Eaton Crouse-Hinds 1036 Throat Bushing - UL Certified
Part Number: 1036
Quick Summary
Eaton Crouse-Hinds throat bushing enables insulated, threaded entry for 2" rigid/IMC conduit into enclosures. Engineers often struggle with insulation degradation, moisture ingress, and NEC/CEC compliance during field installations. This part carries UL certification for rigid-IMC use in Ordinary/Non-Hazardous Locations, a 105°C rating, and an insulated malleable-iron body. Together with its threaded design and compact footprint, it supports safer, faster installations and lower maintenance across control panels and industrial enclosures. Its 2-inch trade size fits common conduit inventories, helping procurement streamline project sourcing.
Product Information
Extended Description
1036 Eaton Crouse-Hinds: Eaton Crouse-Hinds series throat bushing, Rigid/IMC, Insulated, Malleable iron, 105°C, Threaded, 2"
Product Name
Eaton Crouse-Hinds series throat bushing
Catalog Number
1036
Product Length/Depth
2.75 in
Product Height
0.88 in
Product Width
2.75 in
Product Weight
0.22 lb
UPC
784564110367
Area classification
Ordinary/Non-Hazardous Locations
Standards type
NEC/CEC
Conduit type
Rigid/IMC
Insulator
Insulated
Thread
Threaded
Trade size
2"
Material
Malleable iron
Temperature rating
105°C
Crouse-Hinds series Insulating and Throat Bushings - Rigid-IMC catalog page
Insulating and Throat Bushings - Rigid-IMC UL certification
Insulating and Throat Bushings - Rigid-IMC UL certification
Eaton Specification Sheet - 1036
Feature → Business Impact → Application: The throat bushing combines insulated construction in malleable iron with a threaded connection and a 2" trade size designed for rigid/IMC conduits. This delivers a robust moisture barrier and arc-tracking protection at enclosure entries, reducing insulation wear and maintenance costs over time. The practical result is fewer field reworks and longer service life for critical control panels and equipment housings in manufacturing facilities. Feature → Business Impact → Application: UL-listed design aligned with NEC/CEC standards and Ordinary/Non-Hazardous Location classification. This simplifies approvals, reduces compliance risk, and speeds project timelines. It is well suited for control rooms, switchgear, and panel boards in industrial plants where code compliance is mandatory. Feature → Business Impact → Application: Temperature rating of 105°C with insulated construction preserves conductor insulation in hot cabinet environments, minimizing performance degradation and rework. This makes it ideal for high-ambient spaces and equipment bays where enclosure heating is a concern. Feature → Business Impact → Application: Lightweight, compact 2" trade size with threaded, rigid/IMC compatibility and a 0.22 lb weight facilitates faster installations and easier inventory planning. It reduces handling time and space requirements in crowded electrical closets and retrofit projects.
Get a Quick Quote for a Eaton Crouse-Hinds 1036
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds 1036?
Enquire Now
FAQs
The 1036 throat bushing uses a threaded connection compatible with 2" trade-size rigid/IMC conduit. Installation involves threading the bushing into the enclosure knockout, aligning the conduit, and tightening to spec to ensure a secure, insulated seal. The malleable iron body provides robust mechanical support, while the insulated design minimizes conductor exposure and potential arcing at entry points.
Key specifications include 2" trade size, threaded connection, rigid/IMC compatibility, insulated construction, malleable iron material, and a 105°C temperature rating. The UL-listed designation for ordinary locations further informs reliability and compliance. Together these specs ensure durable insulation, protective ingress resistance, and stable performance in typical industrial environments.
Yes. The product is certified for Ordinary/Non-Hazardous Locations and adheres to NEC/CEC standards, with UL certification for rigid-IMC conduit fittings. This makes it appropriate for control panels, switchgear, and industrial enclosures in facilities where non-hazardous environment ratings and code compliance are required.
The 1036 throat bushing carries UL certification for rigid-IMC use, aligns with NEC/CEC standards, and is classified for Ordinary/Non-Hazardous Locations. These certifications validate safety, compliance, and interoperability with standard conduit fittings, which is crucial for audits, procurement souring, and project approvals in industrial facilities.
Using the insulated throat bushing reduces moisture ingress and insulation degradation, lowering maintenance intervals and rework costs. Its robust construction and UL/NEC/CEC compliance also shorten commissioning times and minimize downtime, delivering a favorable total cost of ownership in panel builds and field retrofits across manufacturing and process environments.