Eaton CPS532 212 Receptacle Assembly - Hazardous Locations
Part Number: CPS532 212
Quick Summary
Eaton CPS532 212 Receptacle Assembly provides explosion-proof power connections for hazardous-location control panels. In harsh industrial environments, maintaining sealing integrity and regulatory compliance is a constant challenge for designers and technicians. It meets NEC/CEC hazardous-location standards with Class I, Division 1 and Division 2 ratings and UL certifications for use in hazardous locations. As part of the Arktite CPS line, the two-gang, through-feed assembly uses copper-free aluminum housing and brass contacts to withstand corrosive atmospheres while maintaining electrical performance. Its factory-sealed construction simplifies installation, improves uptime, and lowers maintenance costs, enabling safer, more compliant operation in critical processes.
Product Information
Extended Description
CPS532 212 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Arktite CPS receptacle assembly, 7A/30A, Through feed, Two-wire, three-pole, Brass contacts, 60 Hz, Style 2, 0.5 HP/1.5 HP, Copper-free alum, 2-gang, Fact seal, 3/4", Delay action circuit brk, 125-250 Vac/480 Vac
Product Name
Eaton Crouse-Hinds series Arktite CPS receptacle assembly
Catalog Number
CPS532 212
Product Length/Depth
7.19 in
Product Height
6.72 in
Product Width
7.25 in
Product Weight
14.28 lb
UPC
782274184401
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2
Grounding style
Style 2
Number of gangs
Two-gang
Amperage Rating
7A/30A
Configuration
Two-wire, three-pole
Back box style
Through feed
Trade size
3/4"
Voltage rating
125-250 Vac/480 Vac
Horsepower
0.50 hp, 1.50 hp
Frequency rating
60 Hz
Material
Copper-free aluminum
Contact material
Brass
Special features
Factory sealed
Type
Delayed action circuit breaking
Arktite CPS, CPP and CPR Explosionproof Receptacles and Plugs catalog page
Arktite CPS, CPP, CPR Explosionproof Receptacles, Plugs and Connectors UL certification
Arktite CPS, CPP, CPR Explosionproof Receptacles, Plugs and Connectors UL certification
IF 165 - CPS Receptacles
IF 165 - CPS Receptacles
Eaton Specification Sheet - CPS532 212
Copper-free aluminum housing with brass contacts provides robust corrosion resistance and dependable current transfer in harsh environments. This combination reduces maintenance and extends service life for explosion-proof receptacles deployed in chemical plants, refineries, and other hazardous locations. The CPS532 212 is designed for two-wire, three-pole CPS configurations within the Arktite CPS line, delivering reliable performance in demanding process environments. Two-gang, through-feed back box design streamlines installation by minimizing field modifications and wiring runs. The through-feed configuration simplifies cable management and reduces installation time, helping project teams meet tight commissioning windows without sacrificing seal integrity. The unit's copper-free aluminum housing and factory seal support durability where ingress protection and containment matter most. With a 3/4 inch trade size and a voltage window of 125-250 Vac or 480 Vac at 60 Hz, this receptacle covers diverse industrial loads and control circuits. The 7A/30A amperage range accommodates light-to-medium duty applications, including motor-starter circuits and process instrumentation, while the 0.5 hp/1.5 hp horsepower ratings reflect practical performance limits. Integrating with two-wire, three-pole systems keeps wiring simple and maintenance predictable. Factory-sealed construction pairs with delay-action circuit breaking (Style 2 grounding) to minimize exposure to dust, moisture, and fault-induced trips. This design philosophy translates to higher uptime, fewer unplanned outages, and easier regulatory inspections in hazardous locations. Compatibility with through-feed back boxes and standard 3/4 inch openings simplifies retrofits and new installations alike. Compliance is built in, with NEC/CEC standards supporting Class I, Division 1 and 2 classifications for hazardous areas and UL certification details referenced in the documentation. This ensures that installation teams can spec confidently for oil-and-gas, chemical processing, and other process industries. In total, the CPS532 212 delivers a robust, future-ready solution for industrial automation environments.
Get a Quick Quote for a Eaton Crouse-Hinds CPS532 212
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds CPS532 212?
Enquire Now
FAQs
For hazardous locations, verify Class I, Division 1/2 suitability, ensure a through-feed back box alignment with a 3/4 inch opening, and follow IF165 installation sheets. The CPS532 212 uses a two-gang configuration with factory seals to minimize ingress and simplify wiring during retrofit projects.
The receptacle assembly is designed to satisfy NEC/CEC hazardous-location requirements with Class I, Division 1 and 2 ratings and is UL-certified for use in hazardous locations. Refer to UL certification pages for Canada and general compliance details to back regulatory acceptance.
Yes. The 3/4 inch trade size and through-feed back box style align with standard installation practices, enabling straightforward retrofit into existing enclosures and simple new installations without sacrificing seal integrity or wiring practicality.
Through-feed wiring reduces field cabinet modifications while the factory-sealed design minimizes dust and moisture ingress. The delayed action circuit breaking and Style 2 grounding further protect circuits from faults and corrosion in hazardous environments.
Choosing CPS532 212 reduces maintenance trips due to corrosion resistance, lowers installation time with a two-gang through-feed design, and improves uptime in hazardous locations. Regulatory compliance and UL-listed certification support easier inspections and longer service intervals.