Eaton CFSC250-1523-M15 PowerGard Receptacle - Hazardous

Part Number: CFSC250-1523-M15
Manufacturer
Eaton Crouse-Hinds
Part number
CFSC250-1523-M15

Quick Summary

PowerGard receptacle assembly from Eaton Crouse-Hinds delivers reliable, hazardous-location power distribution for industrial facilities. The CFSC250-1523-M15 model provides 15A at 125V in a two-gang, through-feed configuration to simplify wiring access and reduce panel footprint. Operators frequently contend with corrosive environments, limited space, and strict compliance demands; this design mitigates downtime with copper-free aluminum construction and a robust mounting scheme. Key certifications include NEC/CEC alignment and NEMA 3/3R protection for dependable operation in hazardous locations. By combining durable materials with certified safety, this solution supports maintenance efficiencies and long-term cost predictability while integrating smoothly with PowerGard accessories and standard electrical boxes.

Product Information

Extended Description

CFSC250-1523-M15 Eaton Crouse-Hinds: Eaton Crouse-Hinds series PowerGard receptacle assembly, 15A, Two-wire, three-pole, Copper-free aluminum, Two-gang, Through feed, 1/2", M15 model, 125 Vac
Product Name
Eaton Crouse-Hinds series PowerGard receptacle assembly
Catalog Number
CFSC250-1523-M15
Product Length/Depth
7 in
Product Height
10 in
Product Width
7 in
Product Weight
6.44 lb
UPC
662276516915
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
3 3R
Number of gangs
Two-gang
Style
Through feed
Configuration
Two-wire, three-pole
Trade size
1/2"
Amperage Rating
15A
Voltage rating
125 Vac
Material
Copper-free aluminum
Type
M15 model
Feature → Business Impact → Application: Two-wire, three-pole configuration in a two-gang, through-feed receptacle enables straightforward wiring and faster installation, reducing commissioning time and minimizing field errors in complex panels. This improves overall uptime and lowers labor costs in batch and continuous-process environments. Application: Through-feed design is ideal for equipment clusters in chemical plants or oil & gas facilities, where secure wiring and reliable feed-through are critical. Feature → Business Impact → Application: Copper-free aluminum construction provides excellent corrosion resistance in damp or chemically aggressive environments, extending service life and reducing maintenance cycles. Application: Suitable for outdoor-rated or enclosure-attached installations in hazardous locations, minimizing replacement intervals. Feature → Business Impact → Application: 15A, 125Vac rating supports common control circuits and lighting in hazardous areas, enabling compliant integration with standard industrial power distribution. Application: OEM panels and service panels in Class I, Division 1/2 environments benefit from NEC/CEC compliance and easy integration with PowerGard components. Feature → Business Impact → Application: NEMA 3 and 3R ratings offer reliable enclosure protection, improving safety margins in wet or dusty facilities. Application: Critical for facilities operating under stringent regulatory regimes and needing proven protection during maintenance outages. Feature → Business Impact → Application: M15 model and two-gang footprint fit typical 1/2 inch trade size back boxes, simplifying retrofits and new installations alike. Application: Retrofit projects in aging plants where space and standardization drive faster upgrades.

Get a Quick Quote for a Eaton Crouse-Hinds CFSC250-1523-M15

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds CFSC250-1523-M15? Enquire Now

FAQs

Install in a two-gang, through-feed back box using 1/2 inch trade size openings. Secure the copper-free aluminum body, connect two-wire, three-pole conductors, and follow NEC/CEC guidelines for Class I, Division 1 installations. Use manufacturer installation sheets IF 1663 as reference for wiring diagrams and torque specs.
The unit is 15A at 125Vac with a two-wire, three-pole configuration. It is designed for 1/2 inch trade size through-feed boxes and two-gang assemblies, compatible with standard PowerGard accessories and common electrical back boxes used in hazardous locations.
Yes, it is rated for Hazardous/Classified Locations with NEC/CEC compliance. Specific NEC hazardous ratings include Class I, Division 1, Class II, Division 1, and Class III, with NEMA ratings 3 and 3R for enclosure protection.
Copper-free aluminum resists corrosion in harsh environments, extending service intervals. Regular visual inspections, clean connections, and verification of mounting hardware and seals are recommended. UL and NEC/CEC certifications support ongoing compliance and predictable lifecycle costs.
The two-gang, through-feed design streamlines wiring, reduces installation time, and minimizes field faults in hazardous areas. With certified protection (NEMA 3/3R, NEC/CEC), installers avoid retrofit penalties, improving uptime and lowering maintenance labor, yielding faster ROIs on modernization projects.