block
E-Number (Finland)
3709108
E-Number (Norway)
4184088
Feature → Business Impact → Application: Front-mount design simplifies installation and reduces enclosure depth requirements, improving panel layout and maintenance access in tight control rooms; enables quick retrofits on existing ABB mini contactor configurations, reducing downtime during upgrades. Feature → Business Impact → Application: Dual NO/NC auxiliary contacts (1 each) provide immediate signaling and interlock feedback, enabling precise motor protection signaling and safer start sequences in automated lines across packaging, material handling, and process automation. Feature → Business Impact → Application: Screw-terminal connections with defined wire ranges (1/2x 1 ... 4 mm²) deliver reliable field wiring and straightforward terminations, cutting commissioning time and minimizing connection failures in harsh factory environments. Feature → Business Impact → Application: Conforms to multiple standards (IEC/EN, UL, CE, UKCA), ensuring regulatory compliance for global installations and smoother procurement across international sites in manufacturing and utilities. Feature → Business Impact → Application: Compact 2P footprint with IP20 protection delivers dependable operation in vertical or horizontal layouts, enabling compact motor control centers and space-saving panel designs. Feature → Business Impact → Application: Widely compatible with Mini Contactor families (B6, B7, VB6, VB7, VBC6, VBC7, etc.), ensuring seamless integration into existing ABB control architectures and minimizing spare parts inventory.
Get a Quick Quote for a ABB GJL1201330R0003
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB GJL1201330R0003?
Enquire Now
FAQs
Install the CAF6 auxiliary contact by aligning the device with the mating mini contactor, securing it with the front-m mounting screws, and wiring the auxiliary circuit through the screw terminals. Use 1/2x 22-10 AWG or 1/2x 1 ... 2.5 mm² wires per the specification, and tighten to 0.8 to 1.1 N·m. Verify continuity before energizing the main circuit.
For AC-15 operation, Ie is up to 4 A at 24 V, 4 A at 240 V, 3 A at 380/400 V, and 2 A at 500 V. For DC-13, Ie is 1.5 A at 24 V, 0.4 A at 110 V, and 0.04 A at 220/240 V. These ratings enable signaling contacts to handle legitimate control circuits and interlocks within motor control schemes.
Yes. CAF6 is designed as a front-mounted auxiliary contact compatible with B6-30-10, BC6-30-10, B7-30-10, BC7-30-10, VB6-30-10, VBC6-30-10, VB7-30-10, and VBC7-30-10 families, among others. The 2P, 1NO/1NC configuration supports signaling and interlocking across these standard ABB mini contactor lines.
The CAF6 auxiliary contact carries CE and UKCA declarations of conformity, UL/CSA listings, EAC, RMRS, and A2L declarations, plus RoHS compliance and WEEE categorization. These certifications help ensure regulatory compliance for global deployments and simplify cross-border procurement and installation.
Using CAF6 reduces wiring complexity and panel footprint, cuts installation time, and improves signaling reliability, which lowers downtime and maintenance costs. The screw-terminal design provides durable connections, while standard-compliant components minimize replacement cycles and support long-term total cost of ownership reductions.