Eaton Crouse-Hinds CGB395 Cable Gland - NEC/CEC
Part Number: CGB395
Quick Summary
The CGB395 cable gland from Eaton Crouse-Hinds provides a reliable seal for tray cables in general-purpose electrical enclosures. Unsealed gland entries can invite moisture ingress, cable movement, and unplanned downtime in harsh industrial environments. This model supports NEC/CEC standards, a NEMA rating of 3R and 4, and is suitable for ordinary/non-hazardous locations, underscoring its suitability for everyday plant applications. It is designed for non-armoured tray cables with a 0.500–0.625 inch range and a 1 inch NPT thread, offering straightforward installation and dependable field performance. Compatible with Eaton’s installation guides and catalogs, the CGB395 helps maintain compliance while reducing maintenance frequency and lifecycle costs.
Product Information
Extended Description
CGB395 Eaton Crouse-Hinds: Eaton Crouse-Hinds series CGB cable gland, Cable range min/max: 0.500-0.625", Non-armoured and tray cable, Non-armoured, Steel, General purpose, 1" NPT
Product Name
Eaton Crouse-Hinds series CGB cable gland
Catalog Number
CGB395
Product Length/Depth
2.38 in
Product Height
1.66 in
Product Width
1.66 in
Product Weight
0.59 lb
UPC
782274134000
Area classification
Ordinary/Non-Hazardous Locations
Standards type
NEC/CEC
NEMA Rating
3R 4
Protection type
General purpose
Cable type
Tray cable Non-armoured
Gland type
Non-armoured
Thread Size
1"
Thread type
NPT
Cable range (min/max)
0.500-0.625"
Material
Steel
Crouse-Hinds series Tray Cable Glands brochure
Crouse-Hinds series CGB, CGD, CGE and CGFP Non-armoured Glands catalog page
CGB, CGD, CGE and CGFP Non-armoured Glands UL certification
CGB, CGD, CGE and CGFP Non-armoured Glands UL certification
IF 1826 - CGB, CGD and CGE Connectors
IF 1826 - CGB, CGD and CGE Connectors
Eaton Specification Sheet - CGB395
Feature: 0.500-0.625 inch cable range and 1 inch NPT thread. Business impact: Accommodates standard tray cables without oversizing, enabling faster installs and reduced component variance in panels. Application: Ideal for control cabinets and junction boxes handling non-armoured tray cables in general purpose facilities. Feature: Steel construction. Business impact: Delivers robust mechanical protection in ordinary locations, improving durability and long-term reliability even in busy production floors. Application: Suitable for damp or moderate environments where metal glands are preferred for integrity. Feature: Non-armoured gland for tray cables. Business impact: Simplifies sourcing and inventory while minimizing space and weight, lowering total installed cost. Application: Works well in compact enclosures with limited entry clearance. Feature: NEMA 3R/4 protection and NEC/CEC compliance. Business impact: Supports regulatory compliance and safer operation, reducing risk of ingress and associated maintenance. Application: Widely applicable to non-hazardous areas in industrial plants. Feature: Compact dimensions (2.38 in length, 1.66 in width, 1.66 in height) and 0.59 lb weight. Business impact: Eases handling, transport, and installation in crowded electrical rooms, improving site efficiency. Application: Benefits installers and maintenance teams during retrofits or new builds. Feature: Documentation and compatibility resources. Business impact: Access to IF 1826 installation sheets and catalog pages accelerates correct mounting and reduces commissioning time. Application: Field technicians rely on official guides for consistent gland performance.
Get a Quick Quote for a Eaton Crouse-Hinds CGB395
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds CGB395?
Enquire Now
FAQs
The CGB395 is designed for non-armoured tray cables with a 0.500–0.625 inch range and uses a 1 inch NPT thread. It fits standard tray cable gland entries in general-purpose enclosures. For armoured cables or alternative ranges, refer to the Crouse-Hinds catalog pages and specific gland variants to ensure proper fit and seal integrity.
CGB395 carries NEC/CEC standard compliance and a NEMA rating of 3R/4, suitable for ordinary/non-hazardous locations. This combination provides reliable ingress protection and consistent sealing in typical plant environments, reducing maintenance calls related to moisture or dust intrusion while supporting code compliance.
Yes. The gland is crafted for non-armoured tray cables in general-purpose electrical installations, making it well suited for control panels, junction boxes, and other enclosure entries where a robust, straightforward seal is required without armour protection. Always pair with the correct gland size for your cable and enclosure depth.
The CGB395 aligns with NEC/CEC standards and is intended for ordinary locations with NEMA 3R/4 protection. UL certification sheets are available in Eaton’s documentation bundles, and the IF 1826 installation instruction sheets provide validated mounting procedures to ensure compliant installations.
The gland’s non-armoured, 1" NPT design and compact dimensions simplify installation in crowded spaces, reducing installation time and enabling quicker retrofits. Durable steel construction lowers maintenance needs, while NEC/CEC compliance helps avoid non-compliance penalties, contributing to a lower total cost of ownership over the product lifecycle.