ABB BC7-30-01 Mini Contactor - 48 V DC Coil, UL/CSA

Part Number: GJL1313001R1016
Manufacturer
ABB
Part number
GJL1313001R1016

Quick Summary

ABB BC7-30-01 Mini Contactor is a compact 3-pole device that controls 3-phase loads in industrial and commercial automation. Installers struggle with crowded panels and complex wiring; this mini contactor delivers reliable switching in a small footprint. The unit complies with IEC/EN 60947-1 and 60947-4-1, UL/CSA standards, and CE/UKCA markings, supporting global implementation. With screw terminals and optional DIN rail mounting, it speeds installation and reduces field wiring errors, while the 48 V DC coil keeps control circuits safe and responsive. For engineers seeking space-efficient motor control in HVAC, pumps, or conveyors, this device offers predictable performance and long service life.

Product Information

Extended Description

GJL1313001R1016 ABB: The BC7-30-01 mini contactor is a compact 3 pole contactor with 1 auxiliary contact and screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
2CDC102047M6801
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing - B6 / BC6 / B7 / BC7 / K6 / KC6
Product Net Width
52.5 mm
Product Net Depth / Length
46.7 mm
Product Net Height
57.5 mm
Product Net Weight
0.175 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1 | IEC/EN 60947-4-1 | IEC/EN 60947-5-1 | UL 60947-1 | UL 60947-4-1 | IEC 60335-2-40 A2L
Rated Operational Voltage
Auxiliary Circuit 690 V AC | Auxiliary Circuit 250 V DC | Main Circuit 690 V AC | Main Circuit 220 V DC
Rated Frequency (f)
Control Circuit DC | Main Circuit 50 Hz | Main Circuit 60 Hz | Main Circuit DC
Conventional Free-air Thermal Current (Ith)
Main Circuit 20 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 40 °C 20 A | (220 / 240 V) 55 °C 16 A | (380 / 440 V) 40 °C 20 A | (380 / 440 V) 55 °C 16 A | (690 V) 40 °C 6 A | (690 V) 55 °C 6 A
Rated Operational Current AC-3 (Ie)
(230 V) 55°C 12 A | (400 V) 55 °C 12 A | (500 V) 55 °C 9 A | (690 V) NO 55°C 3.5 A
Rated Operational Current AC-15 (Ie)
(24 V) 4 A | (120 V) 4 A | (500 V) 2 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 2.5 A | (110 V) 0.7 A | (220 / 240 V) 0.4 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 3 kW | (400 V) Three Phase 5.5 kW | (500 V) Three Phase 5.5 kW | (690 V) Three Phase, NO 3 kW
Rated Breaking Capacity AC-3
8 x Ie / AC-3
Rated Making Capacity AC-3
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A
Rated Insulation Voltage (Ui)
690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV | Main Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-15) 600 cycles per hour | (AC-3) 600 cycles per hour | (DC-1) 600 cycles per hour | (DC-13) 600 cycles per hour | (DC-3) 600 cycles per hour
Mechanical Durability
Nr. Operations 10000000 cycle
Minimum Switching Capacity
Auxiliary Circuit 17 V | Auxiliary Circuit 5 mA
Coil Operating Limits
(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)
48 V DC
Coil Consumption
Average Holding Value DC 3.5 W | Average Pull-in Value DC 3.5 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.4 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm² | Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | Flexible 1/2x 1 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm² | Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | Flexible 1/2x 1 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm² | Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | Flexible 1/2x 1 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Wire Stripping Length
Auxiliary Circuit 9 mm | Main Circuit 9 mm
Degree of Protection
Auxiliary Circuit Terminals IP20 | Control Circuit Terminals IP20 | Main Circuit Terminals IP20
Recommended Screw Driver
M3 | Pozidriv 1
Tightening Torque
Auxiliary Circuit 0.8 ... 1.1 N·m | Control Circuit 0.8 ... 1.1 N·m | Main Circuit 0.8 ... 1.1 N·m
Terminal Type
Screw Terminals
Mini Contactor Type
Mini Contactor
Product Name
Mini Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
General Use Rating UL/CSA
(600 V AC) 16 A
Horsepower Rating UL/CSA
(115 V AC) Single Phase 0.75 Hp | (200 V AC) Three Phase 2 Hp | (220 ... 240 V AC) Three Phase 3 Hp | (230 V AC) Single Phase 1.5 Hp | (440 ... 480 V AC) Three Phase 5 Hp | (550 ... 600 V AC) Three Phase 5 Hp
Connecting Capacity Main Circuit UL/CSA
Stranded 1/2x 22-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Stranded 1/2x 22-10 AWG
Contact Rating UL/CSA
A600
Tightening Torque UL/CSA
Auxiliary Circuit 7 in·lb | Control Circuit 7 in·lb | Main Circuit 7 in·lb
Full Load Amps Motor Use
(115 V AC) Single Phase 13.8 A | (200 V AC) Three Phase 7.8 A | (220 ... 240 V AC) Three Phase 9.6 A | (230 V AC) Single Phase 10 A | (440 ... 480 V AC) Three Phase 7.6 A | (550 ... 600 V AC) Three Phase 6.1 A
Ambient Air Temperature
Operation -25 ... +55 °C | Storage -40 ... +80 °C
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Resistance to Vibrations
5g 5 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End Of Life Instruction B(C)6, B(C)7, K(C)6, VB(C)6, VB(C)7
Environmental Product Declaration - EPD
Environmental Product Declaration PEP B(C)6, B(C)7 (EN)
A2L Certificate – IEC
A2L Certificate - B6-, B7-, K6- series, CA6, CAF6 - Mini Contactor
BV Certificate
BV Certificate - ESB24, ESB40, ESB63, EH04, B6, B7, EH04 - Installation Contactor
CB Certificate
CB Certificate - B6, BC6, VB6, VBC6, B7, BC7, VB7, VBC7 - Mini Contactor
CQC Certificate
CQC Certificate, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
Declaration of Conformity - CE
EU Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
Declaration of Conformity - UKCA
UK Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
DNV GL Certificate
DNV Certificate - B6, B7 - Mini Contactor
EAC Certificate
EAC Certificate - B6, BC6, B6S, VB6,B7, BC7, B7D, B7S, VB7, TBC7, ESB24, EN24, ESB40, EN40, ESB63 - Contactors
KC Certificate
KC Certificate - B6, B7
LR Certificate
LR Certificate - B6, B7 - Mini Contactor
RMRS Certificate
RMRS Certificate - B6, BC6, B7, BC7, VB6, VBC6, VB7, VBC7 - Mini Contactor
UL Certificate
UL Certificate of Compliance - B6, B7 - Mini Contactor
Package Level 1 Units
box 10 piece
Package Level 1 Width
115 mm
Package Level 1 Depth / Length
280 mm
Package Level 1 Height
54 mm
Package Level 1 Gross Weight
1.82 kg
Package Level 1 EAN
4013614418303
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4763 >> Power contactor, DC switching
Feature: Compact 3-pole design with 3 main NO contacts and 1 NC auxiliary contact. Business Impact: Enables reliable control of three-phase loads in a reduced panel footprint, lowering enclosure size and wiring complexity. Application: Ideal for space-constrained control cabinets in industrial automation. Feature: 48 V DC coil with low energy consumption (3.5 W nominal hold/pull-in). Business Impact: Reduces heat generation and energy cost in continuous-duty control circuits, enhancing energy efficiency and reliability. Application: Continuous motor control and signal switching in industrial equipment. Feature: Screw terminals and DIN rail mounting (TH35-15 / TH35-7.5). Business Impact: Streamlines installation, improves mechanical robustness, and simplifies field wiring, cutting commissioning time. Application: Retrofit and new-panel builds in manufacturing lines. Feature: Wide main circuit ratings up to 690 V and I_e ratings for AC-3 and AC-1. Business Impact: Supports high-voltage motor control with predictable switching performance and protective margins. Application: HVAC drives, pumps, conveyors, and machine tools. Feature: IP20 protection on terminals and robust mechanical durability (10,000,000 cycles). Business Impact: Ensures reliability in harsh environments and long service life, reducing maintenance intervals. Application: Industrial automation panels, power distribution enclosures, and modular control racks. Feature: Comprehensive certifications (IEC/EN 60947-1, 60947-4-1; UL/CSA; CE/UKCA). Business Impact: Facilitates global deployment, regulatory compliance, and customer approvals. Application: Global manufacturing operations and cross-border projects.

