Eaton CPS152 101 Receptacle Assembly - Explosionproof

Part Number: CPS152 101
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
CPS152 101

Quick Summary

The Eaton CPS152 101 receptacle assembly provides explosionproof electrical connections for hazardous locations. In challenging plant environments, safety and sealing integrity are critical; a factory-sealed back box reduces ingress, corrosion, and downtime. The unit meets NEC/CEC standards, is UL-listed for hazardous locations, and carries Hazardous/Classified Location area classifications (Class I, Division 1 and 2). With a 20 A rating, two-wire, three-pole configuration and copper-free aluminum housing, it enables fast, compliant wiring in single-gang Arktite CPS installations for industrial automation and hazardous-area control panels. This combination supports reliable operation, simplified maintenance, and consistent compliance across your production line. Engineers appreciate the straightforward mounting and proven performance in harsh environments.

Product Information

Extended Description

CPS152 101 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Arktite CPS receptacle assembly, 20A, Dead end, Two-wire, three-pole, Brass contacts, 60 Hz, Style 2, 1 HP, Copper-free alum, Single-gang, Factory sealed, 1/2", Delayed action circuit breaking, 125-250 Vac/18 Vdc
Product Name
Eaton Crouse-Hinds series Arktite CPS receptacle assembly
Catalog Number
CPS152 101
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
8 in
Product Weight
6.6 lb
UPC
782274181004
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2
Grounding style
Style 2
Number of gangs
Single-gang
Amperage Rating
20A
Configuration
Two-wire, three-pole
Back box style
Dead end
Trade size
1/2"
Voltage rating
125-250 Vac/18 Vdc
Horsepower
1 hp
Frequency rating
60 Hz
Material
Copper-free aluminum
Contact material
Brass
Special features
Factory sealed
Type
Delayed action circuit breaking
Explosionproof construction with a copper-free aluminum housing and brass contacts enhances operator safety and enclosure integrity in hazardous locations. This design translates into lower ignition risk, improved fault tolerance, and easier regulatory compliance, reducing the probability of unplanned downtime. It is well-suited for Class I Division 1 environments in chemical plants, oil refineries, and other high-risk facilities where reliable connectors power critical automation. Factory-sealed construction and a rugged dead-end-style back box minimize ingress of dust, water, and corrosive vapors, extending component life and reducing maintenance cycles. The result is lower maintenance costs and fewer field service visits, even in washdown-heavy environments. For OEMs and integrators, this translates into flatter maintenance budgets and fewer unexpected outages. High-current compatibility and flexible voltage ratings enable broad application across motors, sensors, and controls. The CPS152 101 supports 20 A at 125-250 Vac or 18 Vdc, with 60 Hz operation and a 1 HP horsepower rating, enabling direct control of typical automation devices without additional adapters. This simplifies panel design, reduces wiring complexity, and improves overall system efficiency in industrial automation. Style 2 grounding and a dead-end back box simplify grounding and termination in compact, single-gang footprints. The 1/2 inch trade size aligns with standard conduit fittings, speeding installation and reducing miswiring risks. These attributes improve field reliability and enable faster commissioning in hazardous-location panels, especially when integrating legacy equipment with new Arktite CPS receptacles. Certified for NEC/CEC, UL hazardous locations, and area classifications Class I Division 1 and 2, the CPS152 101 streamlines regulatory approvals and audits for new and retrofit projects. OEMs benefit from plug-and-play compatibility with the Arktite CPS ecosystem, while end-users gain confidence that installations meet industry requirements and performance expectations under demanding conditions. This combination supports faster start-ups and long-term reliability across industrial automation deployments.

Get a Quick Quote for a Eaton Crouse-Hinds CPS152 101

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds CPS152 101? Enquire Now

FAQs

Yes. The CPS152 101 is designed for a 1/2 inch trade size and a single-gang footprint with a dead-end back box, enabling straightforward compatibility with common conduit fittings and existing enclosures. This reduces rework and speeds up commissioning in hazardous-location installations.
The receptacle supports 20A at 125-250 Vac and 18 Vdc, operates at 60 Hz, and has a 1 HP rating. It uses brass contact material in a copper-free aluminum housing, providing reliable performance for motors and control circuits in industrial automation.
This receptacle is ideal for Class I Division 1 and 2 hazardous locations such as chemical plants, oil refineries, and other environments requiring explosionproof, factory-sealed connections in single-gang installations for control panels and enclosures.
CPS152 101 carries NEC/CEC compliance and UL hazardous-location certifications with Class I Division 1 and 2 area classifications, ensuring regulatory acceptance for new builds and retrofit projects in hazardous-location facilities.
The factory-sealed design minimizes ingress of dust, water, and corrosive vapors, reducing maintenance frequency and prolonging component life. This leads to lower maintenance costs, fewer field visits, and more reliable uptime for critical automation systems.