Eaton 12191030013 EXIT N exit sign - IECEx/ATEX Zone 21 Zone 1

Part Number: 12191030013
Manufacturer
Eaton Crouse-Hinds
Part number
12191030013

Quick Summary

EXIT N exit sign by Eaton provides reliable emergency illumination for hazardous-location applications in industrial facilities. In demanding environments, conventional signage often fails due to dust, moisture, vibration, or unexpected power loss, risking safety and compliance. This unit carries IECEx/ATEX certification for Zone 21 and Zone 1, EN 1838 visibility standards, and IP66 ingress protection, ensuring safe operation in harsh settings. Its LED efficiency, self-contained battery, and wall-mount design deliver low maintenance and fast installation, translating to reduced downtime and lower total cost of ownership. Designed for flexible power options and rugged performance, it supports retrofit and new-build projects while meeting global safety requirements.

Product Information

Extended Description

12191030013 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EXIT N exit sign, Arrow downward, Gray, LED, White letters, Polycarb, Wall mt, Cover w/ silk-screen pictogram (arrow 6h), battery, 1 x M20 plastic cable glands, 1 x M20 screw plug, EN 1838, 110-277 Vac, 110-250 Vdc
Product Name
Eaton's Crouse-Hinds series EXIT N exit sign
Catalog Number
12191030013
Product Length/Depth
380.5 mm
Product Height
175 mm
Product Width
76 mm
Product Weight
2.5 kg
EAN
4250217402135
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX
IECEx/ATEX hazardous rating
Zone 21 Zone 1
Ingress protection (IP) ratings
IP66
Lamp type
LED
Exit sign designation
Arrowhead downwards
Type
EN 1838
Trade size
1 x M20 plastic cable glands, 1 x M20 screw plug
Special features
Includes cover with silk-screen pictogram (arrow 6h), self-contained battery system
Voltage rating
110-277 Vac, 110-250 Vdc
Frequency rating
50-60 Hz
Letter color
White
Material
Polycarbonate
Housing finish color
Gray
Mounting
Wall
Feature: LED illumination with white lettering and silk-screen pictogram arrow provides high-contrast, legible signage in variable lighting. Business Impact: Lower energy use and longer LED life minimize operating costs and maintenance intervals. Application: Ideal for industrial plants where visible exit paths are critical. Feature: Self-contained battery system ensures emergency lighting remains active during mains outages. Business Impact: Maintains compliance and occupant safety, reducing downtime during grid failures. Application: Suitable for process plants and hazardous facilities with unreliable power. Feature: IP66 rated polycarbonate enclosure with wall-mount capability. Business Impact: Withstands dust, water, and impact in harsh environments, lowering replacement costs. Application: Outdoor entrances, wash-down areas, and chemical plants. Feature: EN 1838 compliant design with arrow-down signaling and silk-screen pictogram. Business Impact: Improves readability and compliance with standards for emergency signage. Application: Used in corridors and escape routes within hazardous locations. Feature: Wide voltage and versatile mounting options—110-277 Vac or 110-250 Vdc, 50-60 Hz, includes M20 glands and plug. Business Impact: Simplifies integration into retrofit projects and new builds, reducing installation time and errors. Application: Fits a broad range of facility power architectures. Feature: IECEx/ATEX certification for Zone 21 Zone 1. Business Impact: Regulatory compliance for hazardous locations minimizes risk and insurance exposure. Application: Chemical plants, oil and gas facilities, and offshore environments.

Get a Quick Quote for a Eaton Crouse-Hinds 12191030013

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds 12191030013? Enquire Now

FAQs

The EXIT N is designed for hazardous/classified locations with IECEx/ATEX Zone 21 Zone 1 certification and IP66 protection, suitable for wall-mounted installation in industrial facilities, chemical plants, and similar environments. It supports 110-277 Vac or 110-250 Vdc power and complies with EN 1838 for emergency signage visibility.
It supports a wide voltage range of 110-277 Vac or 110-250 Vdc and a frequency of 50-60 Hz, with LED illumination and white lettering for clear visibility in emergency conditions. Trade size includes 1 x M20 plastic cable glands and 1 x M20 screw plug for flexible wiring options.
Yes. The EXIT N features a self-contained battery system, providing emergency illumination during mains loss and ensuring continued visibility along exit routes without external power dependencies.
Key certifications include IECEx/ATEX for hazardous areas (Zone 21 Zone 1), EN 1838 for emergency lighting, and IP66 for ingress protection, making it suitable for demanding environments like chemical plants and offshore facilities.
Included accessories are 1 x M20 plastic cable glands and 1 x M20 screw plug, along with a cover featuring silk-screen pictogram (arrow 6h) and a self-contained battery system for straightforward, code-compliant installation on a wall.