ABB GJL1213009R1106 Mini Contactor - UL/CSA Certified

Part Number: GJL1213009R1106
Manufacturer
ABB
Part number
GJL1213009R1106

Quick Summary

Mini Contactor ABB GJL1213009R1106 provides compact, reliable control for single- and three-phase loads in industrial automation. In space-constrained panels, customers face mounting heat, cabling clutter, and frequent coil failures that disrupt uptime. This device complies with UL/CSA and CE alongside IEC 60947-1/4-1 standards, ensuring safety and interoperability across global installations. Its 3P, 3 NO with 1 auxiliary NO configuration supports flexible wiring for control circuits, while the 48 V DC coil keeps heat low in powered enclosures. The combination of small form factor and robust ratings delivers measurable business value through reduced panel size, simplified installation, and improved maintenance cycles.

Product Information

Extended Description

GJL1213009R1106 ABB: The BC6-30-10-P mini contactor is a compact 3 pole contactor with 1 auxiliary contact and soldering pins. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 4 kW (AC-3) and 12 A (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil and a switch position indication.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
2CDC102047M6801
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing - B6 / BC6 / B7 / BC7 / K6 / KC6 (-P)
Product Net Width
47.5 mm
Product Net Depth / Length
47.7 mm
Product Net Height
45.2 mm
Product Net Weight
0.17 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1 | IEC/EN 60947-4-1 | IEC/EN 60947-5-1 | UL 60947-1 | UL 60947-4-1 | IEC 60335-2-40 A2L
Rated Operational Voltage
Auxiliary Circuit 690 V AC | Auxiliary Circuit 250 V DC | Main Circuit 690 V AC | Main Circuit 220 V DC
Rated Frequency (f)
Control Circuit DC | Main Circuit 60 Hz | Main Circuit 50 Hz | Main Circuit DC
Conventional Free-air Thermal Current (Ith)
Main Circuit 12 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 40 °C 12 A | (220 / 240 V) 55 °C 12 A | (380 / 440 V) 40 °C 12 A | (380 / 440 V) 55 °C 12 A | (690 V) 40 °C 6 A | (690 V) 55 °C 6 A
Rated Operational Current AC-3 (Ie)
(230 V) 55°C 9 A | (400 V) 55 °C 9 A | (500 V) 55 °C 6.5 A | (690 V) NO 55°C 3.5 A
Rated Operational Current AC-15 (Ie)
(24 V) 4 A | (120 V) 4 A | (500 V) 2 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 2.5 A | (110 V) 0.7 A | (220 / 240 V) 0.4 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 2.2 kW | (400 V) Three Phase 4 kW | (500 V) Three Phase 4 kW | (690 V) Three Phase, NO 3 kW
Rated Breaking Capacity AC-3
8 x Ie / AC-3
Rated Making Capacity AC-3
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
Rated Insulation Voltage (Ui)
690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV | Main Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-15) 600 cycles per hour | (AC-3) 600 cycles per hour | (DC-1) 600 cycles per hour | (DC-13) 600 cycles per hour | (DC-3) 600 cycles per hour
Mechanical Durability
Nr. Operations 10000000 cycle
Minimum Switching Capacity
Auxiliary Circuit 17 V | Auxiliary Circuit 5 mA
Coil Operating Limits
(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)
48 V DC
Coil Consumption
Average Holding Value DC 3.5 W | Average Pull-in Value DC 3.5 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 1 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Degree of Protection
Auxiliary Circuit Terminals IP20 | Control Circuit Terminals IP20 | Main Circuit Terminals IP20
Terminal Type
Soldering Pins
Mini Contactor Type
Mini Contactor
Product Name
Mini Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
General Use Rating UL/CSA
(300 V AC) 8 A
Horsepower Rating UL/CSA
(115 V AC) Single Phase 0.25 Hp | (200 V AC) Three Phase 1 Hp | (220 ... 240 V AC) Three Phase 2 Hp | (230 V AC) Single Phase 0.5 Hp | (440 ... 480 V AC) Three Phase 3 Hp | (550 ... 600 V AC) Three Phase 1 Hp
Contact Rating UL/CSA
A600
Full Load Amps Motor Use
(115 V AC) Single Phase 5.8 A | (200 V AC) Three Phase 4.8 A | (220 ... 240 V AC) Three Phase 6.8 A | (230 V AC) Single Phase 4.9 A | (440 ... 480 V AC) Three Phase 4.8 A | (550 ... 600 V AC) Three Phase 1.7 A
Ambient Air Temperature
Operation -25 ... +55 °C | Storage -40 ... +80 °C
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Resistance to Vibrations
5g 5 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End Of Life Instruction B(C)6-P, B(C)7-P, K(C)6-P, VB(C)6-P, VB(C)7-P
Environmental Product Declaration - EPD
Environmental Product Declaration PEP B(C)6, B(C)7 (EN)
A2L Certificate – IEC
A2L Certificate - B6-, B7-, K6- series, CA6, CAF6 - Mini Contactor
BV Certificate
BV Certificate - ESB24, ESB40, ESB63, EH04, B6, B7, EH04 - Installation Contactor
CB Certificate
CB Certificate - B6, BC6, VB6, VBC6, B7, BC7, VB7, VBC7 - Mini Contactor
CQC Certificate
CQC Certificate, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
cURus Certificate
cUL_E191658
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
Declaration of Conformity - CE
EU Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
Declaration of Conformity - UKCA
UK Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
DNV GL Certificate
DNV Certificate - B6, B7 - Mini Contactor
EAC Certificate
EAC Certificate - B6, BC6, B6S, VB6,B7, BC7, B7D, B7S, VB7, TBC7, ESB24, EN24, ESB40, EN40, ESB63 - Contactors
KC Certificate
KC Certificate - B6, B7
LR Certificate
LR Certificate - B6, B7 - Mini Contactor
RMRS Certificate
RMRS Certificate - B6, BC6, B7, BC7, VB6, VBC6, VB7, VBC7 - Mini Contactor
Package Level 1 Units
box 10 piece
Package Level 1 Width
108 mm
Package Level 1 Depth / Length
247 mm
Package Level 1 Height
69 mm
Package Level 1 Gross Weight
1.775 kg
Package Level 1 EAN
4013614415159
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4763 >> Power contactor, DC switching
The 3-pole, 3NO/1 auxiliary NO configuration offers compact control of single- and three-phase loads, enabling panel space savings and easier wiring in industrial cabinets. This translates to tangible efficiency gains during installation and reduced enclosure footprint, particularly in buildings automation and manufacturing lines. The 48 V DC coil with a typical 3.5 W holding/pull-in and 1 W per pole power loss minimizes heat generation and energy consumption, improving overall panel reliability and reducing cooling requirements in control rooms or machine benches. Soldering pins provide robust, vibration-resistant connections that streamline field wiring and service replacements, supporting faster commissioning and easier diagnostics. With IP20 protection and TH35 DIN-rail mounting (TH35-15 or TH35-7.5), installation becomes straightforward in standard electrical enclosures, decreasing installation time and certified safety risks. Rated currents (AC-1 up to 12 A, AC-3 up to 9 A) enable reliable motor and load control up to several kilowatts, supporting scalable automation architectures. The unit’s mechanical durability of 10 million cycles and wide operating temperature (-25 to +55 °C) contribute to lower maintenance costs and longer service intervals, delivering predictable total cost of ownership for panel builders and end users. Compatibility with common standards and documentation aids compliance programs and OEM integration, reducing engineering lead times and accelerating time-to-production for automation projects.

