ABB BC7-30-01 Mini Contactor - UL/CSA Certified, 60 V DC
Part Number: GJL1313001R0013
Quick Summary
ABB BC7-30-01 Mini Contactor is a compact 3-pole switch designed to reliably control single- and three-phase loads in space-constrained panels. Engineers often struggle to fit robust motor control into tight enclosures without compromising performance or lifecycle costs. This device is CE-marked, UL/CSA listed, and CB certified, supporting global deployments with confidence. Its 60 V DC control coil, screw terminals, and DIN rail mounting simplify installation while delivering dependable switching for residential, commercial, and light industrial applications. The unit handles motor loads up to 5.5 kW (AC-3) and 20 A (AC-1), enabling compact, energy-efficient automation solutions. In short, it combines small form factor with proven safety and performance for modern automation projects.
Product Information
Extended Description
GJL1313001R0013 ABB: The BC7-30-01 mini contactor is a compact 3 pole contactor with 1 auxiliary contact and screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
2CDC102047M6801
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing - B6 / BC6 / B7 / BC7 / K6 / KC6
Product Net Width
52.5 mm
Product Net Depth / Length
46.7 mm
Product Net Height
57.5 mm
Product Net Weight
0.175 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1 | IEC/EN 60947-4-1 | IEC/EN 60947-5-1 | UL 60947-1 | UL 60947-4-1 | IEC 60335-2-40 A2L
Rated Operational Voltage
Auxiliary Circuit 690 V AC | Auxiliary Circuit 250 V DC | Main Circuit 690 V AC | Main Circuit 220 V DC
Rated Frequency (f)
Control Circuit DC | Main Circuit 50 Hz | Main Circuit 60 Hz | Main Circuit DC
Conventional Free-air Thermal Current (Ith)
Main Circuit 20 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 40 °C 20 A | (220 / 240 V) 55 °C 16 A | (380 / 440 V) 40 °C 20 A | (380 / 440 V) 55 °C 16 A | (690 V) 40 °C 6 A | (690 V) 55 °C 6 A
Rated Operational Current AC-3 (Ie)
(230 V) 55°C 12 A | (400 V) 55 °C 12 A | (500 V) 55 °C 9 A | (690 V) NO 55°C 3.5 A
Rated Operational Current AC-15 (Ie)
(24 V) 4 A | (120 V) 4 A | (500 V) 2 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 2.5 A | (110 V) 0.7 A | (220 / 240 V) 0.4 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 3 kW | (400 V) Three Phase 5.5 kW | (500 V) Three Phase 5.5 kW | (690 V) Three Phase, NO 3 kW
Rated Breaking Capacity AC-3
8 x Ie / AC-3
Rated Making Capacity AC-3
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A
Rated Insulation Voltage (Ui)
690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV | Main Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-15) 600 cycles per hour | (AC-3) 600 cycles per hour | (DC-1) 600 cycles per hour | (DC-13) 600 cycles per hour | (DC-3) 600 cycles per hour
Mechanical Durability
Nr. Operations 10000000 cycle
Minimum Switching Capacity
Auxiliary Circuit 17 V | Auxiliary Circuit 5 mA
Coil Operating Limits
(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)
60 V DC
Coil Consumption
Average Holding Value DC 3.5 W | Average Pull-in Value DC 3.5 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.4 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm² | Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | Flexible 1/2x 1 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm² | Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | Flexible 1/2x 1 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm² | Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | Flexible 1/2x 1 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm | Main Circuit 9 mm
Degree of Protection
Auxiliary Circuit Terminals IP20 | Control Circuit Terminals IP20 | Main Circuit Terminals IP20
Recommended Screw Driver
M3 | Pozidriv 1
Tightening Torque
Auxiliary Circuit 0.8 ... 1.1 N·m | Control Circuit 0.8 ... 1.1 N·m | Main Circuit 0.8 ... 1.1 N·m
Terminal Type
Screw Terminals
Mini Contactor Type
Mini Contactor
Product Name
Mini Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
General Use Rating UL/CSA
(600 V AC) 16 A
Horsepower Rating UL/CSA
(115 V AC) Single Phase 0.75 Hp | (200 V AC) Three Phase 2 Hp | (220 ... 240 V AC) Three Phase 3 Hp | (230 V AC) Single Phase 1.5 Hp | (440 ... 480 V AC) Three Phase 5 Hp | (550 ... 600 V AC) Three Phase 5 Hp
Connecting Capacity Main Circuit UL/CSA
Stranded 1/2x 22-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Stranded 1/2x 22-10 AWG
Contact Rating UL/CSA
A600
Tightening Torque UL/CSA
Auxiliary Circuit 7 in·lb | Control Circuit 7 in·lb | Main Circuit 7 in·lb
Full Load Amps Motor Use
(115 V AC) Single Phase 13.8 A | (200 V AC) Three Phase 7.8 A | (220 ... 240 V AC) Three Phase 9.6 A | (230 V AC) Single Phase 10 A | (440 ... 480 V AC) Three Phase 7.6 A | (550 ... 600 V AC) Three Phase 6.1 A
Ambient Air Temperature
Operation -25 ... +55 °C | Storage -40 ... +80 °C
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Resistance to Vibrations
5g 5 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End Of Life Instruction B(C)6, B(C)7, K(C)6, VB(C)6, VB(C)7
