ABB BC7-30-01-F-16 Mini Contactor - Flat-Pin Connections

Part Number: GJL1313003R1016
Manufacturer
ABB
Part number
GJL1313003R1016

Quick Summary

ABB BC7-30-01-F-16 Mini Contactor is a compact 3-pole device used to reliably switch three-phase loads in industrial control panels. When space is tight and uptime matters, these small but capable contactors help keep control cabinets streamlined without sacrificing performance. They carry CE and UL/CSA listings with IP20 protection and IEC/EN 60947-1 and 60947-4-1 compliance, supporting global installations. In addition to compact size, this unit offers a 48 V DC control coil and flat-pin terminals, delivering easy wiring, reduced assembly time, and dependable operation in demanding environments. For building automation, machine control, and HVAC applications, the combination of small footprint and robust performance translates to tangible efficiency and maintenance advantages.

Product Information

Extended Description

GJL1313003R1016 ABB: The BC7-30-01-F mini contactor is a compact 3 pole contactor with 1 auxiliary contact and flat pin connection. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
2CDC102047M6801
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing - B6 / BC6 / B7 / BC7 / K6 / KC6 (-F)
Product Net Width
52.5 mm
Product Net Depth / Length
46.7 mm
Product Net Height
57.5 mm
Product Net Weight
0.17 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1 | IEC/EN 60947-4-1 | IEC/EN 60947-5-1 | UL 60947-1 | UL 60947-4-1 | IEC 60335-2-40 A2L
Rated Operational Voltage
Auxiliary Circuit 690 V AC | Auxiliary Circuit 250 V DC | Main Circuit 690 V AC | Main Circuit 220 V DC
Rated Frequency (f)
Control Circuit DC | Main Circuit 60 Hz | Main Circuit 50 Hz | Main Circuit DC
Conventional Free-air Thermal Current (Ith)
Main Circuit 20 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 40 °C 20 A | (220 / 240 V) 55 °C 16 A | (380 / 440 V) 40 °C 20 A | (380 / 440 V) 55 °C 16 A | (690 V) 40 °C 6 A | (690 V) 55 °C 6 A
Rated Operational Current AC-3 (Ie)
(230 V) 55°C 12 A | (400 V) 55 °C 12 A | (500 V) 55 °C 9 A | (690 V) NO 55°C 3.5 A
Rated Operational Current AC-15 (Ie)
(24 V) 4 A | (120 V) 4 A | (500 V) 2 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 2.5 A | (110 V) 0.7 A | (220 / 240 V) 0.4 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 3 kW | (400 V) Three Phase 5.5 kW | (500 V) Three Phase 5.5 kW | (690 V) Three Phase, NO 3 kW
Rated Breaking Capacity AC-3
8 x Ie / AC-3
Rated Making Capacity AC-3
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A
Rated Insulation Voltage (Ui)
690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV | Main Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-15) 600 cycles per hour | (AC-3) 600 cycles per hour | (DC-1) 600 cycles per hour | (DC-13) 600 cycles per hour | (DC-3) 600 cycles per hour
Mechanical Durability
Nr. Operations 10000000 cycle
Minimum Switching Capacity
Auxiliary Circuit 17 V | Auxiliary Circuit 5 mA
Coil Operating Limits
(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)
48 V DC
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.4 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Degree of Protection
Auxiliary Circuit Terminals IP20 | Control Circuit Terminals IP20 | Main Circuit Terminals IP20
Terminal Type
Flat-Pin Connections
Mini Contactor Type
Mini Contactor
Product Name
Mini Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
General Use Rating UL/CSA
(600 V AC) 16 A
Horsepower Rating UL/CSA
(115 V AC) Single Phase 0.75 Hp | (200 V AC) Three Phase 2 Hp | (220 ... 240 V AC) Three Phase 3 Hp | (230 V AC) Single Phase 1.5 Hp | (440 ... 480 V AC) Three Phase 5 Hp | (550 ... 600 V AC) Three Phase 5 Hp
Contact Rating UL/CSA
A600
Full Load Amps Motor Use
(115 V AC) Single Phase 13.8 A | (200 V AC) Three Phase 7.8 A | (220 ... 240 V AC) Three Phase 9.6 A | (230 V AC) Single Phase 10 A | (440 ... 480 V AC) Three Phase 7.6 A | (550 ... 600 V AC) Three Phase 6.1 A
Ambient Air Temperature
Operation -25 ... +55 °C | Storage -40 ... +80 °C
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Resistance to Vibrations
5g 5 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End Of Life Instruction B(C)6-F, B(C)7-F, K(C)6-F, VB(C)6-F, VB(C)7-F
Environmental Product Declaration - EPD
Environmental Product Declaration PEP B(C)6, B(C)7 (EN)
A2L Certificate – IEC
A2L Certificate - B6-, B7-, K6- series, CA6, CAF6 - Mini Contactor
BV Certificate
BV Certificate - ESB24, ESB40, ESB63, EH04, B6, B7, EH04 - Installation Contactor
CB Certificate
CB Certificate - B6, BC6, VB6, VBC6, B7, BC7, VB7, VBC7 - Mini Contactor
CQC Certificate
CQC Certificate, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
cURus Certificate
cUL_E191658
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
Declaration of Conformity - CE
EU Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
Declaration of Conformity - UKCA
UK Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
DNV GL Certificate
DNV Certificate - B6, B7 - Mini Contactor
EAC Certificate
EAC Certificate - B6, BC6, B6S, VB6,B7, BC7, B7D, B7S, VB7, TBC7, ESB24, EN24, ESB40, EN40, ESB63 - Contactors
KC Certificate
KC Certificate - B6, B7
LR Certificate
LR Certificate - B6, B7 - Mini Contactor
RMRS Certificate
RMRS Certificate - B6, BC6, B7, BC7, VB6, VBC6, VB7, VBC7 - Mini Contactor
UL Certificate
UL Certificate of Compliance - B6, B7 (Pin/Faston) - Mini Contactor
Package Level 1 Units
box 10 piece
Package Level 1 Width
115 mm
Package Level 1 Depth / Length
280 mm
Package Level 1 Height
54 mm
Package Level 1 Gross Weight
1.77 kg
Package Level 1 EAN
4013614418549
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: 48 V DC coil enables fast, reliable coil energization with low power draw, reducing control circuit load and energy consumption in panel installations; Application: motor control and signal switching where DC control is preferred. Feature → Three main normally open contacts (NO) provide straightforward, high-reliability switching of three-phase loads up to 5.5 kW (AC-3) at typical voltages; Business Impact → Higher load handling with compact size reduces panel footprint and wiring complexity; Application → Machine controls and conveyor systems. Feature → One normally closed auxiliary contact (NC) supports signaling and interlocking schemes; Business Impact → Simplified logic for interlock/feedback without adding separate components; Application → Safety interlocks in automated lines. Feature → Flat-pin connections simplify wiring harnessing and reduce installation time; Business Impact → Faster assembly and lower torque requirements, improving field service efficiency; Application → OEM panel builds and retrofit projects. Feature → DIN rail mounting compatibility (TH35-15 and TH35-7.5) enables flexible, space-saving installation; Business Impact → Faster deployment and easier maintenance with standardized mounting; Application → Control cabinets in industrial facilities. Feature → IEC/EN 60947-1 | IEC/EN 60947-4-1 | UL 60947-1 | UL 60947-4-1 compliance plus IP20 protection; Business Impact → Certified safety and regulatory alignment across markets, lowering compliance risk; Application → Global product deployment in North America, Europe, and beyond. Feature → Mechanical durability rated at 10,000,000 cycles and rated insulation up to 690 V; Business Impact → Long service life and reduced replacement costs in high-cycle applications; Application → Robotic cells, packaging lines, and material handling systems.

