Quick Summary

Eaton CPS532 212 Receptacle Assembly provides explosion-proof power connections for hazardous-location control panels. In harsh industrial environments, maintaining sealing integrity and regulatory compliance is a constant challenge for designers and technicians. It meets NEC/CEC hazardous-location standards with Class I, Division 1 and Division 2 ratings and UL certifications for use in hazardous locations. As part of the Arktite CPS line, the two-gang, through-feed assembly uses copper-free aluminum housing and brass contacts to withstand corrosive atmospheres while maintaining electrical performance. Its factory-sealed construction simplifies installation, improves uptime, and lowers maintenance costs, enabling safer, more compliant operation in critical processes.

Product Information

Extended Description

CPS532 212 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Arktite CPS receptacle assembly, 7A/30A, Through feed, Two-wire, three-pole, Brass contacts, 60 Hz, Style 2, 0.5 HP/1.5 HP, Copper-free alum, 2-gang, Fact seal, 3/4", Delay action circuit brk, 125-250 Vac/480 Vac
Product Name
Eaton Crouse-Hinds series Arktite CPS receptacle assembly
Catalog Number
CPS532 212
Product Length/Depth
7.19 in
Product Height
6.72 in
Product Width
7.25 in
Product Weight
14.28 lb
UPC
782274184401
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2
Grounding style
Style 2
Number of gangs
Two-gang
Amperage Rating
7A/30A
Configuration
Two-wire, three-pole
Back box style
Through feed
Trade size
3/4"
Voltage rating
125-250 Vac/480 Vac
Horsepower
0.50 hp, 1.50 hp
Frequency rating
60 Hz
Material
Copper-free aluminum
Contact material
Brass
Special features
Factory sealed
Type
Delayed action circuit breaking
Copper-free aluminum housing with brass contacts provides robust corrosion resistance and dependable current transfer in harsh environments. This combination reduces maintenance and extends service life for explosion-proof receptacles deployed in chemical plants, refineries, and other hazardous locations. The CPS532 212 is designed for two-wire, three-pole CPS configurations within the Arktite CPS line, delivering reliable performance in demanding process environments. Two-gang, through-feed back box design streamlines installation by minimizing field modifications and wiring runs. The through-feed configuration simplifies cable management and reduces installation time, helping project teams meet tight commissioning windows without sacrificing seal integrity. The unit's copper-free aluminum housing and factory seal support durability where ingress protection and containment matter most. With a 3/4 inch trade size and a voltage window of 125-250 Vac or 480 Vac at 60 Hz, this receptacle covers diverse industrial loads and control circuits. The 7A/30A amperage range accommodates light-to-medium duty applications, including motor-starter circuits and process instrumentation, while the 0.5 hp/1.5 hp horsepower ratings reflect practical performance limits. Integrating with two-wire, three-pole systems keeps wiring simple and maintenance predictable. Factory-sealed construction pairs with delay-action circuit breaking (Style 2 grounding) to minimize exposure to dust, moisture, and fault-induced trips. This design philosophy translates to higher uptime, fewer unplanned outages, and easier regulatory inspections in hazardous locations. Compatibility with through-feed back boxes and standard 3/4 inch openings simplifies retrofits and new installations alike. Compliance is built in, with NEC/CEC standards supporting Class I, Division 1 and 2 classifications for hazardous areas and UL certification details referenced in the documentation. This ensures that installation teams can spec confidently for oil-and-gas, chemical processing, and other process industries. In total, the CPS532 212 delivers a robust, future-ready solution for industrial automation environments.

Get a Quick Quote for a Eaton Crouse-Hinds CPS532 212

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds CPS532 212? Enquire Now

FAQs

For hazardous locations, verify Class I, Division 1/2 suitability, ensure a through-feed back box alignment with a 3/4 inch opening, and follow IF165 installation sheets. The CPS532 212 uses a two-gang configuration with factory seals to minimize ingress and simplify wiring during retrofit projects.
The receptacle assembly is designed to satisfy NEC/CEC hazardous-location requirements with Class I, Division 1 and 2 ratings and is UL-certified for use in hazardous locations. Refer to UL certification pages for Canada and general compliance details to back regulatory acceptance.
Yes. The 3/4 inch trade size and through-feed back box style align with standard installation practices, enabling straightforward retrofit into existing enclosures and simple new installations without sacrificing seal integrity or wiring practicality.
Through-feed wiring reduces field cabinet modifications while the factory-sealed design minimizes dust and moisture ingress. The delayed action circuit breaking and Style 2 grounding further protect circuits from faults and corrosion in hazardous environments.
Choosing CPS532 212 reduces maintenance trips due to corrosion resistance, lowers installation time with a two-gang through-feed design, and improves uptime in hazardous locations. Regulatory compliance and UL-listed certification support easier inspections and longer service intervals.