Eaton 12193020121 EXIT Sign - IP66 ISO 7010
Part Number: 12193020121
Quick Summary
The Eaton 12193020121 EXIT Sign is a robust LED exit indicator designed for safe egress in challenging industrial environments. In harsh plants where moisture, dust, and vibration threaten visibility, conventional signs often fail to provide reliable signaling—leading to compliance risk and delayed evacuations. This unit carries IEC standards with IP66 protection and hazardous-location ratings (IECEx/ATEX Zone 2 and Zone 22), ensuring safety signage remains functional where it matters most. With ISO 7010 pictograms, a gray polycarbonate housing, and wall-mount compatibility, it delivers durable visibility while minimizing maintenance costs. For engineers and procurement teams, this sign combines compliance, performance, and long-term value in a single, easy-to-specify package.
Product Information
Extended Description
12193020121 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EXIT 2 V-CG-S exit sign, Arrowhead right, Gray, LED, White letters, Polycarbonate, Wall mount, Cover w/ pictogram (arrow 3h), monitoring, 2 x M20 metal thread, ISO 7010, 220-254 Vac, 195-250 Vdc
Product Name
Eaton's Crouse-Hinds series EXIT 2 V-CG-S exit sign
Catalog Number
12193020121
Product Length/Depth
380.5 mm
Product Height
175 mm
Product Width
76 mm
Product Weight
2.2 kg
EAN
4250959910998
Area classification
Hazardous/Classified Locations
Standards type
IEC
IECEx/ATEX hazardous rating
Zone 2 Zone 22
Ingress protection (IP) ratings
IP66
Lamp type
LED
Exit sign designation
Arrowhead right
Type
ISO 7010
Trade size
2 x M20 metal thread
Special features
Includes cover with silk-screen pictogram (arrow 3h), monitoring module
Voltage rating
220-254 Vac, 195-250 Vdc
Frequency rating
50-60 Hz
Letter color
White
Material
Polycarbonate
Housing finish color
Gray
Mounting
Wall
Feature: LED lamp technology provides high visibility with long life and low power consumption → Business Impact: Reduces maintenance frequency and energy costs while ensuring constant egress illumination; Application: Ideal for continuous-duty exit signaling in production lines and warehouses. Feature: ISO 7010 arrowhead right designation → Business Impact: Standardized wayfinding that accelerates occupant evacuation and meets global safety communication norms; Application: Plant corridors and control room areas requiring clear directional signage. Feature: IP66 enclosure rating → Business Impact: Superior dust and water ingress protection, extending signage life in harsh environments; Application: Wet, dusty, or chemically aggressive locations such as rinsing bays and spray areas. Feature: Hazardous-location ratings Zone 2/ Zone 22 (IECEx/ATEX) → Business Impact: Ensures regulatory compliance across sites handling flammable liquids or dust; Application: Chemical plants, refineries, and offshore facilities. Feature: Wall-mount with polycarbonate gray housing and 2 x M20 threads → Business Impact: Simple, versatile installation with a robust enclosure; Application: Retrofit or new installations where space and mounting options are constrained. Feature: Monitoring module and cover with pictogram (arrow 3h) → Business Impact: Proactive fault indication and certified signage clarity, reducing unscheduled repairs; Application: Facilities management programs that demand traceable maintenance. Feature: 220-254 Vac / 50-60 Hz (DC compatibility 195-250 Vdc) → Business Impact: Flexible power sourcing to match site infrastructure; Application: Controls-driven environments with dual-voltage requirements. The combination of these features supports measurable outcomes such as reduced downtime, improved regulatory alignment, and lower total cost of ownership across hazardous-location installations.
Get a Quick Quote for a Eaton Crouse-Hinds 12193020121
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds 12193020121?
Enquire Now
FAQs
Install on a secure wall using the two M20 metal-thread mounting points, ensuring the IP66-rated seals are tightened to prevent ingress. Connect the unit to a 220-254 Vac supply, observing the 50-60 Hz rating and, if needed, the 195-250 Vdc compatibility. Verify the cover with silk-screen pictogram is in place to display the ISO 7010 arrowhead right symbol, and ensure the monitoring module is correctly seated for status reporting.
The unit carries IECEx/ATEX hazardous-location ratings for Zone 2 and Zone 22, along with an IP66 ingress protection rating. It complies with IEC standards and uses ISO 7010 pictograms, delivering reliable signage in explosive or dust-laden environments while meeting global safety requirements.
Yes. The EXIT Sign is specified with an Arrowhead right designation and includes a cover featuring silk-screen pictograms aligned to ISO 7010, with white lettering on a gray polycarbonate housing for high-contrast visibility in industrial settings.
The sign operates at 220-254 Vac with a 50-60 Hz frequency rating. It also supports a DC range of 195-250 Vdc, enabling compatibility with facilities that use dual-voltage power feeds and providing flexibility across different plant electrical systems.
The built-in monitoring module provides status indication and fault reporting, enabling proactive maintenance and reducing unscheduled outages. When paired with a preventative-maintenance program, it lowers downtime costs, extends LED life, and supports compliance records for hazardous-location installations.