Eaton Crouse-Hinds EXIT N exit sign - IECEx/ATEX

Part Number: 12191030112
Manufacturer
Eaton Crouse-Hinds
Part number
12191030112

Quick Summary

EXIT N exit sign reliably illuminates egress paths in hazardous locations, providing clear visibility for safe evacuations in industrial facilities. In hazardous areas, teams often wrestle with signage that meets code while withstanding dust, moisture, and temperature swings. This model carries IECEx/ATEX certifications for Zone 21 and Zone 1, IP66 ingress protection, and EN 1838 lighting standards. LED efficiency, a self-contained battery, and a wall-mount design simplify installation, reduce wiring, and support faster regulatory compliance, delivering long-term lifecycle value for maintenance teams and safety managers.

Product Information

Extended Description

12191030112 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EXIT N exit sign, Arrowhead left, Gray, LED, White letter color, Polycarbonate, Wall mount, Cover with silk-screen pictogram (arrow 9h), battery, 2 x M20 metal thread, EN 1838, 110-277 Vac, 110-250 Vdc
Product Name
Eaton's Crouse-Hinds series EXIT N exit sign
Catalog Number
12191030112
Product Length/Depth
380.5 mm
Product Height
175 mm
Product Width
76 mm
Product Weight
2.5 kg
EAN
4250217408328
Area classification
Hazardous/Classified Locations
Standards type
IECEx/ATEX IEC
IECEx/ATEX hazardous rating
Zone 21 Zone 1
Ingress protection (IP) ratings
IP66
Lamp type
LED
Exit sign designation
Arrowhead left
Type
EN 1838
Trade size
2 x M20 metal thread
Special features
Includes cover with silk-screen pictogram (arrow 9h), self-contained battery system
Voltage rating
110-277 Vac, 110-250 Vdc
Frequency rating
50-60 Hz
Letter color
White
Material
Polycarbonate
Housing finish color
Gray
Mounting
Wall
The LED lamp type delivers energy-efficient illumination with extended life, minimizing replacement cycles and lowering operating costs while improving reliability in demanding environments. The self-contained battery system ensures emergency operation during power loss, reducing risk during outages and enabling compliant egress lighting without complex back-up wiring. With universal voltage input (110-277 VAC, 110-250 VDC) and 50-60 Hz compatibility, this sign can be integrated across diverse facilities, accelerating commissioning and reducing site diversity requirements. The IP66 rating and polycarbonate housing provide robust protection against dust and water ingress, extending sign life in washdown and outdoor-adjacent zones while maintaining legibility. Arrowhead left design, white lettering, and EN 1838 conformity ensure consistent visibility and regulatory alignment across shifts and sites. The wall-mount configuration plus 2 x M20 metal thread entries simplifies installation and reduces field modification time, delivering predictable project timelines and lower total cost of ownership for engineering teams. This model’s silk-screen pictogram cover (arrow 9h) supports clear wayfinding without additional custom signage costs, making it a practical choice for hazardous-location environments and regulated facilities.

Get a Quick Quote for a Eaton Crouse-Hinds 12191030112

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds 12191030112? Enquire Now

FAQs

Yes. The EXIT N sign is IECEx/ATEX certified for Zone 21 and Zone 1, with IP66 ingress protection and a rugged polycarbonate housing. It uses LED illumination and supports 110-277 VAC or 110-250 VDC power, 50-60 Hz, making it suitable for challenging industrial environments while meeting critical fire and safety regulations.
The unit is designed for wall mounting and features 2 x M20 metal thread cable entries for flexible wiring. It includes a cover with silk-screen pictogram (arrow 9h) and a self-contained battery, enabling a straightforward installation process with minimal external wiring and fast startup in new or retrofit projects.
The EXIT N sign adheres to IECEx/ATEX, EN 1838 for emergency lighting, and Zone 21/1 hazardous location classifications, with IP66 protection. These certifications ensure reliable operation in hazardous environments, compliance with international safety codes, and consistent performance across multiple jurisdictions.
Benefits include reduced maintenance due to LED longevity and a self-contained battery that minimizes external power dependencies. The durable IP66-rated housing lowers replacement costs in washdown areas, while universal voltage compatibility simplifies sourcing and reduces install time, delivering a faster payback in facilities with strict uptime and safety requirements.
This model excels in chemical plants, oil and gas facilities, mining sites, and offshore platforms where Zone 21/1 hazards and harsh environmental conditions prevail. Its rugged construction, EN 1838 compliance, and robust visibility support reliable egress signaling in high-risk industrial applications.