ABB GJL1313003R0104 Mini Contactor - Flat-Pin Connections
Part Number: GJL1313003R0104
Quick Summary
ABB GJL1313003R0104 mini contactor provides reliable switching for 3‑phase loads in industrial control panels. In tight spaces, its compact form factor minimizes installation footprint and reduces coil noise and energy waste. This device carries CE and UL/CSA approvals and IEC 60947-1/4 compliance, with IP20 protection for front and main terminals, ensuring safe operation in commercial environments. The 110–125 V DC coil and flat-pin connections simplify wiring and retrofit projects, while rail mounting compatibility (TH35-15/TH35-7.5) speeds installation and service. For OEMs and panel builders, this mini contactor delivers dependable control with long mechanical life and predictable maintenance costs.
Product Information
Extended Description
GJL1313003R0104 ABB: The BC7-30-10-F mini contactor is a compact 3 pole contactor with 1 auxiliary contact and flat pin connection. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
2CDC102047M6801
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing - B6 / BC6 / B7 / BC7 / K6 / KC6 (-F)
Product Net Width
52.5 mm
Product Net Depth / Length
46.7 mm
Product Net Height
57.5 mm
Product Net Weight
0.17 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1 | IEC/EN 60947-4-1 | IEC/EN 60947-5-1 | UL 60947-1 | UL 60947-4-1 | IEC 60335-2-40 A2L
Rated Operational Voltage
Auxiliary Circuit 690 V AC | Auxiliary Circuit 250 V DC | Main Circuit 690 V AC | Main Circuit 220 V DC
Rated Frequency (f)
Control Circuit DC | Main Circuit 50 Hz | Main Circuit 60 Hz | Main Circuit DC
Conventional Free-air Thermal Current (Ith)
Main Circuit 20 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 40 °C 20 A | (220 / 240 V) 55 °C 16 A | (380 / 440 V) 40 °C 20 A | (380 / 440 V) 55 °C 16 A | (690 V) 40 °C 6 A | (690 V) 55 °C 6 A
Rated Operational Current AC-3 (Ie)
(230 V) 55°C 12 A | (400 V) 55 °C 12 A | (500 V) 55 °C 9 A | (690 V) NO 55°C 3.5 A
Rated Operational Current AC-15 (Ie)
(24 V) 4 A | (120 V) 4 A | (500 V) 2 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 2.5 A | (110 V) 0.7 A | (220 / 240 V) 0.4 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 3 kW | (400 V) Three Phase 5.5 kW | (500 V) Three Phase 5.5 kW | (690 V) Three Phase, NO 3 kW
Rated Breaking Capacity AC-3
8 x Ie / AC-3
Rated Making Capacity AC-3
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A
Rated Insulation Voltage (Ui)
690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV | Main Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-15) 600 cycles per hour | (AC-3) 600 cycles per hour | (DC-1) 600 cycles per hour | (DC-13) 600 cycles per hour | (DC-3) 600 cycles per hour
Mechanical Durability
Nr. Operations 10000000 cycle
Minimum Switching Capacity
Auxiliary Circuit 17 V | Auxiliary Circuit 5 mA
Coil Operating Limits
(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)
110 ... 125 V DC
Coil Consumption
Average Holding Value DC 3.5 W | Average Pull-in Value DC 3.5 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.4 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Degree of Protection
Auxiliary Circuit Terminals IP20 | Control Circuit Terminals IP20 | Main Circuit Terminals IP20
Terminal Type
Flat-Pin Connections
Mini Contactor Type
Mini Contactor
Product Name
Mini Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
General Use Rating UL/CSA
(600 V AC) 16 A
Horsepower Rating UL/CSA
(115 V AC) Single Phase 0.75 Hp | (200 V AC) Three Phase 2 Hp | (220 ... 240 V AC) Three Phase 3 Hp | (230 V AC) Single Phase 1.5 Hp | (440 ... 480 V AC) Three Phase 5 Hp | (550 ... 600 V AC) Three Phase 5 Hp
Contact Rating UL/CSA
A600
Full Load Amps Motor Use
(115 V AC) Single Phase 13.8 A | (200 V AC) Three Phase 7.8 A | (220 ... 240 V AC) Three Phase 9.6 A | (230 V AC) Single Phase 10 A | (440 ... 480 V AC) Three Phase 7.6 A | (550 ... 600 V AC) Three Phase 6.1 A
Ambient Air Temperature
Operation -25 ... +55 °C | Storage -40 ... +80 °C
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Resistance to Vibrations
5g 5 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End Of Life Instruction B(C)6-F, B(C)7-F, K(C)6-F, VB(C)6-F, VB(C)7-F
Environmental Product Declaration - EPD
Environmental Product Declaration PEP B(C)6, B(C)7 (EN)
A2L Certificate – IEC
A2L Certificate - B6-, B7-, K6- series, CA6, CAF6 - Mini Contactor
BV Certificate
