Eaton Crouse-Hinds CFS275-20232-M15 PowerGard Receptacle Assembly - Hazardous

Part Number: CFS275-20232-M15
Manufacturer
Eaton Crouse-Hinds
Part number
CFS275-20232-M15

Quick Summary

PowerGard receptacle assembly provides hazardous-location power distribution for industrial facilities with demanding safety requirements. Engineers often wrestle with complex wiring, strict regulatory compliance, and long commissioning times in classified locations. This unit carries NEC/CEC compliance with Class I, Division 1 and NEMA 3/3R ratings, delivering reliable performance in harsh environments. The copper-free aluminum construction and clear labeling simplify installation, maintenance, and inspection workflows. By integrating robust protection with proven reliability, it helps reduce downtime, improve safety, and lower total cost of ownership while supporting standard two-gang installations and 20A, 250 VAC service.

Product Information

Extended Description

CFS275-20232-M15 Eaton Crouse-Hinds: Eaton Crouse-Hinds series PowerGard receptacle assembly, 20A, Two-wire, three-pole, Copper-free aluminum, Two-gang, Dead end, 3/4", M15 model, 250 Vac
Product Name
Eaton Crouse-Hinds series PowerGard receptacle assembly
Catalog Number
CFS275-20232-M15
Product Length/Depth
7 in
Product Height
10 in
Product Width
7 in
Product Weight
6.44 lb
UPC
662276517639
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
3 3R
Number of gangs
Two-gang
Style
Dead end
Configuration
Two-wire, three-pole
Trade size
3/4"
Amperage Rating
20A
Voltage rating
250 V AC
Material
Copper-free aluminum
Type
M15 model
Feature → Business Impact → Application: Two-wire, three-pole configuration supports straightforward wiring in hazardous locations, enabling safer and faster installation in classified areas or outdoor facilities. This translates to reduced on-site labor time and improved first-pass compliance during commissioning. Feature → Business Impact → Application: Copper-free aluminum construction offers corrosion resistance and lighter weight compared with traditional materials, enhancing durability in harsh environments and lowering handling costs during maintenance and replacement. Feature → Business Impact → Application: Two-gang, dead-end configuration with a 3/4" trade size matches common enclosure footprints, ensuring seamless fitment in existing panels and reducing the need for custom fabrication. Feature → Business Impact → Application: NEC/CEC standards alignment, Class I, Division 1; Class II/III, plus NEMA 3 and 3R ratings provide confidence for industrial plants, refineries, and offshore/offsite facilities seeking regulatory compliance and safer asset management. Feature → Business Impact → Application: 20A, 250 VAC rating enables reliable power delivery for medium-duty equipment, supporting energy efficiency initiatives and predictable startup sequences in critical processes. Feature → Business Impact → Application: Documentation such as IF 1663 installation sheets and the Eaton specification sheet streamline training and vendor audits, lowering risk of wiring errors and speeding supplier qualification. The cumulative effect is safer installations, faster maintenance, lower replacement costs, and improved uptime across hazardous-location applications.

Get a Quick Quote for a Eaton Crouse-Hinds CFS275-20232-M15

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds CFS275-20232-M15? Enquire Now

FAQs

The CFS275-20232-M15 is designed for Hazardous/Classified Locations with NEC Class I, Division 1, Class II, Division 1, and Class III ratings. It uses a two-wire, three-pole configuration in a two-gang, dead-end setup with a 3/4 inch trade size, making it suitable for compliant installations in Class I/II/III environments.
It is rated for 20A at 250 VAC, made from copper-free aluminum, and configured for two-wire, three-pole connections. The unit supports a two-gang, dead-end installation with a 3/4 inch trade size, accommodating standard industrial wiring practices.
The receptacle complies with NEC/CEC standards, including NEC hazardous-location ratings Class I Division 1, Class II Division 1, and Class III, along with NEMA 3 and 3R ratings. It is suitable for Hazardous/Classified Locations and supports safe operation in harsh environments.
The dead-end, two-wire three-pole configuration, combined with copper-free aluminum construction, simplifies mounting and wiring while offering corrosion resistance. This reduces commissioning time, lowers maintenance frequency, and enhances long-term reliability in challenging environments.
By delivering robust corrosion resistance, compliant safety ratings, and faster installation, the PowerGard receptacle reduces downtime, lowers rework costs, and shortens maintenance cycles. The return comes from improved uptime, easier audits, and lower total cost of ownership over the asset life.