Eaton CPS152 102 receptacle assembly - Hazardous Locations

Part Number: CPS152 102
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
CPS152 102

Quick Summary

Eaton CPS152 102 receptacle assembly is a rugged, explosion-protected power connection designed for hazardous locations. Maintenance downtime and field retrofit challenges in harsh zones often slow repairs and raise safety risk. This unit carries NEC/CEC approvals with Class I, Division 1 and Division 2 ratings, making it suitable for hazardous environments. Copper-free aluminum construction paired with brass contacts delivers durable, corrosion-resistant performance while meeting safety and compliance demands. Designed for two-gang, 1/2-inch trade size power distribution with factory sealing, it integrates into automation panels, improving installation efficiency and uptime. For system integrators, this reduces spare parts variety and accelerates maintenance with a common Arktite CPS family.

Product Information

Extended Description

CPS152 102 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Arktite CPS receptacle assembly, 20A, Dead end, Two-wire, three-pole, Brass contacts, 60 Hz, Style 2, 1 HP, Copper-free alum, Two-gang, Factory sealed, 1/2", Delayed action circuit breaking, 125-250 Vac/18 Vdc
Product Name
Eaton Crouse-Hinds series Arktite CPS receptacle assembly
Catalog Number
CPS152 102
Product Length/Depth
7.19 in
Product Height
6.72 in
Product Width
8 in
Product Weight
13.55 lb
UPC
782274181103
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2
Grounding style
Style 2
Number of gangs
Two-gang
Amperage Rating
20A
Configuration
Two-wire, three-pole
Back box style
Dead end
Trade size
1/2"
Voltage rating
125-250 Vac/18 Vdc
Horsepower
1 hp
Frequency rating
60 Hz
Material
Copper-free aluminum
Contact material
Brass
Special features
Factory sealed
Type
Delayed action circuit breaking
Deliberate action: Delayed action circuit breaking is built into the CPS152 102, delivering safer disconnection during overload or fault conditions. This reduces arc flash exposure and extends hardware life, minimizing unplanned downtime in critical automation loops. This is particularly valuable in high-induction loads and motors found in processing lines where a sudden trip can halt production.Robust enclosure and grounding: Two-gang, dead-end back box design with Style 2 grounding provides a secure and compliant mounting footprint in compact installations, simplifying field wiring and reducing enclosure modification time for hazardous-area panels. This supports reliable power distribution in confined spaces and supports standardized CPS family installations.Electrical performance clarity: Rated for 20A, 125-250 Vac / 18 Vdc with 60 Hz operation, and 1 HP capabilities, this receptacle handles essential plant loads while leaving headroom for startup surges common in conveyors, pumps, and fans in harsh environments. This helps minimize nuisance outages and improve process uptime.Material and corrosion resilience: Copper-free aluminum housing paired with brass contacts delivers long-term durability in corrosive environments, reducing maintenance cycles and replacement costs, which is especially beneficial for chemical processing and oil/gas facilities. This combination also supports reliable conductivity under varying ambient conditions.Factory sealed and certified: Factory sealing guards against dust and moisture ingress, ensuring performance in explosion-protected installations and meeting hazardous-location requirements. The sealed design complements the Class I Division 1 and Division 2 ratings, allowing dependable operation in challenging plant atmospheres.Installation compatibility and scalability: With a 1/2" trade size and a two-gang footprint, the CPS152 102 aligns with standard conduit and mounting schemes, enabling quick retrofits and straightforward integration into Arktite CPS, CPP, CPS-themed upgrade programs. This reduces commissioning time when expanding hazardous-location wiring devices across facilities.

Get a Quick Quote for a Eaton Crouse-Hinds CPS152 102

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds CPS152 102? Enquire Now

FAQs

When installing the CPS152 102 in hazardous locations, plan for a dead-end back box to minimize enclosure modifications. Use appropriate glands and seals to maintain the factory seal and preserve explosion-protected ratings. Ensure mounting aligns with the two-gang footprint and 1/2 inch trade size, and verify Class I, Division 1/Division 2 compatibility with your area classification before connection.
The CPS152 102 provides 20A current capability, with a voltage rating of 125-250 Vac / 18 Vdc and a frequency of 60 Hz. It supports two-wire, three-pole configurations and is rated for up to 1 horsepower. This combination covers typical hazardous-location motor and control circuits found in automation panels, reducing the need for multiple device variants.
Yes. The CPS152 102 is designed for two-wire, three-pole configurations and carries NEC/CEC approvals with Class I, Division 1 and Division 2 ratings. This makes it appropriate for hazardous-area installations where both high-integrity grounding and reliable fault disconnection are critical, such as in chemical processing or oil and gas facilities.
Key certifications include NEC/CEC standards with Class I, Division 1 and Division 2 ratings and Hazardous/Classified Locations area classification. These certifications validate safe operation in flammable atmospheres, support compliance with industry regulations, and enable installation in regulated facilities without requiring additional adapters or risk assessments for individual components.
The copper-free aluminum housing and brass contacts provide corrosion resistance and durable electrical performance, reducing maintenance frequency in harsh environments. Factory sealing minimizes ingress, lowering the risk of field contamination. Plan for standard lifecycle replacement in high-duty applications and maintain an existing stock of Arktite CPS compatible components to simplify spares and reduce downtime.