Get a Quick Quote for a ABB GJL1213009R1106

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB GJL1213009R1106? Enquire Now

FAQs

This device mounts on standard TH35-15 or TH35-7.5 DIN rails, aligning with IEC 60715. It measures 47.5 x 47.7 x 45.2 mm and weighs 0.17 kg, simplifying enclosure layouts and reducing panel depth. Use the soldering pins for secure, vibration-resistant wiring and ensure IP20 protection is maintained in clean, indoor cabinets. Ambient temperature should remain between -25 and +55 °C.
Main contacts: 3 NO, 0 NC; Auxiliary: 1 NO. Rated AC-3 current is up to 9 A (at 230/400/500 V, 55 °C). AC-1 current is 12 A at 230/240 V (40/55 °C). The unit supports motor control up to 4 kW (AC-3) and control signaling loads with reliable switching, suitable for compact automation panels.
The GJL1213009R1106 complies with UL/CSA, CE, and IEC/EN 60947-1/60947-4-1. It also carries RoHS compliance and WEEE considerations for B2B deployment. These certifications support global deployment, interoperability with standard electrical installations, and regulatory conformity for electrical protection and control devices.
It delivers up to 10 million mechanical cycles, ensuring longevity in frequent switching applications. The coil operates within safe limits, and with 3.5 W coil consumption, heat generation remains low. The combination of Durability, IP20 protection, and robust soldered connections reduces maintenance frequency and extends service intervals in demanding environments.
The compact footprint and DIN-rail mounting save enclosure space and simplify wiring, reducing installation time. Low coil power minimizes heat, enabling smaller cooling requirements and energy savings. Long mechanical life lowers replacement costs while 3 NO/1 NO aux configurations support flexible control layouts, translating to faster commissioning and reduced total cost of ownership.