Eaton Crouse-Hinds 841B-480 Receptacle - IP66-rated
Part Number: 841B-480
Quick Summary
The 841B-480 receptacle provides 480 VAC, 20 A three-wire power delivery for industrial equipment. In harsh plant environments, moisture ingress and corrosion drive unplanned downtime. It carries IP66 ingress protection and is suitable for Ordinary/Non-Hazardous locations, supporting reliable operation in demanding settings. Designed for Pauluhn 800 interlock configurations, this brass-bodied unit offers durable, maintenance-friendly installation that reduces lifecycle costs and improves uptime.
Product Information
Extended Description
841B-480 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Pauluhn 800 receptacle, 20A, Three-wire, two-pole, Brass, 480 Vac
Product Name
Eaton Crouse-Hinds series Pauluhn 800 receptacle
Catalog Number
841B-480
Product Length/Depth
5.19 in
Product Height
7.5 in
Product Width
4.5 in
Product Weight
7.5 lb
UPC
662276387522
Area classification
Ordinary/Non-Hazardous Locations
Ingress protection (IP) ratings
IP66
Amperage Rating
20A
Voltage rating
480 Vac
Material
Brass
Pauluhn Marine Interlock Receptacles catalog page
IF LBL 1545 - 841B, 842B, 843B, 844B Interlocking Switches and Receptacles
Eaton Specification Sheet - 841B-480
Feature → Business Impact → Application: The 841B-480 is rated for 20 A at 480 VAC, enabling reliable power delivery to standard industrial equipment while keeping circuit protection aligned with common motor loads and control circuits, reducing nuisance trips and energy waste. This translates to measurable uptime improvements and lower maintenance costs in manufacturing lines and process facilities. Application: Ideal for Pauluhn 800 interlock setups in conveyors, pumps, and processing equipment where dependable interlock operation is critical. Feature → Business Impact → Application: Brass construction delivers robust corrosion resistance in aggressive environments, extending the service life of receptacles in outdoor, marine, and washdown areas. This lowers replacement frequency and simplifies inventory management for spare parts. Application: Suitable for harsh plant corners, loading bays, and exposed plant floor spaces where durability matters. Feature → Business Impact → Application: IP66 ingress protection protects against dust and powerful water jets, reducing ingress-related failures and maintenance downtime. This protection is essential for equipment located near washdowns, splash zones, or outdoor installations. Application: Outdoor process areas and non-hazardous locations requiring rugged, sealed connectivity. Feature → Business Impact → Application: Three-wire, two-pole configuration supports straightforward wiring and safer interlock integration with 800-series switches. This simplifies installation procedures and improves electrical safety in control panels and remote stations. Application: Control panel assemblies and remote receptacle locations across manufacturing lines. Feature → Business Impact → Application: Pauluhn 800 interlock compatibility ensures standardized interlock operation with Eaton Crouse-Hinds interlocks, reducing spare-part complexity and enabling faster field servicing. Application: Systems engineering for modular interlock solutions in industrial plants. Feature → Business Impact → Application: Clear dimensions and weight (5.19 in depth, 7.5 in height, 4.5 in width, 7.5 lb) support precise enclosure planning and faster retrofit projects. Application: Facility upgrades and equipment retrofits where space and weight budgets are constrained.
Get a Quick Quote for a Eaton Crouse-Hinds 841B-480
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds 841B-480?
Enquire Now
FAQs
The 841B-480 is designed for Pauluhn 800 interlock configurations and supports standard 3-wire, 2-pole wiring. Its dimensions (5.19 in depth, 7.5 in height, 4.5 in width) and brass construction enable straightforward mounting to common enclosure footprints, with mounting patterns compatible with Eaton Crouse-Hinds interlock assemblies. For retrofit projects, verify clearance around the receptacle and ensure the interlock mechanism aligns with existing 800-series components to avoid misalignment or latch interference.
Key specs include a 20A amperage rating and a 480 VAC voltage rating, suitable for typical industrial motors and control circuits. The IP66 ingress protection reduces dust and water exposure, supporting reliable operation in wet or dusty environments. The three-wire, two-pole configuration simplifies wiring, and brass construction provides durability under frequent plug-in/out cycles common in maintenance operations.
The unit is ideal for manufacturing, process automation, and material handling where Pauluhn 800 interlocks are part of the system. It is rated for Ordinary/Non-Hazardous Locations and carries IP66 protection, making it suitable for outdoor installations, wash-down areas, and other environments where moisture and dust exposure are concerns.
The receptacle is rated for Ordinary/Non-Hazardous Locations and features IP66 ingress protection, aligning with common industrial safety and installation standards. While CE or other region-specific certifications are not listed in the provided data, the IP66 rating and Pauluhn 800 interlock compatibility address essential compliance needs for rugged, non-hazardous industrial environments.
Durable brass construction and IP66 protection minimize ingress-related maintenance and part replacement, contributing to longer service life and lower lifecycle costs. The receptacle’s compatibility with Pauluhn 800 interlocks simplifies wiring and reduces field service time, supporting faster repairs and reduced downtime. In retrofit or new-install projects, these factors collectively improve asset availability and return on investment.