Eaton Crouse-Hinds CGBS4018 Cord Connector - Explosion-Proof

Part Number: CGBS4018
Manufacturer
Eaton Crouse-Hinds
Part number
CGBS4018

Quick Summary

The Eaton Crouse-Hinds CGBS4018 portable cord connector is a reliable explosion-proof solution for hazardous-location electrical feeds. In the field, choosing the wrong connector can lead to downtime, unsealed joints, and safety incidents. This model is NEC/CEC compliant and carries hazardous-location ratings including Class I Division 1; Class II Division 1 and 2; and Class III, supporting safe, code-conforming installations. Designed for non-armoured cables and rugged environments, it enables faster field assembly and longer service life, reducing maintenance costs. For engineers and procurement teams, the CGBS4018 delivers predictable performance and a dependable path to project completion.

Product Information

Extended Description

CGBS4018 Eaton Crouse-Hinds: Eaton Crouse-Hinds series CGBS portable cord connector, Non-armoured cable, Steel, Outer sheath min/max: 0.875-1.000", Explosionproof, 1-1/4" NPT
Product Name
Eaton Crouse-Hinds series CGBS portable cord connector
Catalog Number
CGBS4018
Product Length/Depth
3.5 in
Product Height
1.25 in
Product Width
1.25 in
Product Weight
1.3 lb
UPC
782274142906
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1 Class II, Division 2 Class III
Protection type
Explosion-proof
Cable type
Non-armoured
Gland type
Portable cord connector
Thread Size
1-1/4"
Thread type
NPT
Outer sheath (min/max)
0.875-1.000"
Material
Steel
Explosion-proof steel housing provides robust protection for connectors operating in hazardous locations, delivering consistent performance where ignition sources must be controlled. The CGBS4018 is designed for NEC/CEC compliance and hazardous-area ratings, reducing the risk of noncompliant assemblies that can trigger audits. By integrating a rugged gland interface and proven sealing practices, this cord connector supports safe, long-term operation in Class I Division 1, Class II Division 1, and Class III environments. With a 1-1/4" NPT gland, the CGBS4018 integrates with standard conduit fittings, enabling fast, reliable field installation and fewer leak paths. The secure connection minimizes maintenance loops and vibration-related wear, translating to lower total cost of ownership in demanding plants. This feature also helps ensure leak-tight performance when used with non-armoured cables. Non-armoured cable compatibility keeps inventory simple and reduces cabling costs, while maintaining appropriate protection for controlled environments. The connector's threads and housing are engineered for quick alignment and tight tolerances, which cut installation time during commissioning. For projects with mixed cable types, the CGBS4018 provides a dependable option in a single part number. Compact dimensions—3.5 inches long, 1.25 inches high and wide—combine with a light 1.3-pound weight to ease handling and panel packing. This form factor supports install-in-tight-spaces scenarios common in plant basements, switchgear rooms, and offshore platforms. The combination of size, weight, and steel construction yields real-world throughput gains for installers. Beyond hardware, the unit carries NEC hazardous ratings and Class I/II/III area classifications, ensuring you meet regulatory requirements while documenting compliance for audits. The CGBS4018's non-armoured, explosion-proof design offers a safe, durable solution that can reduce downtime by minimizing rework and resealing needs during refurbishments.

Get a Quick Quote for a Eaton Crouse-Hinds CGBS4018

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds CGBS4018? Enquire Now

FAQs

Ensure enclosure and conduit sizes meet the 1-1/4" NPT gland requirements, verify the outer sheath range of 0.875–1.000 inches, and confirm the use of non-armoured cable. Follow recommended torque and sealing procedures, use appropriate thread sealant, and verify the connection remains leak-tight during commissioning to prevent ingress and ignition risks.
The CGBS4018 carries NEC/CEC compliance with Class I Division 1, Class II Division 1, Class II Division 2, and Class III ratings. This combination ensures protection and documentation for installations in hazardous locations, enabling safe operation and simplified regulatory acceptance.
Yes. The connector is designed for non-armoured cables and hazardous-location environments, offering explosion-proof protection and reliable seals. For oil & gas facilities, it supports compliant terminations in Class I Division 1 and related classifications, while simplifying maintenance and field upgrades due to its durable steel construction.
The CGBS4018 complies with NEC/CEC standards and is suitable for Hazardous/Classified Locations. It supports area classifications including Class I Division 1, Class II Division 1 and 2, and Class III, ensuring alignment with regulatory documentation and audit readiness for industrial facilities.
The combination of a fast field-installation design, robust explosion-proof housing, and non-armoured cable compatibility minimizes rework and resealing needs. Its standard 1-1/4" NPT gland and compact form reduce installation time, while NEC/CEC compliance lowers regulatory risk, delivering lower total cost of ownership over the life of the installation.