Eaton Crouse-Hinds CPS152 312 Receptacle Assembly - Hazardous/Classified Locations

Part Number: CPS152 312
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
CPS152 312

Quick Summary

Eaton Crouse-Hinds CPS152 312 receptacle assembly delivers safe, explosionproof power connections for hazardous locations. Engineers often struggle with reliable through-feed outlets in classified areas, facing sealing gaps, grounding challenges, and difficult maintenance. This unit carries NEC/CEC compliance and UL certification with Class I, Division 1 and Division 2 ratings, plus a factory-sealed design for rugged service. With two-gang construction, copper-free aluminum housing, and a 1" trade size, it enables fast, compliant installations and long service life in demanding environments. Manufacturers benefit from reduced downtime due to factory sealed construction and standardized mounting in two-gang back boxes, simplifying audits across mining, chemical processing, and oil & gas applications.

Product Information

Extended Description

CPS152 312 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Arktite CPS receptacle assembly, 20A, Through feed, Two-wire, three-pole, Brass contacts, 60 Hz, Style 2, 1 HP, Copper-free alum, Two-gang, Factory sealed, 1", Delayed action circuit breaking, 125-250 Vac/18 Vdc
Product Name
Eaton Crouse-Hinds series Arktite CPS receptacle assembly
Catalog Number
CPS152 312
Product Length/Depth
7.19 in
Product Height
6.72 in
Product Width
8 in
Product Weight
13.37 lb
UPC
782274182100
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2
Grounding style
Style 2
Number of gangs
Two-gang
Amperage Rating
20A
Configuration
Two-wire, three-pole
Back box style
Through feed
Trade size
1"
Voltage rating
125-250 Vac/18 Vdc
Horsepower
1 hp
Frequency rating
60 Hz
Material
Copper-free aluminum
Contact material
Brass
Special features
Factory sealed
Type
Delayed action circuit breaking
Through-feed back box style and two-gang construction streamline field wiring and enclosure integration, reducing conduit runs and on-site labor. This yields faster installation, lower total installed cost, and predictable performance for industrial power distribution in hazardous locations. The CPS152 312 is designed to work with standard Arktite CPS back boxes, supporting reliable mounting in chemical plants, oil refineries, and mining facilities. High amperage rating and broad voltage coverage provide flexibility to support both AC and DC loads from a single unit, simplifying panel design and stocking for 125-250 VAC / 18 VDC at 60 Hz. This reduces part counts and maintenance, and enables safer control circuits and motors in demanding environments. Copper-free aluminum housing paired with brass contacts delivers corrosion resistance and lighter weight, translating to easier handling, improved reliability, and lower lifecycle costs in harsh chemical, coastal, or industrial settings. Factory sealed construction minimizes ingress of dust and moisture, lowering maintenance and extending service life in explosive environments, while the delayed action circuit breaking feature enhances fault isolation during startups. The two-wire, three-pole configuration, Style 2 grounding, and 1" trade size simplify compatibility with existing Arktite CPS infrastructure, speeding procurement and field service while ensuring NEC/CEC compliance across a wide range of hazardous-location installations.

Get a Quick Quote for a Eaton Crouse-Hinds CPS152 312

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds CPS152 312? Enquire Now

FAQs

When installing CPS152 312, verify Class I, Division 1 or Division 2 suitability and use approved through-feed back boxes. Ensure proper grounding with Style 2 and confirm 1" trade size fits the enclosure. Plan wiring routes to minimize ingress potential and follow NEC/CEC guidelines for hazardous locations to maintain compliance and safety.
Yes. CPS152 312 is designed to meet NEC/CEC requirements for hazardous locations and carries UL certification, including classifications for Class I, Division 1 and Division 2 environments. This alignment supports regulatory acceptance, easier audits, and safer operation in mining, chemical processing, and oil & gas facilities.
Absolutely. CPS152 312 supports 125-250 VAC and 18 VDC at 60 Hz, delivering flexibility for mixed power environments. This allows the same receptacle to power diverse equipment such as motors, sensors, and control circuits, reducing part variety and simplifying stock management on hazardous-location projects.
Yes. The two-gang configuration and through-feed back box style are built to integrate with standard Arktite CPS infrastructure. This compatibility accelerates field wiring, ensures reliable mounting, and reduces installation complexity on complex hazardous-location projects, while preserving compliance with industry standards.
The factory-sealed design minimizes ingress of dust, moisture, and contaminants, lowering maintenance needs and extending service life in harsh environments. Coupled with robust copper-free aluminum housing and brass contacts, it offers long-term reliability, reduced downtime, and lower lifecycle costs for continuous operation in mining, chemical processing, and oil & gas facilities.