Eaton CPS12022 Condulet CPS Outlet Box - Hazardous Locations

Part Number: CPS12022
Manufacturer
Eaton Crouse-Hinds
Part number
CPS12022

Quick Summary

CPS12022 Condulet CPS conduit outlet box provides rugged enclosure for hazardous-location wiring in industrial facilities. Installers often battle moisture infiltration, conduit misalignment, and non-compliant boxes in harsh environments—this unit mitigates those risks with tight seals and solid construction. Certified for NEC/CEC compliance and hazardous-location usage, including Class I and Class II ratings across Division 1 and 2, plus Class III where applicable. Designed to streamline procurement, it supports 1/2 in and 3/4 in trade sizes and ships with a 3/4 in hub cover, delivering consistency and long-term value across projects.

Product Information

Extended Description

CPS12022 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet CPS conduit outlet box with hub cover, 3/4" cover size, Feraloy iron alloy, 1/2" and 3/4" trade size
Product Name
Eaton Crouse-Hinds series Condulet CPS conduit outlet box with hub cover
Catalog Number
CPS12022
Product Length/Depth
6.31 in
Product Height
4.63 in
Product Width
3.87 in
Product Weight
8.18 lb
UPC
782274094601
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
Trade size
1/2" and 3/4"
Cover size
3/4"
Material
Feraloy iron alloy
Feature: Feraloy iron alloy construction provides superior impact resistance and structural integrity in demanding environments. Business Impact: Reduced risk of enclosure damage during installation and operation, leading to lower maintenance costs over the life of the system. Application: Ideal for heavy-industrial sites where physical protection and long service life matter. Feature: 1/2 in and 3/4 in trade sizes with a 3/4 in hub cover simplifies conduit planning and stocking. Business Impact: Faster field setup and fewer part mismatches, improving project timelines and total cost of ownership. Application: Common in automation panels and process control cabinets in hazardous areas. Feature: NEC/CEC compliance with Hazardous/Classified Locations ratings (Class I, II, III; Divisions 1 and 2). Business Impact: Regulatory risk reduction and easier permit acquisition. Application: Critical for oil & gas, chemical processing, and heavy manufacturing. Feature: Robust enclosure dimensions (6.31 in L × 4.63 in H × 3.87 in W) and weight (8.18 lb) provide predictable fitment in standard rack layouts. Business Impact: Accurate planning and consistent mounting across sites. Application: Retrofit and new-build projects where enclosure footprint matches existing layouts. Feature: Hub cover compatibility and catalog alignment with Eaton CPS data (spec sheet and catalog page). Business Impact: Streamlined procurement, fewer compatibility questions, and reliable supply chain. Application: Procurement for multiple facilities and ongoing maintenance programs. Objection addressed: Some buyers worry about weight; the solution is that the compact yet strong Feraloy alloy offers durable protection without excessive bulk, and the unit remains straightforward to install using standard mounting practices.

Get a Quick Quote for a Eaton Crouse-Hinds CPS12022

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds CPS12022? Enquire Now

FAQs

CPS12022 supports 1/2 in and 3/4 in trade size conduits and includes a hub cover, enabling straightforward installation in standard conduit runs. Plan for the box footprint (6.31 in L × 4.63 in H × 3.87 in W) and ensure mounting points align with your panel or enclosure. Refer to the Eaton CPS specification sheet for mounting guidelines and recommended hardware.
CPS12022 is listed under NEC/CEC standards with Hazardous/Classified Locations ratings, including Class I, Division 1 and 2, Class II Division 1 and 2, and Class III. This translates to compliance for hazardous-area installations and helps you meet permit and safety requirements. UL certification materials further support explosion-proof expectations for relevant applications.
Yes. CPS12022 is documented in UL-certified CPS Conduit Outlet Boxes materials for hazardous locations, including explosion-protection considerations. For specific approval, consult the UL certification page referenced in Eaton’s technical materials to confirm project-specific applicability and mounting requirements.
Key specs include a length/depth of 6.31 in, height of 4.63 in, width of 3.87 in, and a weight of 8.18 lb. It supports 1/2 in and 3/4 in trade sizes and uses a 3/4 in hub cover. These dimensions help with space planning and ensure compatibility with nearby enclosures and mounting surfaces.
Access the Eaton CPS12022 specification sheet at Eaton’s site and the CPS Conduit Outlet Boxes catalog page for full product details. Additional technical references include the explosion-proof UL certification page for Condulet CPS and the Industrial Fittings Bend Radius and Cubic Capacity Chart, which aid in integration planning and safe routing.