ABB GJL1313501R0005 Mini Contactor - IEC/UL 60947-4-1
Part Number: GJL1313501R0005
Quick Summary
ABB GJL1313501R0005 mini contactor is a compact motor control device designed for industrial loads up to 5.5 kW. In space-constrained panels, its small footprint and screw-terminal design reduce wiring complexity and installation time. This part carries CE and UL/CSA certifications with RoHS compliance and IP20 protection, ensuring safe, compliant operation in typical control environments. Its DIN rail mounting and low coil power translate to lower total cost of ownership, while robust mechanical life supports demanding manufacturing schedules. For engineers seeking reliable, efficient switching with straightforward maintenance, this mini contactor delivers predictable performance in commercial buildings and light industrial applications.
Product Information
Extended Description
GJL1313501R0005 ABB: The BC7-22-00 mini contactor is a compact 4 pole contactor with screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
2CDC102047M6801
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing - B6 / BC6 / B7 / BC7 / K6 / KC6
Product Net Width
52.5 mm
Product Net Depth / Length
46.7 mm
Product Net Height
57.5 mm
Product Net Weight
0.175 kg
Number of Main Contacts NO
2
Number of Main Contacts NC
2
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1 | IEC/EN 60947-4-1 | IEC/EN 60947-5-1 | UL 60947-1 | UL 60947-4-1 | IEC 60335-2-40 A2L
Rated Operational Voltage
Main Circuit 690 V AC | Main Circuit 220 V DC
Rated Frequency (f)
Control Circuit DC | Main Circuit 50 Hz | Main Circuit 60 Hz | Main Circuit DC
Conventional Free-air Thermal Current (Ith)
Main Circuit 20 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 40 °C 20 A | (220 / 240 V) 55 °C 16 A | (380 / 440 V) 40 °C 20 A | (380 / 440 V) 55 °C 16 A | (690 V) 40 °C 6 A | (690 V) 55 °C 6 A
Rated Operational Current AC-3 (Ie)
(230 V) 55°C 12 A | (400 V) 55 °C 12 A | (500 V) 55 °C 9 A | (690 V) NC 55°C 3.5 A | (690 V) NO 55°C 3.5 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 3 kW | (400 V) Three Phase 5.5 kW | (500 V) Three Phase 5.5 kW | (690 V) Three Phase, NC 3 kW | (690 V) Three Phase, NO 3 kW
Rated Breaking Capacity AC-3
8 x Ie / AC-3
Rated Making Capacity AC-3
10 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A
Rated Insulation Voltage (Ui)
690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-3) 600 cycles per hour | (DC-1) 600 cycles per hour | (DC-3) 600 cycles per hour
Mechanical Durability
Nr. Operations 10000000 cycle
Coil Operating Limits
(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)
220 ... 240 V DC
Coil Consumption
Average Holding Value DC 3.5 W | Average Pull-in Value DC 3.5 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.4 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm² | Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | Flexible 1/2x 1 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm² | Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | Flexible 1/2x 1 ... 2.5 mm² | Rigid 1/2x 1 ... 4 mm²
Wire Stripping Length
Main Circuit 9 mm
Degree of Protection
Control Circuit Terminals IP20 | Main Circuit Terminals IP20
Recommended Screw Driver
M3 | Pozidriv 1
Tightening Torque
Control Circuit 0.8 ... 1.1 N·m | Main Circuit 0.8 ... 1.1 N·m
Terminal Type
Screw Terminals
Mini Contactor Type
Mini Contactor
Product Name
Mini Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
General Use Rating UL/CSA
(600 V AC) 16 A
Horsepower Rating UL/CSA
(115 V AC) Single Phase 0.75 Hp | (200 V AC) Three Phase 2 Hp | (220 ... 240 V AC) Three Phase 3 Hp | (230 V AC) Single Phase 1.5 Hp | (440 ... 480 V AC) Three Phase 5 Hp | (550 ... 600 V AC) Three Phase 5 Hp
Connecting Capacity Main Circuit UL/CSA
Stranded 1/2x 22-10 AWG
Tightening Torque UL/CSA
Control Circuit 7 in·lb | Main Circuit 7 in·lb
Full Load Amps Motor Use
(115 V AC) Single Phase 13.8 A | (200 V AC) Three Phase 7.8 A | (220 ... 240 V AC) Three Phase 9.6 A | (230 V AC) Single Phase 10 A | (440 ... 480 V AC) Three Phase 7.6 A | (550 ... 600 V AC) Three Phase 6.1 A
Ambient Air Temperature
Operation -25 ... +55 °C | Storage -40 ... +80 °C
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Resistance to Vibrations
5g 5 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End Of Life Instruction B(C)6, B(C)7, K(C)6, VB(C)6, VB(C)7
Environmental Product Declaration - EPD
Environmental Product Declaration PEP B(C)6, B(C)7 (EN)
A2L Certificate – IEC
A2L Certificate - B6-, B7-, K6- series, CA6, CAF6 - Mini Contactor
BV Certificate
BV Certificate - ESB24, ESB40, ESB63, EH04, B6, B7, EH04 - Installation Contactor