Get a Quick Quote for a ABB GJL1313001R1016

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB GJL1313001R1016? Enquire Now

FAQs

The BC7-30-01 supports DIN rail mounting on TH35-15 or TH35-7.5 rails and can be wall-mounted if needed. Its compact 52.5 mm width and 46.7 mm depth suit space-constrained panels while maintaining robust screw-terminal wiring for reliable field connections. This mounting flexibility simplifies retrofits and new builds alike, reducing installation time and panel depth requirements.
Main circuit is rated up to 690 V AC with 3-pole operation and a rated operating current suitable for AC-3 and AC-1 configurations. Specifically, AC-3 ratings include 12 A at 230 to 400 V and 9 A at 500 V, with a 3.5 A NO at 690 V. The auxiliary circuit uses 48 V DC control, with 6 kV impulse withstand and IP20 terminal protection.
Yes. The coil operates at 48 V DC with an average holding value of 3.5 W and a pull-in value of 3.5 W, delivering low heat generation and energy efficiency in continuous-duty control. This makes it well-suited for frequent switching in automated processes, reducing thermal stress on panels and improving reliability over time.
The device carries IEC/EN 60947-1 and 60947-4-1 approvals, UL/CSA listings, and CE/UKCA markings. This certification suite supports safe integration into European, UK, and North American systems, streamlining procurement for multinational projects and ensuring conformity with essential safety and performance standards.
Installation benefits include screw-terminal wiring for quick, solid connections and flexible DIN rail mounting to minimize panel space. The device’s 10,000,000 mechanical cycles and IP20 protection reduce maintenance needs and replacement risk. Coupled with low coil power and high AC-3 capacity, this translates to lower energy consumption, shorter downtime, and a faster return on investment in automation projects.