Eaton 12191030001 EXIT N Exit Sign - Zone 1/21 IP66
Part Number: 12191030001
Quick Summary
EXIT N exit sign by Eaton provides reliable emergency egress indication for hazardous locations in industrial facilities. In harsh environments, conventional signs fail due to moisture, dust, or unreliable power. This unit carries IECEx/ATEX certification for Zone 1 and Zone 21, IP66 ingress protection, and CE compliance, ensuring safe operation in demanding industrial settings. LED technology delivers high visibility with low energy consumption, while a self-contained battery system supports independent operation during power outages. With wall-mount installation and a rugged polycarbonate housing, it minimizes maintenance, reduces downtime, and supports compliant, long-term signaling in hazardous areas.
Product Information
Extended Description
12191030001 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EXIT N exit sign, Arrow right, Gray, LED, White letters, Polycarb, Wall mt, Cover with silk-screen pictogram (arrow 3h), battery, 1 x M20 plastic cable glands, 1 x M20 screw plug, DIN 4844, 110-277 Vac, 110-250 Vdc
Product Name
Eaton's Crouse-Hinds series EXIT N exit sign
Catalog Number
12191030001
Product Length/Depth
380.5 mm
Product Height
175 mm
Product Width
76 mm
Product Weight
2.5 kg
EAN
4250217412813
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX IEC
IECEx/ATEX hazardous rating
Zone 1 Zone 21
Ingress protection (IP) ratings
IP66
Lamp type
LED
Exit sign designation
Arrowhead right
Type
DIN 4844
Trade size
1 x M20 plastic cable glands, 1 x M20 screw plug
Special features
Includes cover with silk-screen pictogram (arrow 3h), self-contained battery system
Voltage rating
110-277 Vac, 110-250 Vdc
Frequency rating
50-60 Hz
Letter color
White
Material
Polycarbonate
Housing finish color
Gray
Mounting
Wall
Crouse-Hinds series CEAG EXIT/EXIT2 Nonmetallic LED Exit Signs catalog page
Crouse-Hinds series CEAG EXIT N Nonmetallic LED Exit Signs operating instructions
Feature – Hazardous-location readiness with IECEx/ATEX certification for Zone 1 and Zone 21, plus IP66 protection. Business Impact – Ensures regulatory compliance, reduces risk of non-conformance, and protects assets in chemical, petrochemical, and mining environments. Application – Ideal for industrial plants where aggressive environments and strict safety standards apply, enabling safe egress signage in hazardous spaces. Feature – LED illumination with 50-60 Hz operation and a wide voltage range of 110-277 Vac or 110-250 Vdc. Business Impact – Delivers bright, consistent visibility while lowering energy costs and extending lamp life. Application – Suitable for active signaling in continuous operation areas with variable power supply conditions. Feature – Self-contained battery system and silk-screen pictogram cover. Business Impact – Maintains operation during outages and simplifies installation with clear, compliant pictograms. Application – Critical for unmanned zones or areas with interim power reliability concerns. Feature – Rugged polycarbonate housing with gray finish and wall-mount DIN 4844 compatibility. Business Impact – Durable enclosure reduces maintenance and enables quick, standards-compliant mounting. Application – Works with standard DIN 4844 mounting rails and wall installations. Feature – Cable management via 1 x M20 plastic gland and 1 x M20 plug. Business Impact – Streamlines wiring, seals against dust and moisture, and accelerates on-site commissioning. Application – Facilitates robust installation in harsh environments while maintaining IP66 integrity.
Get a Quick Quote for a Eaton Crouse-Hinds 12191030001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds 12191030001?
Enquire Now
FAQs
Install the EXIT N sign on a wall using the DIN 4844 mounting pattern. Use the 1 x M20 plastic gland and 1 x M20 screw plug for cable entry, ensuring IP66 seals. Connect to 110-277 Vac or 110-250 Vdc power, and verify the self-contained battery is functional for outages.
The unit supports 110-277 Vac and 110-250 Vdc at 50-60 Hz. It uses LED illumination for high visibility and energy efficiency, with a self-contained battery system for outage operation.
Yes. It is IECEx/ATEX certified for Zone 1 and Zone 21, rated IP66, and designed for hazardous locations, making it appropriate for chemical plants, oil & gas sites, and mining operations requiring robust signaling.
The EXIT N sign carries IECEx/ATEX certifications, Zone 1/21 hazardous ratings, IP66 ingress protection, and CE compliance. These certifications support regulatory compliance and safe operation in hazardous environments.
The LED lamp provides long life and low energy use, while the self-contained battery reduces outage downtime and wiring needs. The rugged polycarbonate enclosure and sealed IP66 rating lower maintenance frequency, delivering a favorable total cost of ownership in harsh facilities.