CB Certificate
CB Certificate - B6, BC6, VB6, VBC6, B7, BC7, VB7, VBC7 - Mini Contactor
CQC Certificate
CQC Certificate, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
Declaration of Conformity - CE
EU Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
Declaration of Conformity - UKCA
UK Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
DNV GL Certificate
DNV Certificate - B6, B7 - Mini Contactor
EAC Certificate
EAC Certificate - B6, BC6, B6S, VB6,B7, BC7, B7D, B7S, VB7, TBC7, ESB24, EN24, ESB40, EN40, ESB63 - Contactors
KC Certificate
KC Certificate - B6, B7
LR Certificate
LR Certificate - B6, B7 - Mini Contactor
RMRS Certificate
RMRS Certificate - B6, BC6, B7, BC7, VB6, VBC6, VB7, VBC7 - Mini Contactor
UL Certificate
UL Certificate of Compliance - B6, B7 - Mini Contactor
Package Level 1 Units
box 10 piece
Package Level 1 Width
115 mm
Package Level 1 Depth / Length
280 mm
Package Level 1 Height
54 mm
Package Level 1 Gross Weight
1.82 kg
Package Level 1 EAN
4013614419072
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: The BC7-22-00 family uses a four-pole configuration with 2 NO and 2 NC contacts, enabling control of both forward and reverse or interlocking schemes in compact spaces. This yields simplified wiring, improved safety interlocks, and reduced panel depth, ideal for HVAC starters and small conveyors. Feature → Business Impact → Application: 20 A continuous current rating (AC-1/AC-3 dependent on voltage) at up to 690 V main circuit reduces the number of devices required in multi-load installations, cutting bill of materials and installation time. Feature → Business Impact → Application: DC control circuit with 220–240 V DC coil and 3.5 W holding/pull-in consumption minimizes energy use and reduces heat in the enclosure, improving reliability in harsh environments. Feature → Business Impact → Application: Screw terminals and wire-connector compatibility with 0.5–4 mm² conductors streamline field wiring and facilitate quick maintenance. Feature → Business Impact → Application: TH35-15 / TH35-7.5 DIN rail mounting supports fast, standardized installation in control cabinets, saving space and enhancing serviceability. Feature → Business Impact → Application: IP20 protection on both control and main circuit terminals safeguards against dust ingress and incidental contact, suitable for indoor electrical panels. Feature → Business Impact → Application: High mechanical durability (10,000,000 cycles) ensures long-term reliability in continuous operation, reducing replacement intervals for critical loads. Feature → Business Impact → Application: Compliance to IEC/EN and UL standards provides confidence for global deployments and cross-border procurement, with dimension and connection data available via Autodesk/2D drawings for CAD integration. Feature → Business Impact → Application: Dimensioned footprint (52.5 mm width, 46.7 mm depth, 57.5 mm height) offers predictable enclosure planning and cabinet layout optimization in factories and campuses.
Get a Quick Quote for a ABB GJL1313501R0005
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB GJL1313501R0005?
Enquire Now
FAQs
This mini contactor supports TH35-15 and TH35-7.5 DIN rail mounting per IEC 60715. Align the rail with the enclosure edge, snap the unit onto the rail, and verify the module is firmly seated. Wiring is then terminated at screw terminals with recommended conductor sizes specified in the technical data.
Main circuit rated up to 690 V AC with DC control circuit voltage of 220–240 V. Rated operational current AC-3 varies by voltage: up to 12 A at 230/400/500 V, with 3.5 W coil consumption for both pull-in and holding. The device also supports AC-1 ratings and provides a 4P, 2NO 2NC configuration.
Yes. The device is designed for main circuit voltages up to 690 V and provides AC-3 rated power for three-phase loads, delivering up to 5.5 kW at appropriate voltages. Its four-pole construction supports reliable switching of 3-phase loads with integrated safety margins.
The product carries CE and UL/CSA certifications, RoHS compliance, and is listed with IEC/EN 60947-4-1 and related standards. It also includes IP20 protection on terminals, confirming suitability for indoor panel installations and compliance with global electrical safety requirements.
Expect high durability with a mechanical life rating around 10,000,000 operations. Regular maintenance should focus on ensuring clean terminals, inspection of screw torque (0.8–1.1 N·m for main and control circuits), and verifying coil integrity. This reduces unexpected failures and extends service intervals in production environments.