Eaton Crouse-Hinds CGE295 SG cable gland - NEMA 4

Part Number: CGE295 SG
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
CGE295 SG

Quick Summary

The CGE295 SG cable gland from Eaton Crouse-Hinds delivers a robust, 90‑degree termination for non-armoured tray cables in control panels and industrial enclosures. Field installations often struggle with sealing integrity, space constraints, and misfit parts; this gland addresses those issues with a sealed gasket, locknut, and precise 3/4" NPT threads. It meets NEC/CEC standards and is suitable for Ordinary/Non-Hazardous Locations, providing dependable protection in everyday wiring. With its compact footprint and general‑purpose performance, it supports faster installs, reduces rework, and improves reliability for mass‑produced assemblies while staying fully compatible with the CGE gland family and standard stocking practices.

Product Information

Extended Description

CGE295 SG Eaton Crouse-Hinds: Eaton Crouse-Hinds series CGE cable gland, Cable range min/max: 0.500-0.625", Non-armoured and tray cable, 90° angle, Non-armoured gland, Feraloy iron alloy, General purpose, Sealing gasket and locknut, 3/4" NPT
Product Name
Eaton Crouse-Hinds series CGE cable gland
Catalog Number
CGE295 SG
Product Length/Depth
2.32 in
Product Height
1.14 in
Product Width
1.14 in
Product Weight
0.44 lb
UPC
782274131818
Area classification
Ordinary/Non-Hazardous Locations
Standards type
NEC/CEC
NEMA Rating
4
Protection type
General purpose
Cable type
Tray cable Non-armoured
Gland type
Non-armoured
Connector type
90° angle
Thread Size
3/4"
Thread type
NPT
Cable range (min/max)
0.500-0.625"
Material
Feraloy iron alloy
Special features
Sealing gasket and locknut
Feature 90° angle gland with a 3/4" NPT thread enables compact terminations in crowded enclosures. Business Impact Reduces cabinet depth requirements and simplifies cable routing, lowering installation time and field rework. Application Ideal for control panels and equipment enclosures where space is at a premium. Feature Cable range 0.500-0.625" for tray cables and non-armoured construction. Business Impact Supports common tray cable sizes with a single gland, reducing SKUs and simplifying procurement. Application Suited for non-armoured tray cable installations in general purpose wiring. Feature Feraloy iron alloy body delivers rugged mechanical strength. Business Impact Improves resistance to impact and wear in harsh environments, extending service life. Application Fits general purpose electrical installations in industrial settings. Feature Sealing gasket and locknut provide a secure seal. Business Impact Delivers reliable ingress protection and faster field assembly, reducing maintenance calls. Application Beneficial in installations requiring dependable sealing of cable entries. Feature NEC/CEC compliance and NEMA 4 rating. Business Impact Ensures code conformity and enclosure protection in ordinary locations, mitigating regulatory risk. Application Suitable for non-hazardous areas where standard enclosures are used. Feature Compatible with the CGE family and available installation resources. Business Impact Streamlines stocking and maintenance with familiar components; installation can leverage IF 1826 instructions. Application Ideal for panel builders and OEMs integrating CGE glands into existing CGE workflows.

Get a Quick Quote for a Eaton Crouse-Hinds CGE295 SG

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds CGE295 SG? Enquire Now

FAQs

The CGE295 SG is designed for non-armoured tray cables with a 0.500–0.625 inch range and uses a 3/4 inch NPT gland. It features a 90° angle for compact terminations and includes a sealing gasket plus locknut. It is part of the CGE family, ensuring compatibility with other non-armoured CGE glands in standard panel builds.
This gland carries a NEMA 4 rating and complies with NEC/CEC standards, making it suitable for Ordinary/Non-Hazardous Locations. These certifications help ensure enclosure protection against dust, water ingress, and general electrical safety in non-hazardous industrial environments.
The CGE295 SG is intended for Ordinary/Non-Hazardous Locations and is not designed for outdoor exposure or hazardous environments. For outdoor or hazardous-area needs, consider glands with higher protection levels or explosion‑proof variants and consult the installation guidelines.
Support materials include a Crouse-Hinds tray cable glands brochure, catalog pages for CGE/CGD/CGB, UL certification reports for non-armoured CGE glands, and installation sheets IF 1826. UL listings are available for US and Canada, and installation datasheets provide guidance on gasket, locknut use, and torque values.
Key resources include IF 1826 installation sheets, the CGE catalog page, and the CGE295 SG specification sheet. These documents cover gasket installation, gland torque, cable range compatibility, thread sizing, and neck-down considerations, enabling faster, more reliable field assemblies and easier maintenance in ongoing operations.