Eaton Crouse-Hinds 12191030004 EXIT Sign - IP66
Part Number: 12191030004
Quick Summary
Eaton Crouse-Hinds EXIT Sign provides clear egress indication for hazardous-location facilities. In tough environments, standard signs can fail due to dust, moisture, or power outages, creating safety and compliance risks. This model is IECEx/ATEX certified for Zone 1/2 and Zone 21/22 and carries IP66 protection for washdown environments. With LED efficiency, a self-contained battery, and a wide voltage range, it reduces wiring complexity, lowers maintenance cycles, and improves uptime. For industrial plants, chemical facilities, and offshore applications, this EXIT sign supports compliant, continuous operation while aligning with asset-management and budgeting goals. It is designed for wall or ceiling installation and complements other Crouse-Hinds lighting solutions.
Product Information
Extended Description
12191030004 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EXIT Clear N exit sign, 50-60 Hz, Gray, LED, 166 lumens, Polycarbonate, Wall/ceiling mount, Self-contained battery system, 1 x M20 plastic cable glands, 1 x M20 screw plug, 110-277 Vac, 110-250 Vdc
Product Name
Eaton's Crouse-Hinds series EXIT Clear N exit sign
Catalog Number
12191030004
Product Length/Depth
380.5 mm
Product Height
175 mm
Product Width
76 mm
Product Weight
2.5 kg
EAN
4250217412783
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX
IECEx/ATEX hazardous rating
Zone 2 Zone 21 Zone 1 Zone 22
Ingress protection (IP) ratings
IP66
Lamp type
LED
Trade size
1 x M20 plastic cable glands, 1 x M20 screw plug
Special features
Self-contained battery system
Voltage rating
110-277 Vac, 110-250 Vdc
Frequency rating
50-60 Hz
Material
Polycarbonate
Housing finish color
Gray
Lumens
166
Mounting
Wall/ceiling
LED illumination delivers high visibility with low power consumption, reducing energy costs while maintaining safe egress. The result is improved emergency readiness and lower long-term operating expenses on a per-sign basis. The self-contained battery system provides independent performance during power outages, eliminating complex cabling and enabling faster, more reliable retrofits in existing facilities. A wide voltage rating of 110-277 Vac and 110-250 Vdc, supported by 50-60 Hz operation, offers flexible installation across global sites without a multi-model inventory, translating into reduced installation time and fewer stock-keeping issues. The polycarbonate housing with Gray finish and IP66 ingress protection delivers rugged durability in harsh environments, simplifying washdowns and reducing maintenance cycles. Wall/ceiling mounting and compact dimensions (380.5 mm long, 175 mm high, 76 mm wide) streamline space planning and retrofit projects, while the 2.5 kg weight aids handling and installation. Certifications for hazardous locations (IECEx/ATEX Zone 1/2 and 21/22) enable compliant deployment in chemical, petrochemical, and offshore facilities, ensuring safety-critical signage remains operational under demanding conditions. The 166 lumen LED output provides sufficient brightness for clear visibility in variable ambient lighting, supporting compliance with safety standards and reducing the risk of misinterpretation during emergencies. This sign’s design also supports routine maintenance checks and compatibility with existing Crouse-Hinds lighting ecosystems, delivering a cohesive approach to facility safety.
Get a Quick Quote for a Eaton Crouse-Hinds 12191030004
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds 12191030004?
Enquire Now
FAQs
The EXIT Clear N sign is designed for wall or ceiling mounting, offering flexible placement to suit space constraints in demanding facilities. Its dimensions (380.5 mm length, 175 mm height, 76 mm width) enable straightforward planning and retrofit without reworking adjacent fixtures. Ensure mounting surface is compatible with standard M20 glands and plugs included with the unit.
The sign operates on a broad power range of 110-277 Vac or 110-250 Vdc with a frequency of 50-60 Hz. This dual-voltage capability supports global deployment from a single SKU, reducing inventory complexity. The LED lamp produces 166 lumens, and a self-contained battery ensures operation during outages, minimizing wiring changes and improving overall reliability.
Yes. The EXIT Clear N sign carries IECEx/ATEX certification for hazardous locations, covering Zone 1/2 and Zone 21/22 classifications. It also features IP66 ingress protection, making it resistant to dust and powerful washdowns. This makes it appropriate for chemical plants, refineries, and offshore facilities where safety-critical signage must operate in harsh conditions.
The unit measures 380.5 mm in length, 175 mm in height, and 76 mm in width, with a weight of 2.5 kg. The durable polycarbonate housing is finished in Gray, and the unit includes 1 x M20 plastic cable gland and 1 x M20 screw plug. Accurate dimensions facilitate layout planning and clearance calculations for ceiling and wall-mounted configurations.
LED technology with a self-contained battery reduces ongoing maintenance by eliminating frequent lamp changes and complex wiring for outages. The IP66-rated enclosure and robust construction withstand washdowns and harsh environments, lowering downtime and replacement costs. Global voltage compatibility simplifies stocking and commissioning, supporting a faster ROI through reliable, compliant egress signaling across sites.