Environmental Product Declaration - EPD
Environmental Product Declaration PEP B(C)6, B(C)7 (EN)
A2L Certificate – IEC
A2L Certificate - B6-, B7-, K6- series, CA6, CAF6 - Mini Contactor
BV Certificate
BV Certificate - ESB24, ESB40, ESB63, EH04, B6, B7, EH04 - Installation Contactor
CB Certificate
CB Certificate - B6, BC6, VB6, VBC6, B7, BC7, VB7, VBC7 - Mini Contactor
CQC Certificate
CQC Certificate, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
Declaration of Conformity - CE
EU Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
Declaration of Conformity - UKCA
UK Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
DNV GL Certificate
DNV Certificate - B6, B7 - Mini Contactor
EAC Certificate
EAC Certificate - B6, BC6, B6S, VB6,B7, BC7, B7D, B7S, VB7, TBC7, ESB24, EN24, ESB40, EN40, ESB63 - Contactors
KC Certificate
KC Certificate - B6, B7
LR Certificate
LR Certificate - B6, B7 - Mini Contactor
RMRS Certificate
RMRS Certificate - B6, BC6, B7, BC7, VB6, VBC6, VB7, VBC7 - Mini Contactor
UL Certificate
UL Certificate of Compliance - B6, B7 - Mini Contactor
Package Level 1 Units
box 10 piece
Package Level 1 Width
115 mm
Package Level 1 Depth / Length
280 mm
Package Level 1 Height
54 mm
Package Level 1 Gross Weight
1.82 kg
Package Level 1 EAN
4013614418204
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: The BC7-30-01 uses a three-pole main circuit with three NO contacts and one NC auxiliary contact, enabling full control of 3-phase loads with reduced wiring and improved control reliability, which translates to smoother start/stop sequences in conveyors and HVAC fans. Application: ideal for compact motor control panels where reliability and space are at a premium. Feature → Business Impact → Application: A 60 V DC coil with low coil consumption (3.5 W holding and pull-in) minimizes power loss, lowers heat generation, and reduces energy costs in long-running control circuits. Application: suitable for control circuits in building automation and process equipment. Feature → Business Impact → Application: Screw terminals and DIN rail mounting (TH35-15 or TH35-7.5) simplify installation, enable clean wiring schemes, and support quick field upgrades. Application: preferred for modular panels in industrial automation. Feature → Business Impact → Application: Rated operational currents across AC-1 and AC-3, plus a robust mechanical life of 10 million cycles, deliver predictable performance and extended service intervals. Application: suitable for high-cycle environments like packaging lines and material handling. Feature → Business Impact → Application: Comprehensive standards and certifications (CE, UL/CSA, CCC, RoHS) ensure regulatory compliance across global markets, reducing risk and accelerating project approvals. Application: essential for multinational installations and OEM deployments. Feature → Business Impact → Application: Compact dimensions (52.5 mm width, 46.7 mm depth, 57.5 mm height) and a weight of 0.175 kg provide a space-efficient solution for control cabinets, enabling denser panel layouts and easier serviceability. Application: ideal for retrofits and new builds in space-constrained automation projects.
Get a Quick Quote for a ABB GJL1313001R0013
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB GJL1313001R0013?
Enquire Now
FAQs
The BC7-30-01 is designed for DIN rail mounting using TH35-15 or TH35-7.5 rails, standard in many control cabinets. This enables rapid installation, scalable panel layouts, and straightforward field upgrades without special tools. For larger assemblies, wall mounting remains possible with compatible brackets, preserving versatility in compact automation environments.
Rated operational current for AC-3 is 12 A at 230 or 400 V (55 °C), 9 A at 500 V, and 3.5 A at 690 V when NO contacts are used. Short-time withstand current (Icw) is 96 A at 40 °C in free air from a cold state for a 10 s interval. These figures support reliable motor control within the unit’s 5.5 kW AC-3/20 A AC-1 envelope.
Yes. Its 3-pole main contacts with 20 A AC-1 and 12 A AC-3 ratings at common voltages, plus a 60 V DC control coil, make it well-suited for HVAC fan starters and small conveyors. The compact footprint and DIN rail mounting simplify integration into modern automation panels without sacrificing motor control performance.
The BC7-30-01 carries CE marking, UL/CSA listings, and CB certification, along with RoHS compliance. These certifications support cross-border deployments, reduce the need for regional redesigns, and help OEMs meet customer and regulatory expectations for safety and environmental responsibility.
With a mechanical durability rating of 10 million cycles and a low coil power of 3.5 W, the BC7-30-01 minimizes wear and energy consumption, reducing maintenance intervals and energy costs. For ROI, consider reduced panel size, fewer wiring errors, and long service life in high-cycle environments like material handling or packaging lines.