Eaton 12191030101 EXIT N exit sign - IP66 Zone 1/21
Part Number: 12191030101
Quick Summary
EXIT N exit sign provides reliable emergency illumination for hazardous industrial spaces. In harsh facilities, ambiguous signage slows evacuations and increases risk. It carries IECEx/ATEX certifications for Zone 1/21 hazardous areas and IP66 ingress protection, ensuring performance in demanding conditions. LED efficiency, a wall-mount design, and a self-contained battery reduce maintenance while supporting global compliance and safer, faster responses in critical events.
Product Information
Extended Description
12191030101 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EXIT N exit sign, Arrowhead right, Gray, LED, White letter color, Polycarbonate, Wall mount, Cover with silk-screen pictogram (arrow 3h), battery, 2 x M20 metal thread, DIN 4844, 110-277 Vac, 110-250 Vdc
Product Name
Eaton's Crouse-Hinds series EXIT N exit sign
Catalog Number
12191030101
Product Length/Depth
380.5 mm
Product Height
175 mm
Product Width
76 mm
Product Weight
2.5 kg
EAN
4250217412776
Area classification
Hazardous/Classified Locations
Standards type
IEC IECEx/ATEX
IECEx/ATEX hazardous rating
Zone 1 Zone 21
Ingress protection (IP) ratings
IP66
Lamp type
LED
Exit sign designation
Arrowhead right
Type
DIN 4844
Trade size
2 x M20 metal thread
Special features
Includes cover with silk-screen pictogram (arrow 3h), self-contained battery system
Voltage rating
110-277 Vac, 110-250 Vdc
Frequency rating
50-60 Hz
Letter color
White
Material
Polycarbonate
Housing finish color
Gray
Mounting
Wall
Crouse-Hinds series CEAG EXIT/EXIT2 Nonmetallic LED Exit Signs catalog page
Crouse-Hinds series CEAG EXIT N Nonmetallic LED Exit Signs operating instructions
Feature → Business Impact → Application: The LED lamp delivers high-visibility illumination with low power consumption, reducing energy costs while maintaining clear exit indication in smoke and dust-prone environments; this translates to lower operating costs and improved safety margins on the shop floor and in processing plants. Feature → Business Impact → Application: A self-contained battery system provides emergency backup without external power dependencies, shortening downtime during outages and ensuring code-compliant egress lighting for all shift timetables. Feature → Business Impact → Application: The wide voltage range (110-277 Vac, 110-250 Vdc) and 50-60 Hz compatibility simplify installation across global facilities, reducing wiring complexity and stock variety while accelerating project timelines. Feature → Business Impact → Application: IP66 protection and Zone 1/21 ratings safeguard performance in wet, dusty, and explosive atmospheres, supporting compliance in chemical plants, offshore rigs, and other hazardous locations. Feature → Business Impact → Application: Wall mounting and DIN 4844 compatibility streamline retrofits and new builds, with 2 x M20 threaded entries and a silk-screen pictogram cover that enhances wiring accessibility and signage clarity. Feature → Business Impact → Application: The polycarbonate housing and gray finish deliver durable, vandal-resistant signage that withstands thermal cycling and impact, lowering replacement intervals and maintenance costs in demanding environments.
Get a Quick Quote for a Eaton Crouse-Hinds 12191030101
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds 12191030101?
Enquire Now
FAQs
Installation is designed for wall mounting with quick-access wiring. The unit features 2 x M20 metal threads for entry and a DIN 4844-compliant footprint to match standard signage infrastructure. Use the silk-screen pictogram cover to ensure clear visibility while wiring through the provided entries, and follow local hazardous-location wiring codes for a compliant, reliable deployment.
EXIT N carries IECEx/ATEX certifications suitable for Zone 1 and Zone 21 environments, along with IP66 ingress protection. These ratings confirm safe operation in hazardous locations with dust and water exposure, ensuring reliable emergency lighting in chemical plants, refineries, and similar facilities.
Yes. The unit supports a broad voltage range of 110-277 Vac and 110-250 Vdc at 50-60 Hz, enabling flexible installation across facilities with mixed power systems. The self-contained battery backup ensures illumination during power interruptions, maintaining code compliance during outages.
Absolutely. The wall-mount design, DIN 4844 compatibility, and 2 x M20 metal thread provisions simplify retrofits and new installations. The gray polycarbonate housing provides a rugged enclosure, while the silk-screen pictogram cover enhances signaling clarity for occupants during evacuations.
Investing in EXIT N reduces maintenance frequency due to its self-contained battery system and LED efficiency, lowering energy and replacement costs. Its Zone 1/21 compliance and IP66 protection minimize downtime and regulatory risk, supporting safer evacuations and faster regulatory approvals, which together translate to measurable safety and total cost of ownership improvements.