BV Certificate - ESB24, ESB40, ESB63, EH04, B6, B7, EH04 - Installation Contactor
CB Certificate
CB Certificate - B6, BC6, VB6, VBC6, B7, BC7, VB7, VBC7 - Mini Contactor
CQC Certificate
CQC Certificate, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
cURus Certificate
cUL_E191658
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
Declaration of Conformity - CE
EU Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
Declaration of Conformity - UKCA
UK Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
DNV GL Certificate
DNV Certificate - B6, B7 - Mini Contactor
EAC Certificate
EAC Certificate - B6, BC6, B6S, VB6,B7, BC7, B7D, B7S, VB7, TBC7, ESB24, EN24, ESB40, EN40, ESB63 - Contactors
KC Certificate
KC Certificate - B6, B7
LR Certificate
LR Certificate - B6, B7 - Mini Contactor
RMRS Certificate
RMRS Certificate - B6, BC6, B7, BC7, VB6, VBC6, VB7, VBC7 - Mini Contactor
UL Certificate
UL Certificate of Compliance - B6, B7 (Pin/Faston) - Mini Contactor
Package Level 1 Units
box 10 piece
Package Level 1 Width
115 mm
Package Level 1 Depth / Length
280 mm
Package Level 1 Height
54 mm
Package Level 1 Gross Weight
1.77 kg
Package Level 1 EAN
4013614418518
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4763 >> Power contactor, DC switching
Feature: Three main NO contacts with one auxiliary NO contact enable clean three‑phase motor control in a compact footprint. Business Impact: Supports AC‑3 loads up to 5.5 kW, reducing space and making wiring simpler in control cabinets. Application: Ideal for small to mid‑sized machinery and building automation where reliability and compactness matter. Feature: DC coil rated 110–125 V with coil consumption of 3.5 W holding and pull‑in. Business Impact: Lowers energy draw and heat in the control cabinet, improving overall efficiency and cooling costs. Application: Suitable for direct DC control circuits in industrial panels and automation systems. Feature: Flat‑pin terminal connections with DIN rail mounting (TH35‑15/TH35‑7.5) and IP20 protection. Business Impact: Enables quick wiring and fast, secure mounting on standard rails, reducing installation time and field wiring errors. Application: Fits standard industrial enclosures and panel assemblies across global facilities. Feature: Mechanical durability rated at 10 million cycles and modular DIN rail compatibility. Business Impact: Extends service life and reduces maintenance intervals, delivering lower total cost of ownership. Application: Harsh or high‑cycle environments such as conveyors, pumps, and ventilation systems. Feature: Comprehensive standards and certifications (IEC/EN 60947, UL/CSA, CE, UKCA, CB, CCC, EAC). Business Impact: Regulatory alignment across regions minimizes procurement risk and accelerates global deployments. Application: Suitable for multi‑site projects requiring cross‑border compliance.
Get a Quick Quote for a ABB GJL1313003R0104
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB GJL1313003R0104?
Enquire Now
FAQs
This mini contactor is designed for DIN rail mounting using TH35-15 or TH35-7.5 rails. Wire the 3 main NO contacts and 1 NO auxiliary contact using flat-pin terminals for quick, secure connections. The coil is DC 110–125 V, and the device complies with IP20 protection for safe cabinet installation.
Rated AC-3 power handling reaches up to 5.5 kW at 400–500 V, and up to 3 kW at 230 V, depending on your supply. The unit features 3 main NO contacts and is suitable for motor control in light industrial equipment with up to 20 A rated operational current in many configurations.
Yes. Its compact 3P design, low coil power, and robust IEC/UL certifications make it well suited for commercial buildings and industrial equipment requiring reliable control of three‑phase loads, such as fans, pumps, and small conveyors, while fitting neatly into standard control cabinets.
The device carries CE, UL/CSA, and IEC/EN 60947-1, 60947-4-1 compliance, with IP20 protection. It also aligns with multiple regional declarations (UKCA, CCC, EAC) and a broad certification suite, reducing regulatory risk for global deployments and ensuring safe, compliant operation in diverse environments.
With a mechanical durability of up to 10 million cycles and a coil that consumes 3.5 W during hold and pull-in, it delivers long service life with minimal energy loss. The flat-pin connections and DIN rail compatibility also simplify field servicing and replacement, contributing to lower maintenance time and cost.