Eaton 12191000121 EXIT exit sign - IP66 IECEx/ATEX Zone 21

Part Number: 12191000121
Manufacturer
Eaton Crouse-Hinds
Part number
12191000121

Quick Summary

EXIT exit sign provides clear egress indication for industrial facilities. In hazardous locations, ambiguous signage can slow responses and elevate risk. This model delivers IP66 protection and IECEx/ATEX Zone 21 ratings, with ISO 7010 pictograms for consistent safety messaging. LED efficiency reduces energy use, while the wall-mount design streamlines installation in tight spaces. With a wide voltage range of 110-277 Vac or 110-250 Vdc, it supports both new construction and retrofit projects, and its polycarbonate housing stands up to demanding environments. Short downtime, predictable maintenance, and a robust, readable sign translate into improved safety and lower total cost of ownership across facilities.

Product Information

Extended Description

12191000121 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EXIT exit sign, Arrowhead right, Gray, LED, White letter color, Polycarbonate, Wall mount, Cover with silk-screen pictogram (arrow 3h), 2 x M20 metal thread, ISO 7010, 110-277 Vac, 110-250 Vdc
Product Name
Eaton's Crouse-Hinds series EXIT exit sign
Catalog Number
12191000121
Product Length/Depth
380.5 mm
Product Height
175 mm
Product Width
76 mm
Product Weight
2 kg
EAN
4250217484728
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX
IECEx/ATEX hazardous rating
Zone 21 Zone 1
Ingress protection (IP) ratings
IP66
Lamp type
LED
Exit sign designation
Arrowhead right
Type
ISO 7010
Trade size
2 x M20 metal thread
Special features
Includes cover with silk-screen pictogram (arrow 3h)
Voltage rating
110-277 Vac, 110-250 Vdc
Frequency rating
50-60 Hz
Letter color
White
Material
Polycarbonate
Housing finish color
Gray
Mounting
Wall
LED lamp technology delivers long life and low power consumption, reducing energy costs and maintenance cycles while maintaining high-contrast visibility in all lighting conditions. This translates to more reliable evacuations and lower lifecycle costs in busy production lines and warehouse environments. The IP66 enclosure and hazardous-location ratings (Zone 21/1) protect against dust and washdown processes, ensuring compliance and reducing the risk of sign failure in process industries. ISO 7010 compliant arrowhead right design provides standardized evacuation guidance, minimizing confusion during emergencies and speeding decision-making for operators and responders. The two M20 metal-thread entries and wall-mount configuration offer flexible wiring and fast installation, enabling retrofit compatibility with existing conduits and mounting boards. The rugged gray polycarbonate housing with white letter color improves readability in bright environments and supports durable operation in demanding industrial settings, while the wide voltage range simplifies design and stocking for engineers. This combination of features addresses common objections about signage upgrades by providing a single, compliant, long-lasting solution that supports safety programs and regulatory requirements across hazardous locations.

Get a Quick Quote for a Eaton Crouse-Hinds 12191000121

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds 12191000121? Enquire Now

FAQs

The 12191000121 is designed for wall mounting and offers two M20 metal threaded entries for flexible conduit or cable entry. This enables quick installation in corridors, control rooms, or along hazardous-area boundaries. The rugged polycarbonate housing and compact footprint help it fit in tight spaces while maintaining readability of the white letters against the gray housing. For retrofits, its wall-mount configuration reduces the need for ceiling work or new mounting brackets, lowering installation time and costs.
This exit sign supports a wide input range of 110-277 Vac or 110-250 Vdc with a frequency rating of 50-60 Hz, offering flexibility for diverse power architectures. Wiring should follow standard conduit practices using the two M20 entries for protected cable entry. The LED driver provides consistent luminosity across voltage variations, ensuring reliable visibility during power fluctuations common in industrial facilities.
Yes. The sign uses ISO 7010 compliant pictograms (arrow 3h) and declares an Arrowhead right designation. It carries IECEx/ATEX certification for Zone 21 and Zone 1 hazardous locations, and an IP66 rating, making it suitable for classified and hazardous environments such as chemical and petrochemical plants, minimizing compliance risk during inspections.
The unit is rated IP66 for ingress protection and is certified for hazardous locations under IECEx/ATEX with Zone 21 and Zone 1 ratings. It is designed for areas requiring certification for hazardous/classified locations, ensuring electrical safety, resistance to dust and water ingress, and dependable operation in challenging environments. Built for wall mounting with durable polycarbonate housing, it is reliable in industrial settings where maintenance windows are limited.
LED technology provides a longer service life with lower energy consumption compared with incandescent or fluorescent signs, reducing replacement and energy costs over time. The sign’s durable housing and IP66/Hazardous Location ratings lower maintenance required due to fewer repairs from washdowns or moisture exposure. A single SKU covering wide voltage ranges simplifies stocking and reduces downtime during upgrades, contributing to a favorable total cost of ownership for facilities with frequent safety-sign upgrades.