Eaton CFSC275-1523 PowerGard Receptacle - Hazardous
Part Number: CFSC275-1523
Quick Summary
PowerGard receptacle CFSC275-1523 by Eaton Crouse-Hinds provides reliable hazardous-location connections for industrial equipment. In harsh environments, miswiring, corrosion, and certification gaps drive maintenance costs and safety risk. This unit meets NEC/CEC standards and is rated for Class I, Division 1; Class II, Division 1; and Class III, with NEMA 3 and 3R ratings for rugged indoor/outdoor service. Designed for through-feed, two-gang installations at 3/4 inch trade size, it supports copper-free aluminum and 125 VAC operation, simplifying procurement and speeding installation while reducing downtime and total cost of ownership. Businesses gain predictable performance, improved safety, and a clear path to compliance across facilities with demanding hazardous locations.
Product Information
Extended Description
CFSC275-1523 Eaton Crouse-Hinds: Eaton Crouse-Hinds series PowerGard receptacle assembly, 15A, Two-wire, three-pole, Copper-free aluminum, Two-gang, Through feed, 3/4", 125 Vac
Product Name
Eaton Crouse-Hinds series PowerGard receptacle assembly
Catalog Number
CFSC275-1523
Product Length/Depth
7 in
Product Height
10 in
Product Width
7 in
Product Weight
6.44 lb
UPC
662276361331
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
3 3R
Number of gangs
Two-gang
Style
Through feed
Configuration
Two-wire, three-pole
Trade size
3/4"
Amperage Rating
15A
Voltage rating
125 Vac
Material
Copper-free aluminum
PowerGard Explosionproof NEMA Locking Receptacles brochure
PowerGard Explosionproof NEMA Locking Receptacles catalog page
PowerGard Explosionproof NEMA Locking Receptacles Canadian certification (Receptacles with Plugs Interlocked with Switches)
PowerGard Explosionproof NEMA Locking Receptacles Canadian certification (Receptacles with Plugs Interlocked with Switches)
PowerGard Explosionproof NEMA Locking Receptacles Canadian certification (Receptacles with Plugs Interlocked with Switches)
PowerGard Explosionproof NEMA Locking Receptacles Canadian certification (Receptacles with Plugs Interlocked with Switches)
IF 1663 - PowerGard Receptacles
Eaton Specification Sheet - CFSC275-1523
Hazardous location certification and NEMA ratings are built into the CFSC275-1523, ensuring regulatory compliance and enhanced worker safety in demanding environments. The business impact is a reduction in commissioning lead times and a lower risk of non-compliance penalties, making this receptacle ideal for chemical plants, refineries, and mining sites that require robust protection and reliable performance. Application-wise, the two-wire, three-pole configuration supports standard equipment without custom wiring, enabling faster panel integration and easier spare-part planning. Copper-free aluminum reduces weight and improves corrosion resistance, lowering long-term maintenance costs and mitigating environmental exposure in outdoor or damp locations. With 7 in length and 10 in height in a two-gang, through-feed form factor, installation fits compact spaces while delivering durable, explosion-protected connectivity. This design also improves thermal performance and minimizes enclosure footprint in crowded control panels. Long-term reliability is reinforced by NEC/CEC compliance, NEMA 3 and 3R protection, and access to Eaton documentation such as IF 1663 and the CFSC275-1523 specification sheet, which supports installation accuracy and proactive maintenance planning. Overall, this receptacle aligns with industry best practices for hazardous-location electrical connectors, offering a practical path to safer, compliant operations.
Get a Quick Quote for a Eaton Crouse-Hinds CFSC275-1523
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds CFSC275-1523?
Enquire Now
FAQs
The CFSC275-1523 uses a through-feed, two-wire, three-pole configuration designed for hazardous classifications. Refer to the IF 1663 PowerGard installation sheet and the Eaton specification page CFSC275-1523 for wiring diagrams, mounting guidance, and safety notes to ensure NEC/CEC compliance.
Yes. The receptacle assembly is specified for NEC/CEC compliance with NEC hazardous ratings including Class I, Division 1, Class II, Division 1, and Class III, plus NEMA 3 and 3R protection, suitable for hazardous/classified locations.
The unit is a two-gang through-feed receptacle with approximate dimensions of 7 inches in length and width, 10 inches in height, and a weight of about 6.44 pounds, making it suitable for compact industrial panels.
Ideal for chemical plants, oil and gas facilities, and other hazardous environments requiring explosion-proof connectivity, the two-wire, three-pole configuration supports 15A at 125 VAC in copper-free aluminum for durable service.
Key distinctions include area classification for Hazardous/Classified Locations, NEC/CEC standards, NEMA ratings of 3 and 3R, and the copper-free aluminum construction, all contributing to safety, durability, and regulatory compliance.