PowerGard Receptacle Assembly – CFS250-1523-M15 (Hazardous)

Part Number: CFS250-1523-M15
Manufacturer
Eaton Crouse-Hinds
Part number
CFS250-1523-M15

Quick Summary

PowerGard Receptacle Assembly is a rugged, code-compliant outlet solution for hazardous-area electrical enclosures and back boxes. Procurement teams often wrestle with safety certifications, installation compatibility, and long lead times in harsh environments. This model carries NEC/CEC compliance with hazardous ratings Class I, Division 1; Class II, Division 1; and Class III, plus a NEMA 3/3R protection profile to ensure safe operation in demanding settings. In addition, its copper-free aluminum body and 1/2" trade size support durable, installation-friendly performance in industrial power distribution, while two-gang, dead-end configuration simplifies wiring and reduces footprint in tight spaces.

Product Information

Extended Description

CFS250-1523-M15 Eaton Crouse-Hinds: Eaton Crouse-Hinds series PowerGard receptacle assembly, 15A, Two-wire, three-pole, Copper-free aluminum, Two-gang, Dead end, 1/2", M15 model, 125 Vac
Product Name
Eaton Crouse-Hinds series PowerGard receptacle assembly
Catalog Number
CFS250-1523-M15
Product Length/Depth
7 in
Product Height
10 in
Product Width
7 in
Product Weight
6.44 lb
UPC
662276516892
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
3 3R
Number of gangs
Two-gang
Style
Dead end
Configuration
Two-wire, three-pole
Trade size
1/2"
Amperage Rating
15A
Voltage rating
125 Vac
Material
Copper-free aluminum
Type
M15 model
Feature → Business Impact → Application: The two-gang, dead-end configuration supports a 1/2" trade size, enabling compact installation in confined enclosures and reducing enclosure depth and mounting complexity across power distribution panels. This translates to faster wiring, easier dust- and moisture-sealed installations, and lower labor costs in large-scale builds. Application: suitable for PowerGard back boxes in hazardous locations where space is at a premium and high reliability is required. Feature → Business Impact → Application: Copper-free aluminum construction offers excellent corrosion resistance while keeping weight down, improving handling during field installation and reducing maintenance costs over the product life cycle. Application: oil and gas, chemical processing, and mining sites with aggressive atmospheres. Feature → Business Impact → Application: 15A at 125 Vac two-wire, three-pole configuration provides standard wiring geometry and predictable breaker coordination, accelerating panel integration and minimizing miswiring risks. Application: industrial controls and distributed power systems. Feature → Business Impact → Application: Dead-end, two-gang housing supports robust mounting against vibration and plug interfaces while maintaining enclosure integrity. Application: hazardous-area receptacle installations requiring dependable mechanical stability. Feature → Business Impact → Application: NEC/CEC compliance with Class I, Division 1 (and related classifications) reduces regulatory risk and accelerates project approval. Application: any installation requiring proven hazardous-location certification.

Get a Quick Quote for a Eaton Crouse-Hinds CFS250-1523-M15

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds CFS250-1523-M15? Enquire Now

FAQs

The CFS250-1523-M15 is designed as a two-gang, dead-end receptacle with a 1/2 inch trade size and copper-free aluminum housing. When installing in hazardous locations, ensure NEC Class I Division 1 compliance, proper sealing for the enclosure, and compatibility with PowerGard back boxes and ECP plugs. Use the official IF 1663 instruction sheet for step-by-step guidance.
This receptacle assembly is rated for 15A and 125 Vac, configured as two-wire, three-pole. The compact 7 in by 7 in footprint (two-gang) supports straightforward wiring and terminations, aiding fast commissioning in control panels and field installations while maintaining standard industry wiring practices.
Yes. The PowerGard series is intended for hazardous/classified locations with Class I, Division 1 ratings and NEMA 3/3R protection, making it appropriate for oil & gas, mining, and chemical processing areas where corrosive exposure and stringent safety standards are common.
Expect NEC/CEC compliance with hazardous-area ratings Class I, Division 1, Class II, Division 1, and Class III, as well as NEMA 3/3R protection. UL certification references are available in the provided catalog pages and installation literature to support your compliance dossiers.
Copper-free aluminum reduces weight and corrosion risk, lowering handling and maintenance costs in harsh environments. The robust two-gang, dead-end design simplifies installation and reduces field troubleshooting time, contributing to faster project completion and lower lifecycle costs in hazardous-location power distribution.