Get a Quick Quote for a ABB GJL1313003R1016

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB GJL1313003R1016? Enquire Now

FAQs

The BC7-30-01-F-16 is designed for TH35-15 and TH35-7.5 DIN rails. Align the device with the rail, press down firmly until it snaps, and ensure the coil polarity is correct for DC operation. Use flat-pin terminals to simplify wiring, and verify adjacent clearances to prevent overheating. For installation in tight spaces, consider pre-wiring the auxiliary function and test the auxiliary NC circuit before commissioning.
The device supports AC-3 operation with rated operational currents depending on voltage and temperature, including up to 12 A at 230–400 V and up to 6 A at 690 V in higher temperature environments. It is rated for 60 Hz operation, with a maximum breaking capacity defined as 8 x Ie for AC-3. Design around 230 V or 400 V three-phase mains with appropriate fault protection and consider the 40–55 °C site temperatures specified.
Yes, the BC7-30-01-F-16 uses a 48 V DC control coil. Coil operating limits follow IEC 60947-4-1, typically 0.85 to 1.1 x Uc at temperatures up to 55 °C. This ensures reliable coil energization under specified ambient conditions. When designing with DC coils, ensure proper polarity, minimal voltage drop across wiring, and adequate derating for extended duty cycles.
The product is CE-marked and UL/CSA listed with multiple certificates including CB, UKCA, EN/IEC standards, and UL 60947-1 and UL 60947-4-1. It has IP20 protection for the main, control, and auxiliary terminals, and complies with RoHS, REACH, and CMRT declarations. These certifications support global deployment in industrial environments and help meet regulatory and safety requirements.
Follow recommended enclosure and ambient conditions, keep mirrors and contacts clean from dust, and avoid exposure to excessive vibration or moisture beyond IP20 ratings. Regularly inspect the coil connections and verify the integrity of flat-pin terminals. With a mechanical durability rating of 10,000,000 cycles, routine checks on mounting integrity and terminal torque help maintain peak performance and minimize downtime.