Eaton CFSC175-2023-M15 PowerGard Receptacle - Class I/II/III

Part Number: CFSC175-2023-M15
Manufacturer
Eaton Crouse-Hinds
Part number
CFSC175-2023-M15

Quick Summary

PowerGard receptacle assembly enables safe, reliable 125 VAC through-feed connections in hazardous locations. In industrial wiring, downtime, noncompliance, and difficult installs in harsh environments are persistent pain points. This unit delivers NEC/CEC compliance and hazardous-location ratings for Class I Division 1, Class II Division 1, and Class III, along with a rugged NEMA 3 or 3R enclosure. Copper-free aluminum construction reduces weight and corrosion risk, while the through-feed, single-gang form factor streamlines field wiring and future upgrades. Designed for through-feed receptacles in oil, gas, chemical processing, and heavy manufacturing, it supports safe, code-compliant power distribution with lower maintenance costs.

Product Information

Extended Description

CFSC175-2023-M15 Eaton Crouse-Hinds: Eaton Crouse-Hinds series PowerGard receptacle assembly, 20A, Two-wire, three-pole, Copper-free aluminum, Single-gang, 2015 edition, Through feed, 3/4", 125 Vac
Product Name
Eaton Crouse-Hinds series PowerGard receptacle assembly
Catalog Number
CFSC175-2023-M15
Product Length/Depth
3.24 in
Product Height
6.48 in
Product Width
5.87 in
Product Weight
3.8 lb
UPC
662276515833
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
3 3R
Number of gangs
Single-gang
Style
Through feed
Configuration
Two-wire, three-pole
Trade size
3/4"
Amperage Rating
20A
Voltage rating
125 Vac
Material
Copper-free aluminum
Special features
2015 edition
Feature → Business Impact → Application: Amperage, voltage, and configuration set at 20A, 125 Vac in a two-wire, three-pole setup to meet common industrial loads while preserving headroom for startup surges. This translates to safer circuits, reduced nuisance tripping, and predictable maintenance windows in control panels used in hazardous environments. Application: power distribution in chemical plants and refineries where reliable control power is essential. Feature → Business Impact → Application: Copper-free aluminum housing delivers corrosion resistance and lighter weight, cutting installation fatigue and long-term enclosure maintenance costs. Application: outdoor and indoor hazardous-area installations where moisture and chemical exposure are prevalent. Feature → Business Impact → Application: Through-feed, 3/4" trade size with single-gang configuration simplifies wiring runs, minimizes junction boxes, and accelerates field deployment. Application: new builds and retrofit projects requiring clean, scalable through-feed connections. Feature → Business Impact → Application: Hazardous/Classified Locations area classification and NEC/CEC standards alignment ensure regulatory compliance and safer operations. Application: oil & gas facilities, chemical processing plants, and heavy manufacturing. Feature → Business Impact → Application: NEMA 3 and 3R protection enhances environmental resilience against rain, dust, and temperature swings. Application: outdoor enclosures and exposed industrial environments. Feature → Business Impact → Application: 2015 edition features align with current industry expectations, reducing obsolescence risk and ensuring compatibility with latest Eaton PowerGard accessories. Application: long-term capital projects and ongoing maintenance programs in hazardous-lacations ecosystems.

Get a Quick Quote for a Eaton Crouse-Hinds CFSC175-2023-M15

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds CFSC175-2023-M15? Enquire Now

FAQs

CFSC175-2023-M15 is designed for through-feed, single-gang installations in hazardous/classified locations. It meets NEC/CEC standards and carries Class I Division 1, Class II Division 1, and Class III ratings, making it suitable for oil, gas, chemical processing, and other demanding industrial settings.
The receptacle is rated for 20A at 125 VAC, configured as two-wire, three-pole, with a 3/4 inch trade size. This supports common industrial loads while maintaining safety and regulatory compliance in hazardous environments.
Yes. The unit is rated for NEMA 3 and 3R protection, providing robust enclosure performance against dust, rain, and environmental exposure in harsh industrial locations.
It aligns with NEC/CEC standards, includes NEC hazardous ratings for Class I, II, and III, and offers NEMA 3/3R protection. Canadian certifications and UL-listed documents are available in product literature and UL pages linked in the downloads section.
Through-feed with a 3/4" trade size and single-gang footprint reduces wiring complexity, minimizes enclosure count, and speeds field deployment while maintaining code compliance and reliable system integrity in hazardous locations.